DOI QR코드

DOI QR Code

A Study on the Application of EXPERT-CHOICE Technique for Selection of Optimal Decontamination Technology for Nuclear Power Plant of Decommissioning

원전 해체 시 최적 제염기술 선정을 위한 EXPERT-CHOICE 기법 적용에 대한 연구

  • Received : 2017.05.08
  • Accepted : 2017.07.18
  • Published : 2017.09.30

Abstract

The present study researched and analyzed decontamination technology for decommissioning a nuclear power plant. The decision-making technique (EXPERT-CHOICE) was used to evaluate and select the optimal decontamination technology. In principle, this evaluation method is generally performed by a group of experts in the relevant field. The results of the weights were calculated by multiplying the weights with regard to each criterion and evaluation score. The evaluation scores were categorized into 3 ranges (high, medium, and low), and each range was weighted for differentiation. The level of the technology analysis was improved by additionally quantifying the weights with regard to each criterion and subdividing criteria into subcriteria. The basic assumption of the evaluation was that the weight values would decided on in an expert survey and assigned to each criterion. The evaluation criteria followed high weight for the 'High' range. Accordingly, H, M, and L were assigned weights of 10:5:1, respectively. This was based on the EXPERT-CHOICE optimal analysis. The minimum and maximum values were excluded, and the average value was used as the evaluation value for each scenario.

본 논문에서는 원전해체 시 적용 가능한 제염기술을 조사하여 분석하였다. 이를 기반으로 최적의 제염기술을 선정하기 위해 의사결정 기법(EXPERT-CHOICE)을 사용하여 기술성을 평가하였다. 이 평가방법은 해당 분야의 전문가로 이루어진 전문가 집단에 의해 수행되는 것이 일반적이다. 가중치를 고려한 결과는 각 기준에 대한 가중치에 평가점수를 곱한 총합을 구하는 식으로 수행하였다. 평가 점수를 3단계로 하여 High, Medium, Low로 구분한 후 가중치를 부여하여 차별화 시킬 수 있다. 하위분류 기준의 세분화와 각 기준 별 가중치의 추가 정량화를 통하여 기술성 분석의 수준을 제고할 수 있고, 좀 더 설득력 있는 결과의 도출을 예상할 수 있다. 평가의 기본 가정은 각 기준 별 가중치를 전문가 조사에 의해 부여하며, 평가 기준은 High에 좀 더 비중을 주는 식으로 차별화 하였다. 이를 반영하면 H, M, L는 대략 "10:5:1"의 비율로 평가 점수를 부여받는데, 이는 EXPERT-CHOICE 기법의 최적화 분석에 따른 것이다. 최고 및 최저값을 제외한 나머지 결과값의 평균을 평가치로 고려하였다.

Keywords

References

  1. U.S. Environmental Protection Agency (EPA). Technology Reference Guide for Radiologically Contaminated Surfaces, EPA Report, EPA-402-R-06-003 (2006).
  2. J.S. Song, M.Y. Jung, and S.H. Lee, "A Study on the Applicability for Primary System Decontamination through Analysis on NPP Decommission Technology and International Experience", JNFCWT, 14(5), 45-55 (2016).
  3. Hartwig, Ed and Reid, Richard, "Chemical Decontamination at Browns Ferry Unit 1", Nuclear Plant Journal, vol. 21(5), 38-39, ISSN 0892-2055 (2003).
  4. V. Massaut, M. Klein and A. Lefebvre, "Pilot Dismantling of the BR3 Pressurized Water Reactor", ICONE-3: 3. JSME/ASME Joint International Conference on Nuclear Engineering, 1719-1724, Kyoto (1995).
  5. European Commission(EC). Nouvelles Techniques de Decontamination: Gels Chimiques, Electrolyse au Tampon et Abrasifs, EC Report, EUR 13497 (1991).
  6. U.S. Department of Energy(DOE). Concrete Decontamination by Electro-Hydraulic Scabbling, National Energy Technology Laboratory Report, DOE/MC/30164-4000 (1997).
  7. U.S. Department of Energy(DOE). En-vac Robotic Wall Scabbler, Innovative Technology Summary Report, DOE/EM-0578 (2001).
  8. S.S. Shin, S.I. Kim, D.M. Kim, and J.S. Song, "An Analysis on Decontamination Technology for Nuclear Power Plant by using EXPERT-CHOICE", JNFCWT, 14(2), 409-410 (2016).
  9. B.C. Musgrave and R.N. Drake, "Evaluation of Alternative Nonflame Technologies for Destruction of Hazardous Organic Waste", Idaho National Engineering Laboratory, INEL/EXT-97-00123 (1997).

Cited by

  1. 고리 1호기의 잔류방사능 유도농도(DCGL)를 적용한 회색영역 설정과 핵종농도평가 vol.12, pp.3, 2017, https://doi.org/10.7742/jksr.2018.12.3.297