DOI QR코드

DOI QR Code

Formulation of an alternate concrete mix for concrete filled GFRG panels

  • Nandan, Nithya (Department of Civil Engineering, Sree Buddha College of Engineering) ;
  • Renjith, R. (Department of Civil Engineering, Sree Buddha College of Engineering)
  • 투고 : 2016.08.10
  • 심사 : 2016.12.26
  • 발행 : 2017.07.25

초록

Glass fiber reinforced gypsum panels (GFRG) are hollow panels made from modified gypsum plaster and reinforced with chopped glass fibers. The hollow cores of panels can be filled with in-situ concrete/reinforced concrete or insulation material to increase the structural strength or the thermal insulation, respectively. GFRG panels are unfilled when used as partition walls. As load bearing walls, the panels are filled with M 20 grade concrete (reinforced concrete filling) in order to resist the gravity and lateral loads. The study was conducted in two stages: First stage involves formulation of the alternate light weight mix by conducting experimental investigations to obtain the optimum combination of phosphogypsum and shredded thermocol. In the second stage the alternate mixes are filled in GFRG panels and experimental investigations are conducted to compare the performance against panels filled with conventional M 20 mix.

키워드

참고문헌

  1. Bhadauria, S.S. and Thakare, R.B (2006), "Utilis-ation of phosphogypsum in cement mortar and concrete", 31st Conference on Our World in Concrete & Structures, Singapore, August.
  2. Gambhir, M.L. (2010), Concrete Technology Theory and Practice, Mc Graw Hill Education Private Limited, New Delhi, India.
  3. Gawatre Dinesh, W (2013), "Advantages of wastephosphogypsum in concrete", Int. J. Sci. Res., 2(2), 153-154. https://doi.org/10.15373/22778179/FEB2013/51
  4. Geethu, S. and Renjith, R. (2015), "Formulation of an alternate light weight concrete mix for concrete filled glass fiber reinforced gypsum (GFRG) panels", Int. J. Sci. Res., 4(7), 1837-1843.
  5. Herki, B.A., Khatib, J.M. and Negim, E.M. (2013), "Lightweight concrete made from waste polystyrene and fly ash", World Appl. Sci. J., 21(9), 1356-1360.
  6. IS: 10262 (1982), Recommended Guidelines for Concrete Mix Design, Bureau of Indian Standards, New Delhi, India.
  7. IS: 10262 (2009), Recommended Guidelines for Concrete Mix Design, Bureau of Indian Standards, New Delhi, India.
  8. IS: 1199 (1959), Indian Standard Code of Practice Methods of Sampling and Analysis of Concrete, Bureau of Indian Standards, New Delhi, India.
  9. IS: 2386 (Part III) (1963), Indian Standard Code of Practice Methods of Test for Aggregates for Concrete, Bureau of Indian Standards, New Delhi, India.
  10. IS: 383 (1970), Specification for Coarse and Fine Aggregate from Natural Sources for Concrete, Bureau of Indian Standards, New Delhi, India.
  11. IS: 4031-1967(reaffirmed 1995), Methods of Physical Tests for Hydraulic Cement, Bureau of Indian Standards, New Delhi, India.
  12. IS: 456 (2000), Plain and Reinforced Concrete-Code of Practice, Bureau of Indian Standards, New Delhi, India.
  13. IS: 516 (1959), Indian Standard Code of Practice Methods of Test for Strength of Concrete, Bureau of Indian Standards, New Delhi, India.
  14. IS: 8112 (2013), Ordinary Portland cement, 43 Grade Specification, Bureau of Indian Standards, New Delhi, India.
  15. Janardhana, M., Prasad, A.M. and Menon, D. (2006), "Studies on the behavior of glass fiber reinforced gypsum wall panels", Proceedings of the 8th U.S. National Conference on Earthquake Engineering, San Francisco, California, USA, April.
  16. Kan, A. and Demirboga, R. (2009), "A novel material for lightweight concrete production", J. Cement Concrete Compos., 31(7), 1-8. https://doi.org/10.1016/j.cemconcomp.2008.12.001
  17. Kekanovic, M., Kukaras, D., Ceh, A. and Karaman, G. (2014), "Lightweight concrete with recycled ground expanded polystyrene aggregate", Tech. Gazette, 21(2), 309-315
  18. Menon, D. and Meher Prasad, A. (2013), Development of Building Systems Using Glass Fiber Reinforced Gypsum, Master builder ASCE, October.
  19. Structural Design Manual (2013), Use of Glass Fibre Reinforced Gypsum (GFRG) Panels in Buildings, Structural Engineering Division IIT Madras, Chennai, India.
  20. Trussoni, M., Hays, C.D. and Zollo, R.F. (2013), "Comparing lightweight polystyrene concrete using engineered or waste materials", ACI Mater. J., 109(1), 101-107.
  21. Wu, Y.F. (2004), "The effect of longitudinal reinforcement on the cyclic shear behaviour of glass fibre reinforced gypsum wall panels: tests", Eng. Struct., 26(11), 1633-1646. https://doi.org/10.1016/j.engstruct.2004.06.009
  22. Wu, Y.F. (2009), "The structural behavior and design methodology for a new building system consisting of glass fiber reinforced gypsum panels", Constr. Build. Mater., 23(8), 2905-2913. https://doi.org/10.1016/j.conbuildmat.2009.02.026
  23. Wu, Y.F. and Dare, M.P. (2004), "Axial and shear behaviour of glass fibre reinforced gypsum wall panels: tests", J. Compos. Construct., 8(6), 569-578. https://doi.org/10.1061/(ASCE)1090-0268(2004)8:6(569)