DOI QR코드

DOI QR Code

Performance Analysis on Combined Horizontal Ground Source Heat Pump with Earth tube using EnergyPlus

EnergyPlus를 이용한 수평형의 지열 히트펌프와 어스튜브를 조합한 시스템의 성능 검토

  • Cho, Sung-Woo (Department of Architecture, Changwon International University)
  • Received : 2017.04.14
  • Accepted : 2017.05.31
  • Published : 2017.06.01

Abstract

This study is performed to performance of the combined system the GSHP (Ground Source Heat Pump) system with the Earth tube system using EnergyPlus program. The Earth tube system using fan is characteristics as supply lower (higher) air temperature than outdoor air temperature in cooling and heating seasons, the GSHP system is characteristics as small indoor air temperature variation range. As the results of Earth tube + GSHP system simulation, GSHP power can be reduced than the GSHP single operation as 17.3% in cooling seasons and 32.5% in heating seasons, the GSHP design capacity can be replaced more small size.

Keywords

References

  1. https://www.me.go.kr/home/
  2. Kim, S. J., Lee, K. U., Kim, T. Y., and Leigh, S. B., 2012, Evaluation of the heating performance of vertical and horizontal GSHP system by simulation, Proceeding of AIK, Vol. 32, No. 2, pp. 265-266.
  3. Ihm, P. C. and Cho, S. W., 2016, Experimental study for horizontal heat pump heating performance analysis, Korea Society of Geothermal Energy Engineers, Vol. 12, No. 2, pp. 7-12.
  4. H. Esen, H. Inalli, and M. Esen, 2007, A techno-economic comparison of ground-co upled and air-coupled heat pump system for space cooling, Building Environment, Vol. 42, pp. 1955-1965. https://doi.org/10.1016/j.buildenv.2006.04.007
  5. Tudor P. Todoran and Mugur C. Balan, 2016, Long term behavior of a geothermal heat pump with oversized horizontal collector, Energy and Buildings, Vol. 133, pp. 799-809. https://doi.org/10.1016/j.enbuild.2016.10.037
  6. Na Zhu, Pingfang Hu, Wei Wang, Jianming Yu, and Fei Lei, 2015, Performance analysis of ground water-source heat pump system with improved control strategies for building retrofit, Renewable energy, Vol. 80, pp. 324-330. https://doi.org/10.1016/j.renene.2015.02.021
  7. Hwang, Y. H. and Cho, S. W. 2016, The Study on Energy Plus Simulation Application Feasibility for Exit Air Temperature Prediction through Horizontal Geothermal Heat Exchanger, SAREK, Vol. 28, No. 4, pp. 131-136.
  8. Rohit, M., Vikas, B., Ghanshyam, D. A., Jyotirmay, M., and Tarun, A., 2013, Transient analysis based determination of derating factor for earth air tunnel heat exchanger in summer, Energy and buildings, Vol. 58, pp. 103-110. https://doi.org/10.1016/j.enbuild.2012.11.001
  9. Cho, S. W. and Ihm, P. C., 2014, A Study on Burial guideline of horizontal geothermal heat exchanger based on exit temperature, SAREK, Vol. 26, No. 12, pp. 553-558.
  10. Ihm, P. C. and Cho, S. W., 2016, Experimental study for horizontal geothermal heat pump heating performance analysis, Korea Society of Geothermal Energy Engineers, Vol. 12, No. 2, pp. 7-12.
  11. Cho, S. W. and Ihm, P. C., 2014, The Study on the prediction of underground temperature in Changwon district, SAREK, Vol. 26, No. 3, pp. 97-102.