References
- Bahmani, P., van de Lindt, J. and Dao, T.N. (2014), "Displacement-based design of buildings with torsion: Theory and verification", J. Struct. Eng., ASCE, 140(6), 267-280.
- Carlson, J. and Spencer, B. (1996), "Magnetorheological fluid dampers for semi-active control", Proceedings of the 3rd International Conference on Motion and Vibration Control, 3, 35-40.
- Ghasemi, M.R. and Barghi, E. (2012), "Estimation of inverse dynamic behavior of MR dampers using artificial and fuzzybased neural networks", Int. J. Optimiz. Civ. Eng., 2(3), 357-368.
- Kamatchi P., Ramana G.V., Nagpal A.K., Iyer N.R. and Bhat J.A. (2015), "Dynamic to static eccentricity ratio for site-specific earthquakes", Earthq. Struct., 9(2), 391-413. https://doi.org/10.12989/eas.2015.9.2.391
- Kevadkar, M.D. and Kodag, P.B. (2013), "Lateral load analysis of R.C.C. building", Int. J. Modern Eng. Res., 3(3), 1428-1434.
- Mousaad, A. (2013), "Vibration control of buildings using magnetorheological damper: A new control algorithm", J. Eng., Hindawi Publishing Corporation, doi: 10.1155/2013/596078.
- Nigdeli, S.M. (2014), "Effect of feedback on PID controlled active structures under earthquake excitations", Earthq. Struct., 6(2), 1171-1186.
- Serror, M.H., Diab, R.A. and Mourad, S.A. (2014), "Seismic force reduction factor for steel moment resisting frames with supplemental viscous dampers", Earthq. Struct., 7(6), 1171-1186. https://doi.org/10.12989/eas.2014.7.6.1171
- Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1996), "Seismic response reduction using magnetorheological dampers", Proceedings of the IFAC World Congress, San Francisco, CA.
- Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1998), "An experimental study of MR dampers for seismic protection", Smart Mater. Struct., 7(5), 693-703. https://doi.org/10.1088/0964-1726/7/5/012
- Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1996), "Experimental verification of semi-active control strategies using acceleration feedback", Proceedings of 3rd International Conference on Motion and Vibration Control, 3, 291-296.
- Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1996), "Modeling and control of magnetorheological dampers for seismic response reduction", Smart Mater. Struct., 5(5), 565-575. https://doi.org/10.1088/0964-1726/5/5/006
- Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1997), "Phenomenological model for magnetorheological dampers", J. Eng. Mech., ASCE, 123(3), 230-238. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:3(230)
- Spencer, B., Yang, G., Carlson, J. and Sain, M. (1998), "Smart dampers for seismic protection of structures: a full-scale study", Proceeding of the 2nd World Conference on Structural Control, Kyoto, Japan.
- Spencer, B., Yang, G., Carlson, J. and Sain, M. (2002), "Largescale MR fluid dampers: modeling and dynamic performance considerations", Eng. Struct., 24(3), 309-323. https://doi.org/10.1016/S0141-0296(01)00097-9
- Stathi, C.G., Bakas, N.P., Lagaros, N.D. and Papadrakakis, M. (2015), "Ratio of Torsion (ROT): An index for assessing the global induced torsion in plan irregular buildings", Earthq. Struct., 9(1), 145-171. https://doi.org/10.12989/eas.2015.9.1.145
- Tsang, H.H., Su, K. and Chandler, A. (2006), "Simplified inverse dynamics models for MR fluid dampers", Eng. Struct., 28(3), 327-341. https://doi.org/10.1016/j.engstruct.2005.06.013
- Yang, G. (2001), "Large-scale magnetorheological fluid damper for vibration mitigation: Modeling, testing and control", Ph.D. dissertation, University of Notre Dame.
- Zadeh, L.A. (1965), "Fuzzy sets", Inform. Control., 8(3), 338-353. https://doi.org/10.1016/S0019-9958(65)90241-X