DOI QR코드

DOI QR Code

Earthquake effects on the energy demand of tall reinforced concrete walls with buckling-restrained brace outriggers

  • Beiraghi, Hamid (Department of Civil Engineering, Mahdishahr Branch, Islamic Azad University)
  • Received : 2016.12.06
  • Accepted : 2017.06.05
  • Published : 2017.08.25

Abstract

Reinforced concrete core-wall structures with buckling-restrained brace outriggers are interesting systems which have the ability to absorb and dissipate energy during strong earthquakes. Outriggers can change the energy demand in a tall building. In this paper, the energy demand was studied by using the nonlinear time history analysis for the mentioned systems. First, the structures were designed according to the prescriptive codes. In the dynamic analysis, three approaches for the core-wall were investigated: single plastic hinge (SPH), three plastic hinge (TPH) and extended plastic hinge (EPH). For SPH approach, only one plastic hinge is allowed at the core-wall base. For TPH approach, three plastic hinges are allowed, one at the base and two others at the upper levels. For EPH approach, the plasticity can extend anywhere in the wall. The kinetic, elastic strain, inelastic and damping energy demand subjected to forward directivity near-fault and ordinary far-fault earthquakes were studied. In SPH approach for all near-fault and far-fault events, on average, more than 65 percent of inelastic energy is absorbed by buckling-restrained braces in outrigger. While in TPH and EPH approaches, outrigger contribution to inelastic energy demand is reduced. The contribution of outrigger to inelastic energy absorption for the TPH and EPH approaches does not differ significantly. The values are approximately 25 and 30 percent, respectively.

Keywords

References

  1. ACI 318-14 (2014), Building code requirements for structural concrete and commentary, ACI Committee 318, Farmington Hills.
  2. AISC (2005), Seismic Provision for structural steel buildings. American Institute of Steel Construction, Chicago.
  3. Applied Technology Council (2010), ATC-72: Modeling and Acceptance Criteria for Seismic Design and Analysis of Tall Buildings, ATC, Redwood City, CA.
  4. Arias, A. (1970), A Measure of Earthquake Intensity, Ed. R.J. Hansen, Seismic Design for Nuclear Power Plants, MIT Press, Cambridge, Massachusetts.
  5. Bobby, S., Spence, S. M., Bernardini, E. and Kareem, A. (2014), "Performance-based topology optimization for wind-excited tall buildings: a framework", Eng. Struct., 74, 242-255. https://doi.org/10.1016/j.engstruct.2014.05.043
  6. Bosco, M. and Marino, E.M. (2013), "Design method and behavior factor for steel frames with buckling restrained braces", Earthq. Eng. Struct. Dyn., 42, 1243-1263. https://doi.org/10.1002/eqe.2269
  7. Beiraghi, H., Kheyroddin, A. and Kafi, M.A. (2015), "Nonlinear fiber element analysis of a reinforced concrete shear wall subjected to earthquake records", Tran. Civil Eng., 39, 409-422.
  8. Beiraghi, H., Kheyroddin, A. and Kafi, M.A. (2016a), "Forward directivity near-fault and far-fault ground motion effects on the behavior of reinforced concrete wall tall buildings with one and more plastic hinges", Struct. Des. Tall Spec. Build., 25(11), 519-539. https://doi.org/10.1002/tal.1270
  9. Beiraghi, H. and Siahpolo, N. (2017), "Seismic assessment of RC core-wall building capable of three plastic hinges with outrigger", Struct. Des. Tall Spec. Build., 26, e1306 https://doi.org/10.1002/tal.1306
  10. Beiraghi, H., Kheyroddin, A. and Kafi, M.A. (2016b), "Energy dissipation of tall core-wall structures with multi-plastic hinges subjected to forward directivity near-fault and far-fault earthquakes", Struct. Des. Tall Spec. Build., 25, 801-820. https://doi.org/10.1002/tal.1284
  11. Beiraghi, H., Kheyroddin, A. and Kafi, M.A. (2016c), "Effect of record scaling on the behavior of reinforced concrete core-wall buildings subjected to near-fault and far-fault earthquakes", Scientia Iranica. Tran. A Civil Eng., 24(3), 884.
  12. Bruneau, M. and Wang, N. (1996), "Some aspects of energy methods for the inelastic seismic response of ductile SDOF structures", Eng. Struct., 18(1), 1-12. https://doi.org/10.1016/0141-0296(95)00099-X
  13. Chopra, A.K. (2001), Dynamics of Structures, Prentice-Hall, New Jersey.
  14. Chen, Y., McFarland, D.M., Wang, Z., Spencer Jr, B.F. and Bergman, L.A. (2010), "Analysis of tall buildings with damped outriggers", J. Struct. Eng., 136(11), 1435-1443. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000247
  15. Calugaru, V. and Panagiotou, M. (2012), "Response of tall cantilever wall buildings to strong pulse type seismic excitation", Earthq. Eng. Struct. Dyn., 41, 1301-1318 https://doi.org/10.1002/eqe.1185
  16. Eskandari, R. and Vafaei, D. (2015), "Effects of near-fault records characteristics on seismic performance of eccentrically braced frames", Struct. Eng. Mech., 56(5), 855-870. https://doi.org/10.12989/sem.2015.56.5.855
  17. Eskandari, R., Vafaei, D., Vafaei, J. and Shemshadian, M.E. (2017), "Nonlinear static and dynamic behavior of reinforced concrete steel-braced frames", Earthq. Struct., 12(2), 191-200. https://doi.org/10.12989/eas.2017.12.2.191
  18. Fajfar, P. (1992), "Equivalent ductility factors, taking into account low-cycle fatigue", Earthq. Eng. Struct. Dyn., 23, 507-21.
  19. Fanaie, N. and Afsar Dizaj, E. (2014), "Response modification factor of the frames braced with reduced yielding segment BRB", Struct. Eng. Mech., 50(1), 1-17. https://doi.org/10.12989/sem.2014.50.1.001
  20. Esmaili, O., Epackachi, S., Mirghaderi, R., Taheri Behbahani, A.A. and Vahdani, S. (2011), "Rehabilitation of a high-rise coupled shear wall system in a 56-storey residential reinforced concrete building (Tehran Tower), based on nonlinear dynamic timehistory analyses", Struct. Des. Tall Spec. Build., 20(8), 1035-1047. https://doi.org/10.1002/tal.580
  21. FEMA P695 (2009), Quantification of Building Seismic Performance Factors (ATC-63 Project), Federal Emergency Management Agency, Washington D.C.
  22. Mander, J.B., Priestley, M.J.N. and Park, R. (1988), "Theoretical Stress-Strain Model for Confined Concrete", ASCE J. Struct. Eng., 114(8), 1804-1826 https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
  23. Ghorbanirenani. I., Tremblay, R., Leger, P. and Leclerc, M. (2012), "Shake table testing of slender rc shear walls subjected to eastern north america seismic ground motions", J. Struct. Eng., 138(12), 1515-1529. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000581
  24. Ghodsi, T., Ruiz, J.F., Massie, C. and Chen, Y. (2010), Pacific earthquake engineering research/seismic safety commission tall building design case study", Struct. Des. Tall Spec. Build., 19(2), 197-256.
  25. Haselton, C.B., Liel, A.B., Deierlein, G.G., Dean, B.S. and Chou, J.H. (2011), "Seismic collapse safety of reinforced concrete buildings: I. assessment of ductile moment frames", J. Struct. Eng., 137(4), 481-491. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000318
  26. Hall, J.F., Heaton, T.H., Halling, M.W. and Wald, D.J. (1995), "Near-source ground motion and its effects on flexible buildings", Earthq. Spectra., 11, 569-605. https://doi.org/10.1193/1.1585828
  27. Housner, G.W. (1956), "Limit design of structures to resist earthquakes", Proceedings of 1st World Conference on Earthquake Engineering, Earthquake Engineering Research Institute, Oakland, Calif, USA.
  28. Iervolino, I. and Cornell, C.A. (2008), "Probability of occurrence of velocity pulses in near-source ground motions", Bull. Seismol. Soc. Am., 98(5), 2262-2277. https://doi.org/10.1785/0120080033
  29. Jones, P. and Zareian, F. (2009), "Seismic response of a 40-storey buckling-restrained braced frame designed for the Los Angeles region", Struct. Des. Tall Spec. Build., 22(3), 291-299. https://doi.org/10.1002/tal.687
  30. Marzban, S., Banazadeh, M. and Azarbakht, A. (2014), "Seismic performance of reinforced concrete shear wall frames considering soil-foundation-structure interaction", Struct. Des. Tall Spec. Build., 23(4), 302-318. https://doi.org/10.1002/tal.1048
  31. Massumi, A. and Monavari, B. (2013), "Energy based procedure to obtain target displacement of reinforced concrete structures", Struct. Eng. Mech., 48(5), 681-695 https://doi.org/10.12989/sem.2013.48.5.681
  32. Kalkan, E. and Kunnath, S.K. (2006), "Effects of fling-step and forward directivity on the seismic response of buildings", Earthq. Spectra., 22(2), 367-390. https://doi.org/10.1193/1.2192560
  33. Khashaee, P., Mohraz, B., Sadek, F., Lew, H.S. and Gross, J.L. (2003), "Distribution of earthquake input energy in structures", Report no. NISTIR 6903, Building and Fire Research Laboratory, National Institute of Standards and Technology, Gaithersburg.
  34. Klemencic, R., Fry, A., Hooper, J.D. and Morgen, B.G. (2007), "Performance based design of ductile concrete core wall buildings-issues to consider before detail analysis", Struct. Des. Tall Spec. Build., 16, 599-614. https://doi.org/10.1002/tal.437
  35. Kuwamura, H. and Galambos, T.V. (1989), "Earthquake load for structural reliability", J. Struct. Eng., ASCE, 115(6), 1446-1462. https://doi.org/10.1061/(ASCE)0733-9445(1989)115:6(1446)
  36. LATBSDC (2011), An Alternative Procedure For Seismic Analysis and Design of Tall Buildings Located in the Los Angeles Region, Los Angeles Tall Buildings Structural Design Council.
  37. Liel, A.B., Haselton, C.B. and Deierlein, G.G. (2011), "Seismic collapse safety of reinforced concrete buildings: II. comparative assessment of non-ductile and ductile moment frames", J. Struct. Eng., 137(4), 492-502. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000275
  38. Luco, N. and Cornell, A. (2007), "Structure-specific scalar intensity measures for near source and ordinary earthquake ground motions", Earthq. Spectra, 23(2), 357-92. https://doi.org/10.1193/1.2723158
  39. Mortezaei, A. and Ronagh, H.R. (2013), "Plastic hinge length of reinforced concrete columns subjected to both far-fault and near-fault ground motions having forward directivity", Struct. Des. Tall Spec. Build., 22(12), 903-926. https://doi.org/10.1002/tal.729
  40. National Institute of Standards and Technology (2012), Seismic Design of Cast-in-Place Concrete Special Structural Walls and Coupling Beams, NEHRP Seismic Design Technical Brief No. 6.
  41. Nguyen, A.H., Chintanapakdee, C. and Hayashikawa, T. (2011), "Assessment of current nonlinear static procedures for seismic evaluation of BRBF buildings", J. Constr. Steel Res., 66(8-9), 1118-1127. https://doi.org/10.1016/j.jcsr.2010.03.001
  42. Orakcal, K. and Wallace, J. (2006), "Flexural modeling of reinforced concrete walls-experimental verification", ACI Struct. J., 103(2), 196-206.
  43. Powell, G. (2007), Detailed Example of a Tall Shear Wall Building using CSI's Perform 3D Nonlinear Dynamic Analysis, Computers and Structures Inc. Berkeley, CA.
  44. Panagiotou, M. and Restrepo, J. (2009), "Dual-plastic hinge design concept for reducing higher-mode effects on high-rise cantilever wall buildings", Earthq. Eng. Struct. Dyn., 38, 1359-1380. https://doi.org/10.1002/eqe.905
  45. PERFORM-3D (2011), Nonlinear Analysis and Performance Assessment for 3D Structures, V.4.0.3, Computers and Structures, Inc., Berkeley, CA.
  46. PERFORM-3D (2006), Nonlinear Analysis and Performance Assessment for 3D Structures, V.4, User Guide, Computers and Structures, Inc., Berkeley, CA.
  47. Priestley, M.J.N. and Grant, D.N. (2005), "Viscous damping in seismic design and analysis", J. Earthq. Eng., 9(SP2), 229-255. https://doi.org/10.1142/S1363246905002365
  48. Paulay, T. and Priestley, M.J.N. (1992), Seismic Design of Reinforced Concrete and Masonry Buildings, Wiley, Hoboken, NJ.
  49. Riddell, R. and Garcia, E.J. (2001), "Hysteretic energy spectrum and damage control", Earthq. Eng. Struct. Dyn., 30, 1791-1816. https://doi.org/10.1002/eqe.93
  50. Rahgozar, R. and Sharifi, Y. (2009), "An approximate analysis of Framed tube, Shear core and Belt truss in high-rise building", Struct. Des. Tall Spec. Build., 18, 607-624. https://doi.org/10.1002/tal.503
  51. Simpson, Gumpertz, & Heger, Inc. (2009), Detailed Design Write up for BRBF building, Simpson, Gumpertz, & Heger, Inc., San Francisco, CA.
  52. Somerville, P. (1997), "The characteristics and quantification of near-fault ground motion", Proceedings of the FHWA/NCEER Workshop on the National Representation of Seismic Ground Motion for New and Existing Highway Facilities, Burlingame, California, May.
  53. Teran-Gilmore, A. (1998), "A parametric approach to performance-based numerical seismic design", Earthq. Spectra, 14(3), 501-520. https://doi.org/10.1193/1.1586012
  54. Uang, C.M. and Bertero, V.V. (1997), "Seismic response of an instrumented 13-story steel frame building damaged in the 1994 Northridge earthquake", Earthq. Spectra, 13(1), 131-148. https://doi.org/10.1193/1.1585935
  55. Uang, C.M. and Bertero, V.V. (1990), "Evaluation of seismic energy in structures", Earthq. Eng. Struct. Dyn., 19(1), 77-90. https://doi.org/10.1002/eqe.4290190108
  56. Vafaei, D. and Eskandari, R. (2015), "Seismic response of mega buckling-restrained braces subjected to fling-step and forwarddirectivity near-fault ground motions", Struct. Des. Tall Spec. Build., 24(9), 672-686. https://doi.org/10.1002/tal.1205
  57. Vafaei, D. and Eskandari, R. (2016), "Seismic performance of steel mega braced frames equipped with shape-memory alloy braces under near-fault earthquakes", Struct. Des. Tall Spec. Build., 25(1), 3-21. https://doi.org/10.1002/tal.1225
  58. Vafaei, D., Shemshadian, M.E. and Zahrai, S.M. (2010), "Seismic behavior of BRB frames under near fault excitations", 9th US National and 10th Canadian Conference on Earthquake Engineering.
  59. Zhou, Y. and Li, H. (2013), "Analysis of a high-rise steel structure with viscous damped outriggers", Struct. Des. Tall Spec. Build., 23(13), 963-979. https://doi.org/10.1002/tal.1098
  60. ETABS, Version 15.1.0. (2015), Computers and Structures, Inc., Berkeley, California, USA.
  61. ASCE/SEI 7-2010 (2010), Minimum design loads for buildings and other structures, American Society of Civil Engineers, Reston, VA.

Cited by

  1. Seismic response of dual structures comprised by Buckling-Restrained Braces (BRB) and RC walls vol.72, pp.4, 2017, https://doi.org/10.12989/sem.2019.72.4.443
  2. Outrigger and Belt-Truss System Design for High-Rise Buildings: A Comprehensive Review Part II-Guideline for Optimum Topology and Size Design vol.2020, pp.None, 2020, https://doi.org/10.1155/2020/2589735
  3. Optimum location of second outrigger in RC core walls subjected to NF earthquakes vol.38, pp.6, 2017, https://doi.org/10.12989/scs.2021.38.6.671
  4. Feasibility study of buckling-restrained braces with PM-35 steel core vol.79, pp.2, 2021, https://doi.org/10.12989/sem.2021.79.2.199
  5. Derivation of yield force coefficient for RC frames considering energy balance and P-delta effects vol.79, pp.4, 2017, https://doi.org/10.12989/sem.2021.79.4.429