References
- Park HS, Kwon TG. Sliding mechanics with microscrew implant anchorage. Angle Orthod 2004;74:703-10.
- Choi SH, Jang SH, Cha JY, Hwang CJ. Evaluation of the surface characteristics of anodic oxidized miniscrews and their impact on biomechanical stability: An experimental study in beagle dogs. Am J Orthod Dentofacial Orthop 2016;149:31-8. https://doi.org/10.1016/j.ajodo.2015.06.020
- Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, Takano-Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 2003;124:373-8. https://doi.org/10.1016/S0889-5406(03)00565-1
- Cheng SJ, Tseng IY, Lee JJ, Kok SH. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 2004;19:100-6.
- Hong SB, Kusnoto B, Kim EJ, BeGole EA, Hwang HS, Lim HJ. Prognostic factors associated with the success rates of posterior orthodontic miniscrew implants: A subgroup meta-analysis. Korean J Orthod 2016;46:111-26. https://doi.org/10.4041/kjod.2016.46.2.111
- Chung CJ, Jung KY, Choi YJ, Kim KH. Biomechanical characteristics and reinsertion guidelines for retrieved orthodontic miniscrews. Angle Orthod 2014;84:878-84. https://doi.org/10.2319/092613-703.1
- Noorollahian S, Alavi S, Rafiei E. The effect of multiple processing and re-use on orthodontic miniscrew torque values. Dent Res J (Isfahan) 2015; 12:243-7.
- Noorollahian S, Alavi S, Monirifard M. A processing method for orthodontic mini-screws reuse. Dent Res J (Isfahan) 2012;9:447-51.
- Choi SH, Cha JY, Joo UH, Hwang CJ. Surface changes of anodic oxidized orthodontic titanium miniscrew. Angle Orthod 2012;82:522-8. https://doi.org/10.2319/071311-448.1
- Cho YC, Cha JY, Hwang CJ, Park YC, Jung HS, Yu HS. Biologic stability of plasma ion-implanted miniscrews. Korean J Orthod 2013;43:120-6. https://doi.org/10.4041/kjod.2013.43.3.120
- Park JH, Olivares-Navarrete R, Baier RE, Meyer AE, Tannenbaum R, Boyan BD, et al. Effect of cleaning and sterilization on titanium implant surface properties and cellular response. Acta Biomater 2012;8:1966-75. https://doi.org/10.1016/j.actbio.2011.11.026
- Cochis A, Fini M, Carrassi A, Migliario M, Visai L, Rimondini L. Effect of air polishing with glycine powder on titanium abutment surfaces. Clin Oral Implants Res 2013;24:904-9. https://doi.org/10.1111/j.1600-0501.2012.02490.x
- Sahrmann P, Ronay V, Sener B, Jung RE, Attin T, Schmidlin PR. Cleaning potential of glycine air-flow application in an in vitro peri-implantitis model. Clin Oral Implants Res 2013;24:666-70. https://doi.org/10.1111/j.1600-0501.2012.02445.x
- Chairay JP, Boulekbache H, Jean A, Soyer A, Bouchard P. Scanning electron microscopic evaluation of the effects of an air-abrasive system on dental implants: a comparative in vitro study between machined and plasma-sprayed titanium surfaces. J Periodontol 1997;68:1215-22. https://doi.org/10.1902/jop.1997.68.12.1215
- Zafar MS, Ahmed N. The effects of acid etching time on surface mechanical properties of dental hard tissues. Dent Mater J 2015;34:315-20. https://doi.org/10.4012/dmj.2014-083
- Kamburis JJ, Barker TH, Barfield RD, Eleazer PD. Removal of organic debris from bovine dentin shavings. J Endod 2003;29:559-61. https://doi.org/10.1097/00004770-200309000-00004
- Eliades T, Zinelis S, Papadopoulos MA, Eliades G. Characterization of retrieved orthodontic miniscrew implants. Am J Orthod Dentofacial Orthop 2009; 135:10.e1-7; discussion 10-1.
- Shank SB, Beck FM, D'Atri AM, Huja SS. Bone damage associated with orthodontic placement of miniscrew implants in an animal model. Am J Orthod Dentofacial Orthop 2012;141:412-8. https://doi.org/10.1016/j.ajodo.2011.10.021
- Yadav S, Upadhyay M, Liu S, Roberts E, Neace WP, Nanda R. Microdamage of the cortical bone during mini-implant insertion with self-drilling and selftapping techniques: a randomized controlled trial. Am J Orthod Dentofacial Orthop 2012;141:538-46. https://doi.org/10.1016/j.ajodo.2011.12.016
- Youn JW, Cha JY, Yu HS, Hwang CJ. Biologic evaluation of a hollow-type miniscrew implant: an experimental study in beagles. Am J Orthod Dentofacial Orthop 2014;145:626-37. https://doi.org/10.1016/j.ajodo.2013.12.028
- Jung UW, Kim S, Kim YH, Cha JK, Lee IS, Choi SH. Osseointegration of dental implants installed without mechanical engagement: a histometric analysis in dogs. Clin Oral Implants Res 2012;23:1297-301. https://doi.org/10.1111/j.1600-0501.2011.02306.x
- Eom TG, Jeon GR, Jeong CM, Kim YK, Kim SG, Cho IH, et al. Experimental study of bone response to hydroxyapatite coating implants: bone-implant contact and removal torque test. Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:411-8. https://doi.org/10.1016/j.oooo.2011.10.036
- Cha JY, Lim JK, Song JW, Sato D, Kenmotsu M, Inoue T, et al. Influence of the length of the loading period after placement of orthodontic miniimplants on changes in bone histomorphology: microcomputed tomographic and histologic analysis. Int J Oral Maxillofac Implants 2009;24:842-9.
- Wei G, Hu Y, Zheng L, Huo J, Tang T, Deng F. Bone remodeling at microscrew interface near extraction site in the beagle dog mandible-histologic and immunohistochemical analyses. J Appl Oral Sci 2013;21:443-51. https://doi.org/10.1590/1679-775720130160
- Oh EJ, Nguyen TD, Lee SY, Jeon YM, Bae TS, Kim JG. Enhanced compatibility and initial stability of Ti6Al4V alloy orthodontic miniscrews subjected to anodization, cyclic precalcification, and heat treatment. Korean J Orthod 2014;44:246-53. https://doi.org/10.4041/kjod.2014.44.5.246
- Chang CS, Lee TM, Chang CH, Liu JK. The effect of microrough surface treatment on miniscrews used as orthodontic anchors. Clin Oral Implants Res 2009;20:1178-84. https://doi.org/10.1111/j.1600-0501.2009.01728.x
Cited by
- Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs) vol.11, pp.7, 2017, https://doi.org/10.3390/ma11071138
- Comparison of the primary stability of orthodontic miniscrews after repeated insertion cycles: vol.91, pp.3, 2017, https://doi.org/10.2319/050120-375.1
- New and Recovered Temporary Anchorage Devices, In Vitro Assessment of Structural and Surface Properties vol.14, pp.21, 2017, https://doi.org/10.3390/ma14216271