DOI QR코드

DOI QR Code

Self-control of high rise building L-shape in plan considering soil structure interaction

  • Farghaly, A.A. (Civil and Architecture Structures, Sohag University)
  • 투고 : 2017.03.30
  • 심사 : 2017.05.22
  • 발행 : 2017.09.25

초록

A new technique to mitigate irregular buildings with soil structure interaction (SSI) effect subjected to critical seismic waves is presented. The L-shape in plan irregular building for various reasons was selected, subjected to seismic a load which is a big problem for structural design especially without separation gap. The L-shape in plan building with different dimensions was chosen to study, with different rectangularity ratios and various soil kinds, to show the effect of the irregular building on the seismic response. A 3D building subjected to critical earthquake was analyzed by structural analysis program (SAP2000) fixed and with SSI (three types of soils were analyzed, soft, medium and hard soils) to find their effect on top displacement, base shear, and base torsion. The straining actions were appointed and the treatment of the effect of irregular shape under critical earthquake was made by using tuned mass damper (TMD) with different configurations with SSI and without. The study improve the success of using TMDs to mitigate the effect of critical earthquake on irregular building for both cases of study as fixed base and raft foundation (SSI) with different TMDs parameters and configurations. Torsion occurs when the L-shape in plan building subjected to earthquake which may be caused harmful damage. TMDs parameters which give the most effective efficiency in the earthquake duration must be defined, that will mitigate these effects. The parameters of TMDs were studied with structure for different rectangularity ratios and soil types, with different TMD configurations. Nonlinear time history analysis is carried out by SAP2000 with El Centro earthquake wave. The numerical results of the parametric study help in understanding the seismic behavior of L-shape in plan building with TMDs mitigation system.

키워드

참고문헌

  1. Aly, A.M. (2014), "Vibration control of high-rise buildings for wind: A robust passive and active tuned mass damper", Smart Struct. Syst., 13(3), 473-500. https://doi.org/10.12989/sss.2014.13.3.473
  2. Aly, A.M. (2015), "Control of wind-induced motion in high-rise buildings with hybrid TM/MR dampers", Wind Struct., 21(5), 565-595. https://doi.org/10.12989/was.2015.21.5.565
  3. Bortoluzzi, D., Casciati, S., Elia, L. and Faravelli, L. (2015), "Design of a TMD solution to mitigate windinduced local vibrations in an existing timber footbridge", Smart Struct. Syst., 16(3), 459-478. https://doi.org/10.12989/sss.2015.16.3.459
  4. Daniel, Y. and Lavan, O. (2015), "Optimality criteria based seismic design of multiple tuned-mass-dampers for the control of 3D irregular buildings", Earthq. Struct., 8(1), 77-100. https://doi.org/10.12989/eas.2015.8.1.077
  5. Den, H. (1956), Mechanical Vibrations, 4th Edition, McGraw Hill, New York, U.S.A.
  6. Farghaly, A.A. and Abdelrahim, H.H.A. (2013), "Contribution of soil-structure interaction to seismic response of buildings", KSCE J. Civil Eng., 17(5), 959-971. https://doi.org/10.1007/s12205-013-0261-9
  7. Farshidianfar, A. and Soheili, S. (2013), "ABC optimization of TMD parameters for tall buildings with soil structure interaction", Interact. Multisc. Mech., 6(4), 339-356. https://doi.org/10.12989/imm.2013.6.4.339
  8. GebrailBekdas, G. and SinanMelihNigdeli, S.M. (2017), "Metaheuristic based optimization of tuned mass dampers under earthquake excitation by considering soil-structure interaction", Soil Dyn. Earthq. Eng., 92, 443-461. https://doi.org/10.1016/j.soildyn.2016.10.019
  9. Gilani, A.S.J.H., Kit, M., Stepehn, M. and Robert, N. (2012), Seismic Retrofit of the Lax Theme Building with Mass Damper: Analysis and Experimentation, 15 WCEE, Lisboa.
  10. Khante, S.N. and Nirwan, B.P. (2013), "Mitigation of response of asymmetric building using passive tuned mass damper", J. Sci. Eng. Res., 4(7), 1721-1727.
  11. Lu, X., Kun, D., Weixing, S. and Dagen, W. (2010), "Tuned mass dampers for human-induced vibration control of the expo culture centre at the World Expo 2010 in Shanghai, China", Struct. Eng. Mech., 43(5), 607-621. https://doi.org/10.12989/sem.2012.43.5.607
  12. Lu, Z., Wang, D., Masri, S.F. and Lu, X. (2016), "An experimental study of vibration control of windexcited high-rise buildings using particle tuned mass dampers", Smart Struct. Syst., 18(1), 93-115. https://doi.org/10.12989/sss.2016.18.1.093
  13. Makihara, K., Hirai, H., Yamamoto, Y. and Fukunaga, H. (2015), "Self-reliant wireless health monitoring based on tuned-mass-damper mechanism", Smart Struct. Syst., 15(6), 1625-1642. https://doi.org/10.12989/sss.2015.15.6.1625
  14. Martin, D., Daniel, A. and Oscar, C. (2015), "Performance of TMDs on nonlinear structures subjected to near-fault earthquakes", Smart Struct. Syst., 16(4), 725-742. https://doi.org/10.12989/sss.2015.16.4.725
  15. Matta, E. (2015), "Seismic effectiveness of tuned mass dampers in a life-cycle cost perspective", Earthq. Struct., 9(1), 73-91. https://doi.org/10.12989/eas.2015.9.1.073
  16. Nigdeli, S.M. and Bekdas, G. (2013), "Optimum tuned mass damper design for preventing brittle fracture of RC buildings", Smart Struct. Syst., 12(2), 137-155. https://doi.org/10.12989/sss.2013.12.2.137
  17. Nigdeli, S.M. and Bekdaş, G. (2014), "Optimum tuned mass damper approaches for adjacent structures", Eartq. Struct., 7(6), 1071-1091. https://doi.org/10.12989/eas.2014.7.6.1071
  18. Quaranta, G., Mollaioli, F. and Monti, G. (2016), "Effectiveness of design procedures for linear TMD installed on inelastic structures under pulse-like ground motion", Earthq. Struct., 10(1), 239-260. https://doi.org/10.12989/eas.2016.10.1.239
  19. Rezaee, M. and Mousaad, A.A. (2016), "Vibration control in wind turbines for performance enhancement: A comparative study", Wind Struct., 22(1), 107-131. https://doi.org/10.12989/was.2016.22.1.107
  20. Sadek, F., Mohraz, B., Taylor, A.W. and Chung, R.M. (1997), "A method of estimating the parameters of tuned mass damper for seismic applications", Earthq. Eng. Struct. Dyn., 26, 617-635. https://doi.org/10.1002/(SICI)1096-9845(199706)26:6<617::AID-EQE664>3.0.CO;2-Z
  21. Sadhu, A., Hazra, B. and Narasimhan, S. (2014), "Ambient modal identification of structures equipped with tuned mass dampers using parallel factor blind source separation", Smart Struct. Syst., 13(2), 257-280. https://doi.org/10.12989/sss.2014.13.2.257
  22. Salvi, J. and Rizzi, E. (2016), "Closed-form optimum tuning formulas for passive tuned mass dampers under benchmark excitations", Smart Struct. Syst., 17(2), 231-256. https://doi.org/10.12989/sss.2016.17.2.231
  23. SAP2000: Advanced 10.0.5 (2006), Static and Dynamic Finite Element Analysis of Structures, Comput. Struct. Inc., Berkeley, California, U.S.A.
  24. Sun, C., Nagarajaiah, S. and Dick, A.J. (2014), "Family of smart tuned mass dampers with variable frequency under harmonic excitations and ground motions: Closed-form evaluation", Smart Struct. Syst., 13(2), 319-341. https://doi.org/10.12989/sss.2014.13.2.319
  25. Wang, J.F. and Lin, C.C. (2015), "Extracting parameters of TMD and primary structure from the combined system responses", Smart Struct. Syst., 16(5), 937-960. https://doi.org/10.12989/sss.2015.16.5.937

피인용 문헌

  1. TMD effectiveness for steel high-rise building subjected to wind or earthquake including soil-structure interaction vol.30, pp.4, 2017, https://doi.org/10.12989/was.2020.30.4.423