Member Utilization Concept Design for Hollow Circular Section Multi-column Tower Subjected to 10MW Level Wind Turbines

10MW급 풍력발전용 원형강관 멀티기둥타워의 부재유용도 개념설계

  • Kim, Kyungsik (Department of Civil Engineering, Cheongju University) ;
  • Kim, Mi Jin (Department of Civil Engineering, Cheongju University)
  • Received : 2017.02.28
  • Accepted : 2017.03.24
  • Published : 2017.06.27

Abstract

This study presents an example of conceptual design for hollow circular section multi-column tower system subjected to 10MW level wind load by introducing a method based on member utilization that examine both structural stability and economical efficiency. The basic assumptions for the proto type of a multi-column tower that can replace a single-cylinder tower were suggested and structural models were constructed following the assumptions and analyzed for identifying member forces. Based on the calculated member strengths and acting loads, the member utilization of the proposed multi-column tower structures were calculated for axial force, shear, bending and torsion and evaluaed for suitability as a wind tower. Design parameters such as steel tube dimensions, slenderness ratio, and number of floors for braces was proposed in the acceptable range of member utilization for conceptual design of multi-column wind towers.

본 연구에서는 10MW급 풍력하중을 받는 멀티기둥 타워시스템에 원형강관 부재의 구조안전성 및 경제성을 함께 검토하는 방식으로 부재 유용도에 근거한 개념설계의 예를 보였다. 단일 실린더형 타워를 대체할 수 있는 멀티기둥타워 구조의 구성에 관한 기본적인 가정을 정립하였고, 그에 따라 제안된 구조물을 모델링하고 해석하여 부재력을 확인하였다. 산정된 부재강도와 작용하중을 근간으로 제안된 멀티기둥타워의 각 부재별로 축력, 전단, 휨, 비틂에 대한 유용도가 산정되었고, 풍력타워로서의 적합성이 평가하였다. 멀티기둥 풍력타워의 개념설계에 채택될 수 있는 수준의 유용도 범위에서 강관 치수, 세장비 및 수평재 단수 등의 설계 매개변수를 제안하였다.

Keywords

References

  1. 김종민, 황민오, 최병호, 김경식(2013) 10MW급 신형식 강재 풍력타워 최적단면 평가, 2013 학술발표대회, 대한토목학회, pp. 2340-2343. Kim, J., Hwang, M.O., Choi, B.H., and Kim, K. (2013) Concept Design of the New-Type 10MW Steel wind Towers, Proceedings of 39th KSCE Conference, pp.2340-2343.
  2. 안준태, 신동구(2015) 풍력발전 타워용 원형단면 강재 쉘의 극한휨강도, 한국강구조학회논문집, 한국강구조학회, 제27권 제1호, pp.109-118. Ahn, J.T. and Shin, D.K. (2015) Ultimate Flexural Strength of Cylindrical Steel Shell for Wind Tower, Journal of Korean Society of Steel Construction, KSSC, Vol. 27. No. 1, pp. 109-118.
  3. 김종민, 박현용, 김경식(2014) 멀티기둥-강관 풍력타워 연결부 성능평가, 한국산학기술학회논문지, 한국산학기술학회, 제15권, 제3호, pp.1764-1769. Kim, J., Park, H.Y., and Kim, K. (2014) Performance Evaluation of Junctions Between Multi-Tubular and Cylindrical Sections for Steel Wind Tower, Journal of Korea Academia-Industrial Cooperation Society, KAIS, Vol.15, No.3, pp.1764-1769. https://doi.org/10.5762/KAIS.2014.15.3.1764
  4. 김경식, 박현용, 서동혁(2015) 원형단면 멀티기둥 풍력타워 적용 T형 강관조인트 강도 평가, 한국강구조학회논문집, 한국강구조학회, 제27권, 제1호, pp.119-129. Kim, K., Park, H.Y., and Seo, D.H. (2015) Strength evaluation of T-type tubular joints for circular section multicolumn wind towers, Journal of Korean Society of Steel Construction, KSSC, Vol.27. No.1, pp.119-129.
  5. AISC (2011) Steel Construction Manual, 14th Ed, AmericanInstitute of Steel Construction, USA.
  6. CEN (2005) Eurocode 3: Design of steel structures, Part1-8: Design of joints, European Committee for Standardization.
  7. CIDECT (2008) Design Guide for Circular Hollow Section (CHS) Joints Under Predominantly Static Loading, Comite International Pour le Developpement et l'Etude de la Construction Tubulaire, 2nd Ed.
  8. ISO 19902 (2007) Petroleum and Natural Gas Industries - Fixed Steel Offshore Structure, International Standard, Switzerland.
  9. 김경식(2016) 압축과 휨을 동시에 받는 강관 T조인트 극한 강도 상호작용, 한국산학기술학회논문지, 한국산학기술학회, 제17권, 제1호, pp.298-303. Kim, K. (2016) Ultimate Strength Interaction of Steel Tubular T-joint Subjected to Concurrent Action of Compression and Bending, Journal of Korea Academia- Industrial Cooperation Society, KAIS, Vol.16, No.2, pp.1516-1523. https://doi.org/10.5762/KAIS.2016.17.1.298
  10. 김경식, 김미진(2016) 원형단면 멀티기둥 풍력타워 적용 강관 부재의 유용도 평가, 2016 학술발표대회, 한국강구조학회, pp.135-136. Kim, K. and Kim, M.J. (2016) Evaluation of members utilization for circular section multi-column wind towers, 2016 Preceedings of Korean Society of Steel Construction Conference, pp.135-136.
  11. CEN (2005) Eurocode 3: Design of Steel Structures - Part 1-1 : General Rules and Rules for Buildings.
  12. Abaqus Inc. (2008), ABAQUS Standard User's Manual, Version 6.8.-2.
  13. 한나, 박종섭, 강성용, 강영종(2015) 설계하중조건에 따른 해상풍력 강재타워 출입구에 발생되는 응력집중에 대한 해석적 연구, 한국산학기술학회논문지, 한국산학기술학회, 제17권, 제1호, pp.298-303. Reyno, H., Park, J.S., Kang, S.Y., and Kang, K.J. (2015) A Numerical Analysis for Stress Concentration of Openings in Offshore Tubular Steel Tower under Design Loading Condition, Journal of Korea Academia-Industrial Cooperation Society, KAIS, Vol.17, No.1, pp.298-303.

Cited by

  1. 지관 압축을 받는 고강도강 X형 원형강관접합부의 구조적 성능에 대한 실험적 연구 vol.29, pp.4, 2017, https://doi.org/10.7781/kjoss.2017.29.4.291