Acknowledgement
Supported by : STARmed Co.
References
- Bruix J, Sherman M; American Association for the Study of Liver Diseases. Management of hepatocellular carcinoma: an update. Hepatology 2011;53:1020-1022 https://doi.org/10.1002/hep.24199
- European Association for the Study of the Liver; European Organisation for Research and Treatment of Cancer. EASL-EORTC clinical practice guidelines: management of hepatocellular carcinoma. J Hepatol 2012;56:908-943 https://doi.org/10.1016/j.jhep.2011.12.001
- Salhab M, Canelo R. An overview of evidence-based management of hepatocellular carcinoma: a meta-analysis. J Cancer Res Ther 2011;7:463-475 https://doi.org/10.4103/0973-1482.92023
- Wu YZ, Li B, Wang T, Wang SJ, Zhou YM. Radiofrequency ablation vs hepatic resection for solitary colorectal liver metastasis: a meta-analysis. World J Gastroenterol 2011;17:4143-4148 https://doi.org/10.3748/wjg.v17.i36.4143
- Chen MS, Li JQ, Zheng Y, Guo RP, Liang HH, Zhang YQ, et al. A prospective randomized trial comparing percutaneous local ablative therapy and partial hepatectomy for small hepatocellular carcinoma. Ann Surg 2006;243:321-328 https://doi.org/10.1097/01.sla.0000201480.65519.b8
- Wang JH, Wang CC, Hung CH, Chen CL, Lu SN. Survival comparison between surgical resection and radiofrequency ablation for patients in BCLC very early/early stage hepatocellular carcinoma. J Hepatol 2012;56:412-418 https://doi.org/10.1016/j.jhep.2011.05.020
- Ahmed M, Brace CL, Lee FT Jr, Goldberg SN. Principles of and advances in percutaneous ablation. Radiology 2011;258:351-369 https://doi.org/10.1148/radiol.10081634
- Goldberg SN. Science to practice: which approaches to combination interventional oncologic therapy hold the greatest promise of obtaining maximal clinical benefit? Radiology 2011;261:667-669 https://doi.org/10.1148/radiol.111906
- Laeseke PF, Sampson LA, Haemmerich D, Brace CL, Fine JP, Frey TM, et al. Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: in vivo porcine liver results. Radiology 2006;241:116-124 https://doi.org/10.1148/radiol.2411051271
- Lee JM, Han JK, Kim HC, Kim SH, Kim KW, Joo SM, et al. Multiple-electrode radiofrequency ablation of in vivo porcine liver: comparative studies of consecutive monopolar, switching monopolar versus multipolar modes. Invest Radiol 2007;42:676-683 https://doi.org/10.1097/RLI.0b013e3180661aad
-
Lee ES, Lee JM, Kim KW, Lee IJ, Han JK, Choi BI. Evaluation of the in vivo efficiency and safety of hepatic radiofrequency ablation using a 15-G
$Octopus^{(R)}$ in pig liver. Korean J Radiol 2013;14:194-201 https://doi.org/10.3348/kjr.2013.14.2.194 - Wang X, Hu Y, Ren M, Lu X, Lu G, He S. Efficacy and safety of radiofrequency ablation combined with transcatheter arterial chemoembolization for hepatocellular carcinomas compared with radiofrequency ablation alone: a time-to-event metaanalysis. Korean J Radiol 2016;17:93-102 https://doi.org/10.3348/kjr.2016.17.1.93
- Kim JW, Shin SS, Heo SH, Hong JH, Lim HS, Seon HJ, et al. Ultrasound-guided percutaneous radiofrequency ablation of liver tumors: how we do it safely and completely. Korean J Radiol 2015;16:1226-1239 https://doi.org/10.3348/kjr.2015.16.6.1226
- Hori T, Nagata K, Hasuike S, Onaga M, Motoda M, Moriuchi A, et al. Risk factors for the local recurrence of hepatocellular carcinoma after a single session of percutaneous radiofrequency ablation. J Gastroenterol 2003;38:977-981 https://doi.org/10.1007/s00535-003-1181-0
- Stigliano R, Marelli L, Yu D, Davies N, Patch D, Burroughs AK. Seeding following percutaneous diagnostic and therapeutic approaches for hepatocellular carcinoma. What is the risk and the outcome? Seeding risk for percutaneous approach of HCC. Cancer Treat Rev 2007;33:437-447 https://doi.org/10.1016/j.ctrv.2007.04.001
- Imamura J, Tateishi R, Shiina S, Goto E, Sato T, Ohki T, et al. Neoplastic seeding after radiofrequency ablation for hepatocellular carcinoma. Am J Gastroenterol 2008;103:3057-3062 https://doi.org/10.1111/j.1572-0241.2008.02153.x
- Snoeren N, Jansen MC, Rijken AM, van Hillegersberg R, Slooter G, Klaase J, et al. Assessment of viable tumour tissue attached to needle applicators after local ablation of liver tumours. Dig Surg 2009;26:56-62 https://doi.org/10.1159/000194946
- Park SI, Kim IJ, Lee SJ, Shin MW, Shin WS, Chung YE, et al. Angled cool-tip electrode for radiofrequency ablation of small superficial subcapsular tumors in the liver: a feasibility study. Korean J Radiol 2016;17:742-749 https://doi.org/10.3348/kjr.2016.17.5.742
- Seror O, N'Kontchou G, Van Nhieu JT, Rabahi Y, Nahon P, Laurent A, et al. Histopathologic comparison of monopolar versus no-touch multipolar radiofrequency ablation to treat hepatocellular carcinoma within Milan criteria. J Vasc Interv Radiol 2014;25:599-607 https://doi.org/10.1016/j.jvir.2013.11.025
-
Wu LW, Chen CY, Liu CJ, Chen MY, Liu PC, Liu PF, et al. Multipolar radiofrequency ablation with non-touch technique for hepatocellular carcinoma
${\leq}$ 3 cm: a preliminary report. Adv Dig Med 2014;1:80-85 https://doi.org/10.1016/j.aidm.2013.09.004 - Hocquelet A, Aube C, Rode A, Cartier V, Sutter O, Manichon AF, et al. Comparison of no-touch multi-bipolar vs. monopolar radiofrequency ablation for small HCC. J Hepatol 2017;66:67-74 https://doi.org/10.1016/j.jhep.2016.07.010
- Seror O, N'Kontchou G, Nault JC, Rabahi Y, Nahon P, Ganne-Carrie N, et al. Hepatocellular carcinoma within Milan criteria: no-touch multibipolar radiofrequency ablation for treatment-long-term results. Radiology 2016;280:611-621 https://doi.org/10.1148/radiol.2016150743
- Lee JM, Kim SH, Han JK, Sohn KL, Choi BI. Ex vivo experiment of saline-enhanced hepatic bipolar radiofrequency ablation with a perfused needle electrode: comparison with conventional monopolar and simultaneous monopolar modes. Cardiovasc Intervent Radiol 2005;28:338-345 https://doi.org/10.1007/s00270-004-0177-3
- Osaki Y, Ikeda K, Izumi N, Yamashita S, Kumada H, Hatta S, et al. Clinical effectiveness of bipolar radiofrequency ablation for small liver cancers. J Gastroenterol 2013;48:874-883 https://doi.org/10.1007/s00535-012-0685-x
- Yoon JH, Lee JM, Woo S, Hwang EJ, Hwang I, Choi W, et al. Switching bipolar hepatic radiofrequency ablation using internally cooled wet electrodes: comparison with consecutive monopolar and switching monopolar modes. Br J Radiol 2015;88:20140468 https://doi.org/10.1259/bjr.20140468
- Lee FT Jr, Haemmerich D, Wright AS, Mahvi DM, Sampson LA, Webster JG. Multiple probe radiofrequency ablation: pilot study in an animal model. J Vasc Interv Radiol 2003;14:1437-1442 https://doi.org/10.1097/01.RVI.0000096771.74047.C8
- Yoon JH, Lee JM, Han JK, Choi BI. Dual switching monopolar radiofrequency ablation using a separable clustered electrode: comparison with consecutive and switching monopolar modes in ex vivo bovine livers. Korean J Radiol 2013;14:403-411 https://doi.org/10.3348/kjr.2013.14.3.403
- Kim YS, Rhim H, Cho OK, Koh BH, Kim Y. Intrahepatic recurrence after percutaneous radiofrequency ablation of hepatocellular carcinoma: analysis of the pattern and risk factors. Eur J Radiol 2006;59:432-441 https://doi.org/10.1016/j.ejrad.2006.03.007
- Nakazawa T, Kokubu S, Shibuya A, Ono K, Watanabe M, Hidaka H, et al. Radiofrequency ablation of hepatocellular carcinoma: correlation between local tumor progression after ablation and ablative margin. AJR Am J Roentgenol 2007;188:480-488 https://doi.org/10.2214/AJR.05.2079
- Kim YS, Lee WJ, Rhim H, Lim HK, Choi D, Lee JY. The minimal ablative margin of radiofrequency ablation of hepatocellular carcinoma (> 2 and < 5 cm) needed to prevent local tumor progression: 3D quantitative assessment using CT image fusion. AJR Am J Roentgenol 2010;195:758-765 https://doi.org/10.2214/AJR.09.2954
- Ahmed M, Solbiati L, Brace CL, Breen DJ, Callstrom MR, Charboneau JW, et al. Image-guided tumor ablation: standardization of terminology and reporting criteria--a 10-year update. Radiology 2014;273:241-260 https://doi.org/10.1148/radiol.14132958
- Tulikangas PK, Smith T, Falcone T, Boparai N, Walters MD. Gross and histologic characteristics of laparoscopic injuries with four different energy sources. Fertil Steril 2001;75:806-810 https://doi.org/10.1016/S0015-0282(00)01785-4
- Martin KE, Moore CM, Tucker R, Fuchshuber P, Robinson T. Quantifying inadvertent thermal bowel injury from the monopolar instrument. Surg Endosc 2016;30:4776-4784 https://doi.org/10.1007/s00464-016-4807-z
- Pillai K, Akhter J, Chua TC, Shehata M, Alzahrani N, Al-Alem I, et al. Heat sink effect on tumor ablation characteristics as observed in monopolar radiofrequency, bipolar radiofrequency, and microwave, using ex vivo calf liver model. Medicine (Baltimore) 2015;94:e580 https://doi.org/10.1097/MD.0000000000000580
- Llovet JM, Vilana R, Bru C, Bianchi L, Salmeron JM, Boix L, et al. Increased risk of tumor seeding after percutaneous radiofrequency ablation for single hepatocellular carcinoma. Hepatology 2001;33:1124-1129 https://doi.org/10.1053/jhep.2001.24233
- Cabibbo G, Craxi A. Needle track seeding following percutaneous procedures for hepatocellular carcinoma. World J Hepatol 2009;1:62-66 https://doi.org/10.4254/wjh.v1.i1.62
- Kawamura Y, Ikeda K, Fukushima T, Hara T, Hosaka T, Kobayashi M, et al. Potential of a no-touch pincer ablation procedure for small hepatocellular carcinoma that uses a multipolar radiofrequency ablation system: an experimental animal study. Hepatol Res 2014;44:1234-1240 https://doi.org/10.1111/hepr.12240
Cited by
- RE: Should We Use a Monopolar or Bipolar Mode for Performing No-Touch Radiofrequency Ablation of Liver Tumors? Clinical Practice Might have Already Resolved the Matter Once and for All vol.18, pp.4, 2017, https://doi.org/10.3348/kjr.2017.18.4.749
- No-touch radiofrequency ablation using multiple electrodes: An in vivo comparison study of switching monopolar versus switching bipolar modes in porcine livers vol.12, pp.4, 2017, https://doi.org/10.1371/journal.pone.0176350
- In Vitro and In Vivo Experimental Studies of A Novel MR-Guided Method for Bipolar Radiofrequency Liver Ablation vol.6, pp.None, 2017, https://doi.org/10.1109/access.2017.2788858
- Recent Advances in the Image-Guided Tumor Ablation of Liver Malignancies: Radiofrequency Ablation with Multiple Electrodes, Real-Time Multimodality Fusion Imaging, and New Energy Sources vol.19, pp.4, 2018, https://doi.org/10.3348/kjr.2018.19.4.545
- No-Touch Radiofrequency Ablation of VX2 Hepatic Tumors In Vivo in Rabbits: A Proof of Concept Study vol.19, pp.6, 2018, https://doi.org/10.3348/kjr.2018.19.6.1099
- Could Monopolar Mode be a Suitable Strategy of Energy Deposition for Performing No-Touch Radiofrequency Ablation of Liver Tumor ≤ 5 cm? vol.41, pp.10, 2017, https://doi.org/10.1007/s00270-018-1946-8
- A Glimpse on Trends and Characteristics of Recent Articles Published in the Korean Journal of Radiology vol.20, pp.12, 2019, https://doi.org/10.3348/kjr.2019.0928
- Characteristics of Recent Articles Published in the Korean Journal of Radiology Based on the Citation Frequency vol.21, pp.12, 2020, https://doi.org/10.3348/kjr.2020.1322
- Switching Monopolar No-Touch Radiofrequency Ablation Using Octopus Electrodes for Small Hepatocellular Carcinoma: A Randomized Clinical Trial vol.10, pp.1, 2021, https://doi.org/10.1159/000512338
- Comparison of ablation performance between dual internally cooled wet tip and conventional dual internally cooled tip radiofrequency electrodes: an experimental study in ex vivo bovine liver vol.38, pp.1, 2017, https://doi.org/10.1080/02656736.2021.1876255
- Challenges Facing Percutaneous Ablation in the Treatment of Hepatocellular Carcinoma: Extension of Ablation Criteria vol.8, pp.None, 2017, https://doi.org/10.2147/jhc.s298709
- New Biparietal Bipolar Catheter Prototype for Hybrid Atrial Fibrillation Ablation vol.16, pp.2, 2017, https://doi.org/10.1177/1556984520981025
- Biparietal bidirectional bipolar radiofrequency in hybrid cardiac ablation: an in vitro evaluation vol.33, pp.1, 2017, https://doi.org/10.1093/icvts/ivab047
- Mathematical modeling of a new way of renal artery denervation vol.2090, pp.1, 2017, https://doi.org/10.1088/1742-6596/2090/1/012005