DOI QR코드

DOI QR Code

Multiple wall dampers for multi-mode vibration control of building structures under earthquake excitation

  • 투고 : 2016.09.19
  • 심사 : 2017.06.08
  • 발행 : 2017.08.25

초록

One of the main concerns of civil engineering researchers is developing or modifying an energy dissipation system that can effectively control structural vibrations, and keep the structural response within tolerable limits during unpredictable events like earthquakes, wind and any kind of thrust load. This article proposes a new type of mass damper system for controlling wideband earthquake vibrations, called Multiple Wall Dampers (MWD). The basic principle of the Tuned Mass Damper (TMD) was used to design the proposed wall damper system. This passive energy dissipation system does not require additional mass for the damping system because the boundary wall mass of the building was used as a damper mass. The multi-mode approach was applied to determine the location and design parameters of the dampers. The dampers were installed based on the maximum amplitude of modes. To optimize the damper parameters, the multi-objective optimization Response Surface Methodology was used, with frequency response and maximum displacement as the objective functions. The obtained structural responses under different earthquake forces demonstrated that the MWD is one of the most capable tools for reducing the responses of multi-storied buildings, and this system can be practically used for new and existing building structures.

키워드

과제정보

연구 과제 주관 기관 : National Research Foundation of Korea

참고문헌

  1. Bakre, S.V. and Jangid, R.S. (2007), "Optimum parameters of tuned mass damper for damped main system", Struct. Control Hlth. Monit., 14(3), 448-470. https://doi.org/10.1002/stc.166
  2. Chen, G. and Wu, J. (2003), "Experimental study on multiple tuned mass dampers to reduce seismic responses of a threestorey building structure", Earthq. Eng. Struct. Dyn., 32(5),793-810. https://doi.org/10.1002/eqe.249
  3. Chey, M., Chase, J.G., Mander, J.B. and Carr, A.J. (2015), "Aseismic smart building isolation systems under multi-level earthquake excitations: Part II, energy-dissipation and damage reduction", Front. Struct. Civil Eng., 9(3), 297-306. https://doi.org/10.1007/s11709-015-0308-8
  4. Chey, M., Geoffrey, C.J., Mander, J.B. and Carr, A.J. (2010), "Semi-active tuned mass damper building systems: Application", Earthq. Eng. Struct. Dyn., 39(1),69-89. https://doi.org/10.1002/eqe.933
  5. Chey, M., Geoffrey, C.J., Mander, J.B. and Carr, A.J. (2013), "Innovative seismic retrofitting strategy of added stories isolation system", Front. Arch. Civil Eng. China, 7(1), 13-23.
  6. Domizio, M., Ambrosini, D. and Curadelli, O. (2015), "Performance of TMDs on nonlinear structures subjected to near-fault earthquakes", Smart Struct. Syst., 16(4), 725-742. https://doi.org/10.12989/sss.2015.16.4.725
  7. Igusa, T. and Xu, K. (1994), "Vibration control using multiple tuned mass dampers", J. Sound Vib., 175(4), 491-503. https://doi.org/10.1006/jsvi.1994.1341
  8. Izanami, K. and Seton, K. (1984), "Optimum design of dual tuned mass dampers and their effectiveness", Japan Soc. Mech. Eng., 50(1), 44-52.
  9. Lee, T.Z.E., Krongchai, C., Lu, N.A.L.M.I., Kittiwachana, S. and Sim, S.F. (2015), "Application of central composite design for optimization of the removal of humic substances using coconut copra", Int. J. Indus. Chem., 6(3), 185-191. https://doi.org/10.1007/s40090-015-0041-0
  10. Li, C. and Liu, Y. (2002), "Further Characteristics for Multiple Tuned Mass Dampers", J. Struct. Eng., 128(10), 1362-1365. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:10(1362)
  11. Lin, C.C., Wang, J.F., Lien, C.H., Chiang, H.W. and Lin, C.S. (2010), "Optimum design and experimental study of multiple tuned mass dampers with limited stroke", Earthq. Eng. Struct. Dyn., 39(14), 1631-1651. https://doi.org/10.1002/eqe.1008
  12. Luigi, P. and Massimiliano, D.I. (2008), "Robust design of a single tuned mass damper for controlling torsional response of asymmetric-plan systems", J. Earthq. Eng., 13(1), 108-128. https://doi.org/10.1080/13632460802347364
  13. Mohebbi, M., Rasouli, H. and Moradpour, S. (2015), "Assessment of the design criteria effect on performance of multiple tuned mass dampers", Adv. Struct. Eng., 18(8), 1141. https://doi.org/10.1260/1369-4332.18.8.1141
  14. Moon, K.S. (2010), "Vertically distributed multiple tuned mass dampers in tall buildings: performance analysis and preliminary design", Struct. Des. Tall Spec. Build., 19(3), 347-366. https://doi.org/10.1002/tal.499
  15. Nguyen, T., Saidi, I., Gad, E., Wilson, J. and Haritos, N. (2012), "Performance of distributed multiple viscoelastic tuned mass dampers for floor vibration applications", Adv. Struct. Eng., 15(3), 547-562. https://doi.org/10.1260/1369-4332.15.3.547
  16. Rajmohan, T. and Palanikumar, K. (2013), "Application of the central composite design in optimization of machining parameters in drilling hybrid metal matrix composites", Measur., 46(4), 1470-1481. https://doi.org/10.1016/j.measurement.2012.11.034
  17. Tuscan, S.S. and Uluca, O. (2003), "Reduction of earthquake response of plane frame buildings by viscoelastic damper", Eng. Struct., 25(14), 1755-1761. https://doi.org/10.1016/j.engstruct.2003.07.001
  18. Wang, A.P. and Lin, Y.H. (2007), "Vibration control of a tall building subjected to earthquake excitation)", J. Sound Vib., 299(4-5), 757-773. https://doi.org/10.1016/j.jsv.2006.07.016
  19. Werkle, H., Butz, C. and Tatar, R. (2013), "Effectiveness of "Detuned" TMD's for beam-kike footbridges", Adv. Struct. Eng., 16(1), 21-31. https://doi.org/10.1260/1369-4332.16.1.21
  20. Xiang, P. and Nishitani, A. (2014), "Seismic vibration control of building structures with multiple tuned mass damper floors integrated", Earthq. Eng. Struct. Dyn., 43(6), 909-925. https://doi.org/10.1002/eqe.2379
  21. Yuxin, L. and Zhitao, L. (2014), "Seismic performance and storeybased stability of suspended buildings", Adv. Struct. Eng., 17(10), 1531. https://doi.org/10.1260/1369-4332.17.10.1531
  22. Zhang, C. (2014), "Control force characteristics of different control strategies for the wind-excited 76-story benchmark building structure", Adv. Struct. Eng., 17(4), 543-560. https://doi.org/10.1260/1369-4332.17.4.543