References
- R.J. Jaszczak, R.E. Goleman, C.B. Lim, SPECT: single photon emission computed tomography, IEEE Trans. Nucl. Sci. NS-27 (1980) 1137-1153.
- Y.J. Lee, H.J. Ryu, S.W. Lee, S.J. Park, H.J. Kim, Comparison of ultra-high-resolution parallel-hole collimator materials based on the CdTe pixelated semiconductor SPECT system, Nucl. Instrum. Methods Phys. Res. A 713 (2013) 33-39. https://doi.org/10.1016/j.nima.2013.03.014
- M.T. Madsen, Recent advances in SPECT imaging, J. Nucl. Med. 48 (2007) 661-673. https://doi.org/10.2967/jnumed.106.032680
- Y.-J. Lee, S.-J. Park, D.-H. Kim, H.-J. Kim, Optimization of the SPECT systems based on a CdTe pixelated semiconductor detector using novel parallel-hole collimators, J. Instrum. 9 (2014) C05057. https://doi.org/10.1088/1748-0221/9/05/C05057
- C.L. Melcher, J.S. Schweitzer, R.A. Manente, C.A. Peterson, Applications of single crystals in oil well logging, J. Cryst. Growth 109 (1991) 37-42. https://doi.org/10.1016/0022-0248(91)90155-X
- T.E. Peterson, L.R. Furenlid, SPECT detectors: the Anger Camera and beyond, Phys. Med. Biol. 7 (2011) R145-R182.
- M.A.K. Abdelhalim, R.A.-M. Rizk, H.I. Farag, S.M. Reda, Effect of energy window width on planer and SPECT image uniformity, J. King Saud Univ. 21 (2009) 145-150. https://doi.org/10.1016/j.jksus.2009.06.001
- C. Scheiber, CdTe and CdZnTe detectors in nuclear medicine, Nucl. Instrum. Methods Phys. Res. A 448 (2000) 513-524. https://doi.org/10.1016/S0168-9002(00)00282-5
- A. Abe, N. Takahashi, J. Lee, T. Oka, K. Shizukuishi, T. Kikuchi, T. Inoue, M. Jimbo, H. Ryuo, C. Bickel, Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera, Eur. J. Nucl. Med. Mol. Imaging 30 (2003) 805-811. https://doi.org/10.1007/s00259-002-1067-z
- K. Ogawa, M. Muraishi, Feasibility study on an ultra-high-resolution SPECT with CdTe detectors, IEEE Trans. Nucl. Sci. 57 (2010) 17-24. https://doi.org/10.1109/TNS.2009.2034460
- Y. Lee, H.-J. Kim, Performance evaluation of a small CZT pixelated semiconductor gamma camera system with a newly designed stack-up parallel-hole collimator, Nucl. Instrum. Methods Phys. Res. A 794 (2015) 54-61. https://doi.org/10.1016/j.nima.2015.05.007
- T. Onodera, K. Hitomi, T. Shoji, Y. Hiratate, Pixellated thallium bromide detectors for gamma-ray spectroscopy and imaging, Nucl. Instrum. Methods Phys. Res. A 525 (2004) 199-204. https://doi.org/10.1016/j.nima.2004.03.046
- A. Konik, M.T. Madsen, J.J. Sunderland, GATE simulations of small animal SPECT for determination of scatter fraction as a function of object size, IEEE Trans. Nucl. Sci. 59 (2012) 1887-1891. https://doi.org/10.1109/TNS.2012.2205403
- S. Stute, T. Carlier, K. Cristina, C. Noblet, A. Martineau, B. Hutton, L. Barnden, I. Buvat, Monte Carlo simulations of clinical PET and SPECT scans: impact of the input data on the simulated images, Phys. Med. Biol. 56 (2011) 6441-6457. https://doi.org/10.1088/0031-9155/56/19/017
- J.S. Fleming, Evaluation of a technique for simulation of gamma camera images, Phys. Med. Biol. 41 (1996) 1855-1861. https://doi.org/10.1088/0031-9155/41/9/019
- S. Jan, D. Benoit, E. Becheva, T. Carlier, F. Cassol, P. Descourt, T. Frisson, L. Grevillot, L. Guigues, L. Maigne, C. Morel, Y. Perrot, N. Rehfeld, D. Sarrut, D.R. Schaart, S. Stute, U. Pietrzyk, D. Visvikis, N. Zahra, I. Buvat, GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy, Phys. Med. Biol. 56 (2011) 881-901. https://doi.org/10.1088/0031-9155/56/4/001
- P.-H. Jeon, C.-L. Lee, D.-H. Kim, Y.-J. Lee, S.-S. Jeon, H.-J. Kim, Dose reduction and image quality optimizations in CT of pediatric and adult patients: phantom studies, J. Instrum. 9 (2014) P03013. https://doi.org/10.1088/1748-0221/9/03/P03013
- J.-H. Kim, Y. Choi, K.-S. Joo, B.-S. Sihn, J.-W. Chong, S.E. Kim, K.H. Lee, Y.S. Choe, B.-T. Kim, Development of a miniature scintillation camera using an NaI(Tl) scintillator and PSPMT for scintimammography, Phys. Med. Biol. 45 (2000) 3481-3488. https://doi.org/10.1088/0031-9155/45/11/326
- M. Moszynski, J. Zalipska, M. Balcerzyk, M. Kapusta, W. Mengesha, J.D. Valentine, Intrinsic energy resolution of NaI(Tl), Nucl. Instrum. Methods Phys. Res. A 484 (2002) 259-269. https://doi.org/10.1016/S0168-9002(01)01964-7
Cited by
- X-ray image denoising with fast non-local means (FNLM) approach using acceleration function in CdTe semiconductor photon counting detector (PCD): Monte Carlo simulation study vol.172, pp.None, 2017, https://doi.org/10.1016/j.ijleo.2018.07.051
- Performance evaluation of noise reduction algorithm with median filter using improved thresholding method in pixelated semiconductor gamma camera system: A numerical simulation study vol.51, pp.2, 2017, https://doi.org/10.1016/j.net.2018.10.005
- Effects of total variation regularization noise reduction algorithm in improved K-edge log-subtraction X-ray images with photon-counting cadmium telluride detectors vol.206, pp.None, 2017, https://doi.org/10.1016/j.ijleo.2020.164380