초록

In recent emerging industry, Display field becomes bigger and bigger, and also semiconductor technology becomes high density integration. In Flat Panel Display, there is an issue that electrostatic phenomenon results in fine dust adsorption as electrostatic capacity increases due to bigger size. Destruction of high integrated circuit and pattern deterioration occur in semiconductor and this causes the problem of weakening of thermal resistance. In order to solve this sort of electrostatic failure in this process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. X-ray Generating efficiency has an effect on soft X-ray Ionizer affects neutralizing performance. There exist variable factors such as type of anode, thickness, tube voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was measured according to target material thickness using MCNPX under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W), Gold(Au), Silver(Ag). At the result, Gold(Au) shows optimum efficiency. In Tube voltage 5 keV, optimal target thickness is $0.05{\mu}m$ and Largest energy of Light flux appears $2.22{\times}10^8$ x-ray flux. In Tube voltage 10 keV, optimal target Thickness is $0.18{\mu}m$ and Largest energy of Light flux appears $1.97{\times}10^9$ x-ray flux. In Tube voltage 15 keV, optimal target Thickness is $0.29{\mu}m$ and Largest energy of Light flux appears $4.59{\times}10^9$ x-ray flux.

키워드

참고문헌

  1. S. M. Kim and D. H. Lee, "Study of Application of the Static Electricity Removing Devices at TFT-LCD and AMOLED TFT Process", Master's Thesis of Pukyong National University, pp. 44-58, 2015.
  2. Adachi T, Kawasaki M and Nakabayashi H, "The Behavior of Dust Particle in Electrostatic Precipitators", Journal of the Institute of Electrostatics Japan, Vol. 4, No. 3, pp. 152-159, 1980.
  3. S. Soichiro, I. Hitoshi and T. Yoshida, "Contamination-Free Ionizer for Super Clean Rooms", Proc. 3rd Int. Aerosol Conference Japan, pp. 817-820, 1990.
  4. S. Y. Kwon and D. H. Lee, "A Study on Characteristics of Electrostatic Eliminator used Corona Discharge and Soft X-ray", Doctor's Thesis of Pukyong National University, pp. 21-88, 2010.
  5. H. S. Hong and K. S. Joo, "A Study on Comparison of Resolution according to Filter Material and Calculation of the Radiation Dose of X-ray Generator using MCNPX Code", Master's Thesis of Myongji University, pp. 2-16, 2015.
  6. P. J Duke and A.G. Michette, "Modern Microscopies, Techniques and Applications", Plenum Press New York, pp. 41-45, 1990.