DOI QR코드

DOI QR Code

The Formation of Extragraft Bone Bridging after Anterior Cervical Discectomy and Fusion : A Finite Element Analysis

  • Kwon, Shin Won (Department of Neurosurgery, Seoul National University Hospital) ;
  • Kim, Chi Heon (Department of Neurosurgery, Seoul National University Hospital) ;
  • Chung, Chun Kee (Department of Neurosurgery, Seoul National University Hospital) ;
  • Park, Tae Hyun (Department of Biomedical Engineering, Inje University) ;
  • Woo, Su Heon (Department of Biomedical Engineering, Inje University) ;
  • Lee, Sung-Jae (Department of Biomedical Engineering, Inje University) ;
  • Yang, Seung Heon (Department of Neurosurgery, Seoul National University Hospital)
  • Received : 2017.06.01
  • Accepted : 2017.07.20
  • Published : 2017.11.01

Abstract

Objective : In addition to bone bridging inside a cage or graft (intragraft bone bridging, InGBB), extragraft bone bridging (ExGBB) is commonly observed after anterior cervical discectomy and fusion (ACDF) with a stand-alone cage. However, solid bony fusion without the formation of ExGBB might be a desirable condition. We hypothesized that an insufficient contact area for InGBB might be a causative factor for ExGBB. The objective was to determine the minimal area of InGBB by finite element analysis. Methods : A validated 3-dimensional, nonlinear ligamentous cervical segment (C3-7) finite element model was used. This study simulated a single-level ACDF at C5-6 with a cylindroid interbody graft. The variables were the properties of the incorporated interbody graft (cancellous bone [Young's modulus of 100 or 300 MPa] to cortical bone [10000 MPa]) and the contact area between the vertebra and interbody graft (Graft-area, from 10 to $200mm^2$). Interspinous motion between the flexion and extension models of less than 2 mm was considered solid fusion. Results : The minimal Graft-areas for solid fusion were $190mm^2$, $140mm^2$, and $100mm^2$ with graft properties of 100, 300, and 10000 MPa, respectively. The minimal Graft-areas were generally unobtainable with only the formation of InGBB after the use of a commercial stand-alone cage. Conclusion : ExGBB may be formed to compensate for insufficient InGBB. Although various factors may be involved, solid fusion with less formation of ExGBB may be achieved with refinements in biomaterials, such as the use of osteoinductive cage materials; changes in cage design, such as increasing the area of polyetheretherketone or the inside cage area for bone grafts; or surgical techniques, such as the use of plate/screw systems.

Keywords

References

  1. Buchowski JM, Liu G, Bunmaprasert T, Rose PS, Riew KD : Anterior cervical fusion assessment: surgical exploration versus radiographic evaluation. Spine (Phila Pa 1976) 33 : 1185-1191, 2008 https://doi.org/10.1097/BRS.0b013e318171927c
  2. Chong E, Pelletier MH, Mobbs RJ, Walsh WR : The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review. BMC Musculoskelet Disord 16 : 99, 2015 https://doi.org/10.1186/s12891-015-0546-x
  3. Faizan A, Goel VK, Garfin SR, Bono CM, Serhan H, Biyani A, et al. : Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation. Eur Spine J 21 Suppl 5 : S653-S662, 2012 https://doi.org/10.1007/s00586-009-1211-6
  4. Floyd T, Ohnmeiss D : A meta-analysis of autograft versus allograft in anterior cervical fusion. Eur Spine J 9 : 398-403, 2000 https://doi.org/10.1007/s005860000160
  5. Galbusera F, Bellini CM, Costa F, Assietti R, Fornari M : Anterior cervical fusion: a biomechanical comparison of 4 techniques. Laboratory investigation. J Neurosurg Spine 9 : 444-449, 2008 https://doi.org/10.3171/SPI.2008.9.11.444
  6. Galbusera F, Bellini CM, Raimondi MT, Fornari M, Assietti R : Cervical spine biomechanics following implantation of a disc prosthesis. Med Eng Phys 30 : 1127-1133, 2008 https://doi.org/10.1016/j.medengphy.2008.02.002
  7. Ha SK : Finite element modeling of multi-level cervical spinal segments (C3-C6) and biomechanical analysis of an elastomer-type prosthetic disc. Med Eng Phys 28 : 534-541, 2006 https://doi.org/10.1016/j.medengphy.2005.09.006
  8. Harrison DE, Harrison DD, Cailliet R, Troyanovich SJ, Janik TJ, Holland B : Cobb method or harrison posterior tangent method: which to choose for lateral cervical radiographic analysis. Spine (Phila Pa 1976) 25 : 2072-2078, 2000 https://doi.org/10.1097/00007632-200008150-00011
  9. Heneghan HM, McCabe JP : Use of autologous bone graft in anterior cervical decompression: morbidity & quality of life analysis. BMC Musculoskelet Disord 10 : 158, 2009 https://doi.org/10.1186/1471-2474-10-158
  10. Jung TG, Woo SH, Park KM, Jang JW, Han DW, Lee SJ : Biomechanical behavior of two different cervical total disc replacement designs in relation of concavity of articular surfaces: $ProDisc-C^{(R)}$ vs. $Prestige-LP^{(R)}$. Int J Precis Eng Manuf 14 : 819-824, 2013 https://doi.org/10.1007/s12541-013-0107-x
  11. Kaiser MG, Mummaneni PV, Matz PG, Anderson PA, Groff MW, Heary RF, et al. : Radiographic assessment of cervical subaxial fusion. J Neurosurg Spine 11 : 221-227, 2009 https://doi.org/10.3171/2009.3.SPINE08719
  12. Kim CH, Chung CK, Choi Y, Hwang ST, Kim SM, Park SB : The patientreported outcome of chronic pain after the harvest of anterior iliac bone for anterior cervical arthrodesis. J Clin Neurosci 36 : 102-107, 2017 https://doi.org/10.1016/j.jocn.2016.10.016
  13. Kim CH, Chung CK, Hahn S : Autologous iliac bone graft with anterior plating is advantageous over the stand-alone cage for segmental lordosis in single-level cervical disc disease. Neurosurgery 72 : 257-265; discussion 266, 2013 https://doi.org/10.1227/NEU.0b013e31827b94d4
  14. Kim CH, Chung CK, Jahng TA, Park SB, Sohn S, Lee S : Segmental kyphosis after cervical interbody fusion with stand-alone polyetheretherketone (PEEK) cages: a comparative study on 2 different PEEK cages. J Spinal Disord Tech 28 : E17-E24, 2015 https://doi.org/10.1097/BSD.0000000000000137
  15. Lee SE, Chung CK, Kim CH : Difference in canal encroachment by the fusion mass between anterior cervical discectomy and fusion with bone autograft and anterior plating, and stand-alone cage. J Clin Neurosci 29 : 121-127, 2016 https://doi.org/10.1016/j.jocn.2015.10.039
  16. Mackiewicz A, Banach M, Denisiewicz A, Bedzinski R : Comparative studies of cervical spine anterior stabilization systems - finite element analysis. Clin Biomech (Bristol, Avon) 32 : 72-79, 2016 https://doi.org/10.1016/j.clinbiomech.2015.11.016
  17. Panjabi MM, Crisco JJ, Vasavada A, Oda T, Cholewicki J, Nibu K, et al. : Mechanical properties of the human cervical spine as shown by threedimensional load-displacement curves. Spine (Phila Pa 1976) 26 : 2692-2700, 2001 https://doi.org/10.1097/00007632-200112150-00012
  18. Pechlivanis I, Thuring T, Brenke C, Seiz M, Thome C, Barth M, et al. : Non-fusion rates in anterior cervical discectomy and implantation of empty polyetheretherketone cages. Spine (Phila Pa 1976) 36 : 15-20, 2011 https://doi.org/10.1097/BRS.0b013e3181cbf870
  19. Rhee JM, Chapman JR, Norvell DC, Smith J, Sherry NA, Riew KD : Radiological determination of postoperative cervical fusion: a systematic review. Spine (Phila Pa 1976) 40 : 974-991, 2015 https://doi.org/10.1097/BRS.0000000000000940
  20. Shriver MF, Lewis DJ, Kshettry VR, Rosenbaum BP, Benzel EC, Mroz TE : Pseudoarthrosis rates in anterior cervical discectomy and fusion: a metaanalysis. Spine J 15 : 2016-2027, 2015 https://doi.org/10.1016/j.spinee.2015.05.010
  21. Song J, Taghavi CE, Hsu DW, Song KJ, Song JH, Lee KB : Radiological changes in anterior cervical discectomy and fusion with cage and plate construct: the significance of the anterior spur formation sign. Spine (Phila Pa 1976) 37 : 272-279, 2012 https://doi.org/10.1097/BRS.0b013e31821c3cbf
  22. Song KS, Chaiwat P, Kim HJ, Mesfin A, Park SM, Riew KD : Anterior cervical fusion assessment using reconstructed computed tomographic scans: surgical confirmation of 254 segments. Spine (Phila Pa 1976) 38 : 2171-2177, 2013 https://doi.org/10.1097/BRS.0000000000000017
  23. Song KS, Piyaskulkaew C, Chuntarapas T, Buchowski JM, Kim HJ, Park MS, et al. : Dynamic radiographic criteria for detecting pseudarthrosis following anterior cervical arthrodesis. J Bone Joint Surg Am 96 : 557-563, 2014 https://doi.org/10.2106/JBJS.M.00167
  24. Yoganandan N, Kumaresan S, Pintar FA : Geometric and mechanical properties of human cervical spine ligaments. J Biomech Eng 122 : 623-629, 2000 https://doi.org/10.1115/1.1322034