DOI QR코드

DOI QR Code

Influence of resin-nanoceramic CAD/CAM block shade and thickness on the microhardness of dual-cured resin cement

레진-나노세라믹 CAD/CAM블록의 색조와 두께가 이원중합 레진시멘트의 미세경도에 미치는 영향

  • Choi, Ga-Young (Department of conservative dentistry, School of Dentistry, Pusan National University) ;
  • Park, Jeong-Kil (Department of conservative dentistry, School of Dentistry, Pusan National University) ;
  • Jin, Myoung-Uk (Department of conservative dentistry, School of Dentistry, KyungBok National University) ;
  • Kwon, Yong Hoon (Department of Dental Material, School of Dentistry, Pusan National University) ;
  • Son, Sung-Ae (Department of conservative dentistry, School of Dentistry, Pusan National University)
  • 최가영 (부산대학교 치의학전문대학원 치과보존학교실) ;
  • 박정길 (부산대학교 치의학전문대학원 치과보존학교실) ;
  • 진명욱 (경북대학교 치의학전문대학원 치과보존학교실) ;
  • 권용훈 (부산대학교 치의학전문대학원 치과재료학교실) ;
  • 손성애 (부산대학교 치의학전문대학원 치과보존학교실)
  • Received : 2017.06.05
  • Accepted : 2017.06.22
  • Published : 2017.06.30

Abstract

The purpose of this study was to examine the effect of shade and thickness of resin-nanoceramic CAD-CAM block (RNB) on the microhardness of dual-cured resin cement, as well as to measure the number of photons transmitted through RNBs of different thicknesses and colors. One dual-cured resin cement was used to prepare resin cement specimens. Resin cement specimens were light-cured for 40 seconds through 3 shades (A1, A2, A3 in HT (high translucency) and LT (low translucency) respectively) and four thicknesses (1, 2, 3, 4 mm) of RNB specimens. Vickers microhardness measurements of resin cement specimens were performed using a Vickers hardness tester. The light transmission of RNB specimens was measured using a spectrometer (SpectroPro-500, Acton Research, Acton, MA, U.S.A.), and the translucency parameter was calculated using the CIEL*a*b* system. Data were statistically analyzed by ANOVA and Tukey's test. There was a significant decrease of microhardness of resin cement specimen with an overlay of 4 mm of RNB thickness and A3 shade in comparison to A1 and 1 mm, respectively (p<0.05). The translucency parameter values and light transmission of RNBs tested differed significantly, according to the thicknesses of the specimen (p<0.05). Light transmission is decreased with increase in the thicknesses of RNBs. Shade A1 transmitted more light than darker blocks. A decrease in microhardness of resin cement specimens was observed with increasing thickness and shade (A1 to A3) of RNBs.

본 연구에서는 다양한 두께와 색조를 가진 레진 -나노세라믹 CAD-CAM block(RNB)의 시편을 이용하여 광중합 시 시편을 투과하는 광자의 수와 시편을 통과하는 빛의 양에 영향을 미칠 수 있는 반투명도 지수를 측정하고, 시편 하방의 이원중합 레진시멘트의 미세경도 측정을 통해 그 중합적 특성을 파악하였다. Lava Ultimate (3M/ESPE, St. Paul, MN, USA) 세라믹 시편을 A1, A2, A3색조 (HT (high translucency)와 LT (low translucency))로 각각 1, 2, 3, 4 mm 두께로 제작하였다 (n = 3). Photodiode detector (M1420, EG&G PARC, Princeton, NJ, U.S.A.)를 통해 시편을 통과하는 광자의 수를 측정하였고 spectrophotometer (SpectroPro-500, Acton Research, Acton, MA, U.S.A.)를 이용하여 시편의 반투명도 지수를 측정하였다. Stainless steel mold (6 mm 직경, 1 mm 두께)를 제작하여 이원중합 레진시멘트(Rely X ARC, 3M/ESPE, St. Paul, MN, USA)를 제조사의 지시대로 조작하여 적용 후 Mylar strip를 얹은 뒤 주입된 레진시멘트가 완전히 덮일 수 있도록 각 실험군의 시편을 위치시키고 광조사기로 40초간 광중합 하였다. 이후 24시간 동안 $37^{\circ}C$에 보관 후 미세경도를 측정하였다. 광자의 수는 HT, LT군에서 모두 세라믹 시편의 두께가 증가함에 따라 유의하게 감소하였고, A1 군이 A2군과 A3군에 비해 유의하게 적은 감소를 보였다 (p<0.05). 반투명도 지수는 HT, LT 그룹에서 시편의 두께가 증가함에 따라 유의하게 감소하였고 A1군이 A2군과 A3군에 비해 높은 값을 나타냈다 (p<0.05). HT, LT그룹 각각 두께가 증가함에 따라, 색조가 증가함에 따라 미세경도는 감소하였으며, 1 mm군과 4 mm군, 그리고 A1군과 A3군에서는 통계적으로 유의하게 감소하였다 (p<0.05).

Keywords

Acknowledgement

Supported by : Pusan National University