References
- ACI 318-14 (2014), Building code requirements for structural concrete and commentary, ACI Committee 318, Farmington Hills.
- AISC (2005), Seismic Provision for structural steel buildings. American Institute of Steel Construction, Chicago.
- Applied Technology Council (2010), ATC-72: Modeling and Acceptance Criteria for Seismic Design and Analysis of Tall Buildings, ATC, Redwood City, CA.
- Arias, A. (1970), A Measure of Earthquake Intensity, Ed. R.J. Hansen, Seismic Design for Nuclear Power Plants, MIT Press, Cambridge, Massachusetts.
- Bobby, S., Spence, S. M., Bernardini, E. and Kareem, A. (2014), "Performance-based topology optimization for wind-excited tall buildings: a framework", Eng. Struct., 74, 242-255. https://doi.org/10.1016/j.engstruct.2014.05.043
- Bosco, M. and Marino, E.M. (2013), "Design method and behavior factor for steel frames with buckling restrained braces", Earthq. Eng. Struct. Dyn., 42, 1243-1263. https://doi.org/10.1002/eqe.2269
- Beiraghi, H., Kheyroddin, A. and Kafi, M.A. (2015), "Nonlinear fiber element analysis of a reinforced concrete shear wall subjected to earthquake records", Tran. Civil Eng., 39, 409-422.
- Beiraghi, H., Kheyroddin, A. and Kafi, M.A. (2016a), "Forward directivity near-fault and far-fault ground motion effects on the behavior of reinforced concrete wall tall buildings with one and more plastic hinges", Struct. Des. Tall Spec. Build., 25(11), 519-539. https://doi.org/10.1002/tal.1270
- Beiraghi, H. and Siahpolo, N. (2017), "Seismic assessment of RC core-wall building capable of three plastic hinges with outrigger", Struct. Des. Tall Spec. Build., 26, e1306 https://doi.org/10.1002/tal.1306
- Beiraghi, H., Kheyroddin, A. and Kafi, M.A. (2016b), "Energy dissipation of tall core-wall structures with multi-plastic hinges subjected to forward directivity near-fault and far-fault earthquakes", Struct. Des. Tall Spec. Build., 25, 801-820. https://doi.org/10.1002/tal.1284
- Beiraghi, H., Kheyroddin, A. and Kafi, M.A. (2016c), "Effect of record scaling on the behavior of reinforced concrete core-wall buildings subjected to near-fault and far-fault earthquakes", Scientia Iranica. Tran. A Civil Eng., 24(3), 884.
- Bruneau, M. and Wang, N. (1996), "Some aspects of energy methods for the inelastic seismic response of ductile SDOF structures", Eng. Struct., 18(1), 1-12. https://doi.org/10.1016/0141-0296(95)00099-X
- Chopra, A.K. (2001), Dynamics of Structures, Prentice-Hall, New Jersey.
- Chen, Y., McFarland, D.M., Wang, Z., Spencer Jr, B.F. and Bergman, L.A. (2010), "Analysis of tall buildings with damped outriggers", J. Struct. Eng., 136(11), 1435-1443. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000247
- Calugaru, V. and Panagiotou, M. (2012), "Response of tall cantilever wall buildings to strong pulse type seismic excitation", Earthq. Eng. Struct. Dyn., 41, 1301-1318 https://doi.org/10.1002/eqe.1185
- Eskandari, R. and Vafaei, D. (2015), "Effects of near-fault records characteristics on seismic performance of eccentrically braced frames", Struct. Eng. Mech., 56(5), 855-870. https://doi.org/10.12989/sem.2015.56.5.855
- Eskandari, R., Vafaei, D., Vafaei, J. and Shemshadian, M.E. (2017), "Nonlinear static and dynamic behavior of reinforced concrete steel-braced frames", Earthq. Struct., 12(2), 191-200. https://doi.org/10.12989/eas.2017.12.2.191
- Fajfar, P. (1992), "Equivalent ductility factors, taking into account low-cycle fatigue", Earthq. Eng. Struct. Dyn., 23, 507-21.
- Fanaie, N. and Afsar Dizaj, E. (2014), "Response modification factor of the frames braced with reduced yielding segment BRB", Struct. Eng. Mech., 50(1), 1-17. https://doi.org/10.12989/sem.2014.50.1.001
- Esmaili, O., Epackachi, S., Mirghaderi, R., Taheri Behbahani, A.A. and Vahdani, S. (2011), "Rehabilitation of a high-rise coupled shear wall system in a 56-storey residential reinforced concrete building (Tehran Tower), based on nonlinear dynamic timehistory analyses", Struct. Des. Tall Spec. Build., 20(8), 1035-1047. https://doi.org/10.1002/tal.580
- FEMA P695 (2009), Quantification of Building Seismic Performance Factors (ATC-63 Project), Federal Emergency Management Agency, Washington D.C.
- Mander, J.B., Priestley, M.J.N. and Park, R. (1988), "Theoretical Stress-Strain Model for Confined Concrete", ASCE J. Struct. Eng., 114(8), 1804-1826 https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
- Ghorbanirenani. I., Tremblay, R., Leger, P. and Leclerc, M. (2012), "Shake table testing of slender rc shear walls subjected to eastern north america seismic ground motions", J. Struct. Eng., 138(12), 1515-1529. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000581
- Ghodsi, T., Ruiz, J.F., Massie, C. and Chen, Y. (2010), Pacific earthquake engineering research/seismic safety commission tall building design case study", Struct. Des. Tall Spec. Build., 19(2), 197-256.
- Haselton, C.B., Liel, A.B., Deierlein, G.G., Dean, B.S. and Chou, J.H. (2011), "Seismic collapse safety of reinforced concrete buildings: I. assessment of ductile moment frames", J. Struct. Eng., 137(4), 481-491. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000318
- Hall, J.F., Heaton, T.H., Halling, M.W. and Wald, D.J. (1995), "Near-source ground motion and its effects on flexible buildings", Earthq. Spectra., 11, 569-605. https://doi.org/10.1193/1.1585828
- Housner, G.W. (1956), "Limit design of structures to resist earthquakes", Proceedings of 1st World Conference on Earthquake Engineering, Earthquake Engineering Research Institute, Oakland, Calif, USA.
- Iervolino, I. and Cornell, C.A. (2008), "Probability of occurrence of velocity pulses in near-source ground motions", Bull. Seismol. Soc. Am., 98(5), 2262-2277. https://doi.org/10.1785/0120080033
- Jones, P. and Zareian, F. (2009), "Seismic response of a 40-storey buckling-restrained braced frame designed for the Los Angeles region", Struct. Des. Tall Spec. Build., 22(3), 291-299. https://doi.org/10.1002/tal.687
- Marzban, S., Banazadeh, M. and Azarbakht, A. (2014), "Seismic performance of reinforced concrete shear wall frames considering soil-foundation-structure interaction", Struct. Des. Tall Spec. Build., 23(4), 302-318. https://doi.org/10.1002/tal.1048
- Massumi, A. and Monavari, B. (2013), "Energy based procedure to obtain target displacement of reinforced concrete structures", Struct. Eng. Mech., 48(5), 681-695 https://doi.org/10.12989/sem.2013.48.5.681
- Kalkan, E. and Kunnath, S.K. (2006), "Effects of fling-step and forward directivity on the seismic response of buildings", Earthq. Spectra., 22(2), 367-390. https://doi.org/10.1193/1.2192560
- Khashaee, P., Mohraz, B., Sadek, F., Lew, H.S. and Gross, J.L. (2003), "Distribution of earthquake input energy in structures", Report no. NISTIR 6903, Building and Fire Research Laboratory, National Institute of Standards and Technology, Gaithersburg.
- Klemencic, R., Fry, A., Hooper, J.D. and Morgen, B.G. (2007), "Performance based design of ductile concrete core wall buildings-issues to consider before detail analysis", Struct. Des. Tall Spec. Build., 16, 599-614. https://doi.org/10.1002/tal.437
- Kuwamura, H. and Galambos, T.V. (1989), "Earthquake load for structural reliability", J. Struct. Eng., ASCE, 115(6), 1446-1462. https://doi.org/10.1061/(ASCE)0733-9445(1989)115:6(1446)
- LATBSDC (2011), An Alternative Procedure For Seismic Analysis and Design of Tall Buildings Located in the Los Angeles Region, Los Angeles Tall Buildings Structural Design Council.
- Liel, A.B., Haselton, C.B. and Deierlein, G.G. (2011), "Seismic collapse safety of reinforced concrete buildings: II. comparative assessment of non-ductile and ductile moment frames", J. Struct. Eng., 137(4), 492-502. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000275
- Luco, N. and Cornell, A. (2007), "Structure-specific scalar intensity measures for near source and ordinary earthquake ground motions", Earthq. Spectra, 23(2), 357-92. https://doi.org/10.1193/1.2723158
- Mortezaei, A. and Ronagh, H.R. (2013), "Plastic hinge length of reinforced concrete columns subjected to both far-fault and near-fault ground motions having forward directivity", Struct. Des. Tall Spec. Build., 22(12), 903-926. https://doi.org/10.1002/tal.729
- National Institute of Standards and Technology (2012), Seismic Design of Cast-in-Place Concrete Special Structural Walls and Coupling Beams, NEHRP Seismic Design Technical Brief No. 6.
- Nguyen, A.H., Chintanapakdee, C. and Hayashikawa, T. (2011), "Assessment of current nonlinear static procedures for seismic evaluation of BRBF buildings", J. Constr. Steel Res., 66(8-9), 1118-1127. https://doi.org/10.1016/j.jcsr.2010.03.001
- Orakcal, K. and Wallace, J. (2006), "Flexural modeling of reinforced concrete walls-experimental verification", ACI Struct. J., 103(2), 196-206.
- Powell, G. (2007), Detailed Example of a Tall Shear Wall Building using CSI's Perform 3D Nonlinear Dynamic Analysis, Computers and Structures Inc. Berkeley, CA.
- Panagiotou, M. and Restrepo, J. (2009), "Dual-plastic hinge design concept for reducing higher-mode effects on high-rise cantilever wall buildings", Earthq. Eng. Struct. Dyn., 38, 1359-1380. https://doi.org/10.1002/eqe.905
- PERFORM-3D (2011), Nonlinear Analysis and Performance Assessment for 3D Structures, V.4.0.3, Computers and Structures, Inc., Berkeley, CA.
- PERFORM-3D (2006), Nonlinear Analysis and Performance Assessment for 3D Structures, V.4, User Guide, Computers and Structures, Inc., Berkeley, CA.
- Priestley, M.J.N. and Grant, D.N. (2005), "Viscous damping in seismic design and analysis", J. Earthq. Eng., 9(SP2), 229-255. https://doi.org/10.1142/S1363246905002365
- Paulay, T. and Priestley, M.J.N. (1992), Seismic Design of Reinforced Concrete and Masonry Buildings, Wiley, Hoboken, NJ.
- Riddell, R. and Garcia, E.J. (2001), "Hysteretic energy spectrum and damage control", Earthq. Eng. Struct. Dyn., 30, 1791-1816. https://doi.org/10.1002/eqe.93
- Rahgozar, R. and Sharifi, Y. (2009), "An approximate analysis of Framed tube, Shear core and Belt truss in high-rise building", Struct. Des. Tall Spec. Build., 18, 607-624. https://doi.org/10.1002/tal.503
- Simpson, Gumpertz, & Heger, Inc. (2009), Detailed Design Write up for BRBF building, Simpson, Gumpertz, & Heger, Inc., San Francisco, CA.
- Somerville, P. (1997), "The characteristics and quantification of near-fault ground motion", Proceedings of the FHWA/NCEER Workshop on the National Representation of Seismic Ground Motion for New and Existing Highway Facilities, Burlingame, California, May.
- Teran-Gilmore, A. (1998), "A parametric approach to performance-based numerical seismic design", Earthq. Spectra, 14(3), 501-520. https://doi.org/10.1193/1.1586012
- Uang, C.M. and Bertero, V.V. (1997), "Seismic response of an instrumented 13-story steel frame building damaged in the 1994 Northridge earthquake", Earthq. Spectra, 13(1), 131-148. https://doi.org/10.1193/1.1585935
- Uang, C.M. and Bertero, V.V. (1990), "Evaluation of seismic energy in structures", Earthq. Eng. Struct. Dyn., 19(1), 77-90. https://doi.org/10.1002/eqe.4290190108
- Vafaei, D. and Eskandari, R. (2015), "Seismic response of mega buckling-restrained braces subjected to fling-step and forwarddirectivity near-fault ground motions", Struct. Des. Tall Spec. Build., 24(9), 672-686. https://doi.org/10.1002/tal.1205
- Vafaei, D. and Eskandari, R. (2016), "Seismic performance of steel mega braced frames equipped with shape-memory alloy braces under near-fault earthquakes", Struct. Des. Tall Spec. Build., 25(1), 3-21. https://doi.org/10.1002/tal.1225
- Vafaei, D., Shemshadian, M.E. and Zahrai, S.M. (2010), "Seismic behavior of BRB frames under near fault excitations", 9th US National and 10th Canadian Conference on Earthquake Engineering.
- Zhou, Y. and Li, H. (2013), "Analysis of a high-rise steel structure with viscous damped outriggers", Struct. Des. Tall Spec. Build., 23(13), 963-979. https://doi.org/10.1002/tal.1098
- ETABS, Version 15.1.0. (2015), Computers and Structures, Inc., Berkeley, California, USA.
- ASCE/SEI 7-2010 (2010), Minimum design loads for buildings and other structures, American Society of Civil Engineers, Reston, VA.
Cited by
- Seismic response of dual structures comprised by Buckling-Restrained Braces (BRB) and RC walls vol.72, pp.4, 2017, https://doi.org/10.12989/sem.2019.72.4.443
- Outrigger and Belt-Truss System Design for High-Rise Buildings: A Comprehensive Review Part II-Guideline for Optimum Topology and Size Design vol.2020, pp.None, 2020, https://doi.org/10.1155/2020/2589735
- Optimum location of second outrigger in RC core walls subjected to NF earthquakes vol.38, pp.6, 2017, https://doi.org/10.12989/scs.2021.38.6.671
- Feasibility study of buckling-restrained braces with PM-35 steel core vol.79, pp.2, 2021, https://doi.org/10.12989/sem.2021.79.2.199
- Derivation of yield force coefficient for RC frames considering energy balance and P-delta effects vol.79, pp.4, 2017, https://doi.org/10.12989/sem.2021.79.4.429