Abstract
When zenor diode load current is necessary to be controlled by input voltage as a circuit load, existing voltage controlling method cannot be applied to it because the output current of zenor diode is changed due to breakdown voltage variations. We propose input voltage controlled output current source regardless of zenor breakdown voltage variation due to degradation resulted from severe current applied electronic component life test as a circuit load in this paper. We show breakdown voltage characteristics of this zenor diode circuit through simulation, applying adequate values for each component in order to verify the circuit composed of that method, and then show the result in which output current is controlled by input voltage. We confirmed the output current varies proportional to input voltage, and developed circuit shows a constant value independent of zenor diode breakdown voltage variations due to component degradations.
전자회로에서 부하가 제너다이오드일 경우, 입력전압에 의해 부하의 전류를 제어하고자 할 때 제너다이오드의 항복전압 특성에 따라 제어하고자 하는 출력전류가 변하기 때문에 기존의 전압제어 전류 생성 방법을 적용할 수 없다. 이 논문에서는 입력전압을 이용하여 정격치보다 큰 전류를 제너다이오드에 인가하여 부품의 수명시험을 할 때, 제너다이오드가 경년열화에 의하여 항복전압의 특성이 변하여 부하전압이 달라져도 이에 관계없이 동일한 전류를 낼 수 있는 회로를 개발하였다. 이 방법으로 구성된 회로를 실증하기 위해 각 블럭의 부품 값을 적용하고 시뮬레이션 하여 입력전압으로 출력전류를 선형적으로 제어하는 결과를 확인하였다. 결과에 의하면 우리가 측정하고자 하는 항복전압 이상의 입력전압에 대해서 출력전류가 선형적으로 변하며 제너다이오드의 경년열화에 의한 항복전압의 변화와 관계없이 일정한 전류가 흐르는 것을 확인하였다.