Acknowledgement
Supported by : National Research Foundation of Korea
References
- Bakre, S.V. and Jangid, R.S. (2007), "Optimum parameters of tuned mass damper for damped main system", Struct. Control Hlth. Monit., 14(3), 448-470. https://doi.org/10.1002/stc.166
- Chen, G. and Wu, J. (2003), "Experimental study on multiple tuned mass dampers to reduce seismic responses of a threestorey building structure", Earthq. Eng. Struct. Dyn., 32(5),793-810. https://doi.org/10.1002/eqe.249
- Chey, M., Chase, J.G., Mander, J.B. and Carr, A.J. (2015), "Aseismic smart building isolation systems under multi-level earthquake excitations: Part II, energy-dissipation and damage reduction", Front. Struct. Civil Eng., 9(3), 297-306. https://doi.org/10.1007/s11709-015-0308-8
- Chey, M., Geoffrey, C.J., Mander, J.B. and Carr, A.J. (2010), "Semi-active tuned mass damper building systems: Application", Earthq. Eng. Struct. Dyn., 39(1),69-89. https://doi.org/10.1002/eqe.933
- Chey, M., Geoffrey, C.J., Mander, J.B. and Carr, A.J. (2013), "Innovative seismic retrofitting strategy of added stories isolation system", Front. Arch. Civil Eng. China, 7(1), 13-23.
- Domizio, M., Ambrosini, D. and Curadelli, O. (2015), "Performance of TMDs on nonlinear structures subjected to near-fault earthquakes", Smart Struct. Syst., 16(4), 725-742. https://doi.org/10.12989/sss.2015.16.4.725
- Igusa, T. and Xu, K. (1994), "Vibration control using multiple tuned mass dampers", J. Sound Vib., 175(4), 491-503. https://doi.org/10.1006/jsvi.1994.1341
- Izanami, K. and Seton, K. (1984), "Optimum design of dual tuned mass dampers and their effectiveness", Japan Soc. Mech. Eng., 50(1), 44-52.
- Lee, T.Z.E., Krongchai, C., Lu, N.A.L.M.I., Kittiwachana, S. and Sim, S.F. (2015), "Application of central composite design for optimization of the removal of humic substances using coconut copra", Int. J. Indus. Chem., 6(3), 185-191. https://doi.org/10.1007/s40090-015-0041-0
- Li, C. and Liu, Y. (2002), "Further Characteristics for Multiple Tuned Mass Dampers", J. Struct. Eng., 128(10), 1362-1365. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:10(1362)
- Lin, C.C., Wang, J.F., Lien, C.H., Chiang, H.W. and Lin, C.S. (2010), "Optimum design and experimental study of multiple tuned mass dampers with limited stroke", Earthq. Eng. Struct. Dyn., 39(14), 1631-1651. https://doi.org/10.1002/eqe.1008
- Luigi, P. and Massimiliano, D.I. (2008), "Robust design of a single tuned mass damper for controlling torsional response of asymmetric-plan systems", J. Earthq. Eng., 13(1), 108-128. https://doi.org/10.1080/13632460802347364
- Mohebbi, M., Rasouli, H. and Moradpour, S. (2015), "Assessment of the design criteria effect on performance of multiple tuned mass dampers", Adv. Struct. Eng., 18(8), 1141. https://doi.org/10.1260/1369-4332.18.8.1141
- Moon, K.S. (2010), "Vertically distributed multiple tuned mass dampers in tall buildings: performance analysis and preliminary design", Struct. Des. Tall Spec. Build., 19(3), 347-366. https://doi.org/10.1002/tal.499
- Nguyen, T., Saidi, I., Gad, E., Wilson, J. and Haritos, N. (2012), "Performance of distributed multiple viscoelastic tuned mass dampers for floor vibration applications", Adv. Struct. Eng., 15(3), 547-562. https://doi.org/10.1260/1369-4332.15.3.547
- Rajmohan, T. and Palanikumar, K. (2013), "Application of the central composite design in optimization of machining parameters in drilling hybrid metal matrix composites", Measur., 46(4), 1470-1481. https://doi.org/10.1016/j.measurement.2012.11.034
- Tuscan, S.S. and Uluca, O. (2003), "Reduction of earthquake response of plane frame buildings by viscoelastic damper", Eng. Struct., 25(14), 1755-1761. https://doi.org/10.1016/j.engstruct.2003.07.001
- Wang, A.P. and Lin, Y.H. (2007), "Vibration control of a tall building subjected to earthquake excitation)", J. Sound Vib., 299(4-5), 757-773. https://doi.org/10.1016/j.jsv.2006.07.016
- Werkle, H., Butz, C. and Tatar, R. (2013), "Effectiveness of "Detuned" TMD's for beam-kike footbridges", Adv. Struct. Eng., 16(1), 21-31. https://doi.org/10.1260/1369-4332.16.1.21
- Xiang, P. and Nishitani, A. (2014), "Seismic vibration control of building structures with multiple tuned mass damper floors integrated", Earthq. Eng. Struct. Dyn., 43(6), 909-925. https://doi.org/10.1002/eqe.2379
- Yuxin, L. and Zhitao, L. (2014), "Seismic performance and storeybased stability of suspended buildings", Adv. Struct. Eng., 17(10), 1531. https://doi.org/10.1260/1369-4332.17.10.1531
- Zhang, C. (2014), "Control force characteristics of different control strategies for the wind-excited 76-story benchmark building structure", Adv. Struct. Eng., 17(4), 543-560. https://doi.org/10.1260/1369-4332.17.4.543