References
- ASTM (2003), ASTM-C497-03a: Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile, American Society for Testing and Materials.
- ASTM (2016), ASTM-C76-16: Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe, American Society for Testing and Materials.
- Brazilian Association Standards, (2003), NBR 8890: Concrete Pipes for Circular Section for Pluvial Waters and Sanitary Sewers-Requirements and Test Methods, Rio de Janeiro.
- De La Fuente, A., Escariz. R.C., Figueiredo, A.D. and Aguado, A. (2013), "Design of macro-synthetic fibre reinforced concrete pipes", Constr. Build. Mater., 43, 523-532. https://doi.org/10.1016/j.conbuildmat.2013.02.036
- De La Fuente, A., Figueiredo, A.D., Aguado, A., Molins, C. and Chama Neto, P.J. (2011), "Experimentation and numerical simulation of steel fibre reinforced concrete pipes", Mater. Constr., 61(302), 275-288. https://doi.org/10.3989/mc.2010.62810
- European Standards, EN 1916 (2002), Concrete Pipes and Fittings, Unreinforced, Steel Fibre and Reinforced, European Committee for Standardization.
- Haktanir, T., Ari, K., Altun, F. and Karahan, O. (2007), "A comparative experimental investigation of concrete, reinforced-concrete and steel-fibre concrete pipes under three-edge-bearing test", Constr. Build. Mater., 21, 1702-1708. https://doi.org/10.1016/j.conbuildmat.2006.05.031
- Iyer, S., Sinha. S.K., Pedrick, M.K. and Tittmann, B.R. (2012), "Evaluation of ultrasonic inspection and imaging systems for concrete pipes", Automat. Constr., 22, 149-164. https://doi.org/10.1016/j.autcon.2011.06.013
- MacDougall, K., Hoult, N.A. and Moore, I.D. (2016), "Measured load capacity of buried reinforced concrete pipes", ACI Struct. J.
- Mohamed, N., Soliman, A.M. and Nehdi, M.L. (2015), "Mechanical performance of full-scale precast steel fibre-reinforced concrete pipes", Eng. Struct., 84, 287-299. https://doi.org/10.1016/j.engstruct.2014.11.033
- Park, Y., Abolmaali, A., Mohammadagha, M. and Lee, S. (2015), "Structural performance of dry-cast rubberized concrete pipes with steel and synthetic fibers", Constr. Build. Mater., 77, 218-226. https://doi.org/10.1016/j.conbuildmat.2014.12.061
- Peyvandi, A., Soroushian, P. and Jahangirnejad, S. (2013), "Enhancement of the structural efficiency and performance of concrete pipes through fiber reinforcement", Constr. Build. Mater., 45, 36-44. https://doi.org/10.1016/j.conbuildmat.2013.03.084
- Peyvandi, A., Soroushian, P. and Jahangirnejad, S. (2014), "Structural design methodologies for concrete pipes with steel and synthetic fiber reinforcement", ACI Struct. J.
- Rostami, V., Shao, Y. and Boyd, A.J. (2011), "Durability of concrete pipes subjected to combined steam and carbonation curing", Constr. Build. Mater., 25, 3345-3355. https://doi.org/10.1016/j.conbuildmat.2011.03.025
- Silva, J.L. (2011). "Analysis of circular reinforced concrete pipes for the diametrical compression test based on the theory of reliability", Ph.D. Dissertation, University of Sao Paulo, Sao Carlos, Brazil.
- Yang, Y., Polak, M.A. and Cascante, G. (2010), "Nondestructive evaluation of the depth of surface-breaking cracks in concrete pipes", Tunn. Undergr. Space Technol., 25, 736-744. https://doi.org/10.1016/j.tust.2009.12.005
Cited by
- Based on experiment and simulation to evaluate the quality of large diameter concrete drain-pipe by jacking method vol.28, pp.3, 2021, https://doi.org/10.12989/cac.2021.28.3.321