DOI QR코드

DOI QR Code

Correlation between the 2-Dimensional Extent of Orbital Defects and the 3-Dimensional Volume of Herniated Orbital Content in Patients with Isolated Orbital Wall Fractures

  • Cha, Jong Hyun (Department of Plastic and Reconstructive Surgery, Konyang University Hospital, University of Konyang College of Medicine, Myunggok Medical Research Center) ;
  • Moon, Myeong Ho (Biomedical Engineering, Konyang University College of Medicine) ;
  • Lee, Yong Hae (Department of Plastic and Reconstructive Surgery, Konyang University Hospital, University of Konyang College of Medicine, Myunggok Medical Research Center) ;
  • Koh, In Chang (Department of Plastic and Reconstructive Surgery, Konyang University Hospital, University of Konyang College of Medicine, Myunggok Medical Research Center) ;
  • Kim, Kyu Nam (Department of Plastic and Reconstructive Surgery, Konyang University Hospital, University of Konyang College of Medicine, Myunggok Medical Research Center) ;
  • Kim, Chang Gyun (Department of Plastic and Reconstructive Surgery, Konyang University Hospital, University of Konyang College of Medicine, Myunggok Medical Research Center) ;
  • Kim, Hoon (Department of Plastic and Reconstructive Surgery, Konyang University Hospital, University of Konyang College of Medicine, Myunggok Medical Research Center)
  • Received : 2016.10.10
  • Accepted : 2017.01.06
  • Published : 2017.01.20

Abstract

Background The purpose of this study was to assess the correlation between the 2-dimensional (2D) extent of orbital defects and the 3-dimensional (3D) volume of herniated orbital content in patients with an orbital wall fracture. Methods This retrospective study was based on the medical records and radiologic data of 60 patients from January 2014 to June 2016 for a unilateral isolated orbital wall fracture. They were classified into 2 groups depending on whether the fracture involved the inferior wall (group I, n=30) or the medial wall (group M, n=30). The 2D area of the orbital defect was calculated using the conventional formula. The 2D extent of the orbital defect and the 3D volume of herniated orbital content were measured with 3D image processing software. Statistical analysis was performed to evaluate the correlations between the 2D and 3D parameters. Results Varying degrees of positive correlation were found between the 2D extent of the orbital defects and the 3D herniated orbital volume in both groups (Pearson correlation coefficient, 0.568-0.788; $R^2=32.2%-62.1%$). Conclusions Both the calculated and measured 2D extent of the orbital defects showed a positive correlation with the 3D herniated orbital volume in orbital wall fractures. However, a relatively large volume of herniation (>$0.9cm^3$) occurred not infrequently despite the presence of a small orbital defect (<$1.9cm^2$). Therefore, estimating the 3D volume of the herniated content in addition to the 2D orbital defect would be helpful for determining whether surgery is indicated and ensuring adequate surgical outcomes.

Keywords

References

  1. Burm JS, Chung CH, Oh SJ. Pure orbital blowout fracture: new concepts and importance of medial orbital blowout fracture. Plast Reconstr Surg 1999;103:1839-49. https://doi.org/10.1097/00006534-199906000-00005
  2. Manson PN, Grivas A, Rosenbaum A, et al. Studies on enophthalmos: II. The measurement of orbital injuries and their treatment by quantitative computed tomography. Plast Reconstr Surg 1986;77:203-14. https://doi.org/10.1097/00006534-198602000-00005
  3. Park MS, Kim YJ, Kim H, et al. Prevalence of diplopia and extraocular movement limitation according to the location of isolated pure blowout fractures. Arch Plast Surg 2012;39: 204-8. https://doi.org/10.5999/aps.2012.39.3.204
  4. Hwang K, Huan F, Hwang PJ. Diplopia and enophthalmos in blowout fractures. J Craniofac Surg 2012;23:1077-82. https://doi.org/10.1097/SCS.0b013e31824e591d
  5. Fan X, Li J, Zhu J, et al. Computer-assisted orbital volume measurement in the surgical correction of late enophthalmos caused by blowout fractures. Ophthal Plast Reconstr Surg 2003;19:207-11. https://doi.org/10.1097/01.IOP.0000062848.26273.E5
  6. Burnstine MA. Clinical recommendations for repair of isolated orbital floor fractures: an evidence-based analysis. Ophthalmology 2002;109:1207-10. https://doi.org/10.1016/S0161-6420(02)01057-6
  7. Sung YS, Chung CM, Hong IP. The correlation between the degree of enophthalmos and the extent of fracture in medial wall fracture left untreated for over six months: a retrospective analysis of 81 cases at a single institution. Arch Plast Surg 2013;40:335-40. https://doi.org/10.5999/aps.2013.40.4.335
  8. Jin HR, Shin SO, Choo MJ, et al. Relationship between the extent of fracture and the degree of enophthalmos in isolated blowout fractures of the medial orbital wall. J Oral Maxillofac Surg 2000;58:617-20. https://doi.org/10.1016/S0278-2391(00)90152-6
  9. Whitehouse RW, Batterbury M, Jackson A, et al. Prediction of enophthalmos by computed tomography after 'blow out' orbital fracture. Br J Ophthalmol 1994;78:618-20. https://doi.org/10.1136/bjo.78.8.618
  10. Bite U, Jackson IT, Forbes GS, et al. Orbital volume measurements in enophthalmos using three-dimensional CT imaging. Plast Reconstr Surg 1985;75:502-8. https://doi.org/10.1097/00006534-198504000-00009
  11. Lee WT, Kim HK, Chung SM. Relationship between small-size medial orbital wall fracture and late enophthalmos. J Craniofac Surg 2009;20:75-80. https://doi.org/10.1097/SCS.0b013e318190df0d
  12. Kwon J, Barrera JE, Most SP. Comparative computation of orbital volume from axial and coronal CT using three-dimensional image analysis. Ophthal Plast Reconstr Surg 2010;26:26-9. https://doi.org/10.1097/IOP.0b013e3181b80c6a
  13. Weissheimer A, Menezes LM, Sameshima GT, et al. Imaging software accuracy for 3-dimensional analysis of the upper airway. Am J Orthod Dentofacial Orthop 2012;142: 801-13. https://doi.org/10.1016/j.ajodo.2012.07.015
  14. Feeman TG. The mathematics of medical imaging: a beginner's guide. New York: Springer; 2010.
  15. Ploder O, Klug C, Backfrieder W, et al. 2D- and 3D-based measurements of orbital floor fractures from CT scans. J Craniomaxillofac Surg 2002;30:153-9. https://doi.org/10.1054/jcms.2002.0296
  16. Yano H, Nakano M, Anraku K, et al. A consecutive case review of orbital blowout fractures and recommendations for comprehensive management. Plast Reconstr Surg 2009; 124:602-11. https://doi.org/10.1097/PRS.0b013e3181addbbd
  17. Choi KE, Lee J, Lee H, et al. The paradoxical predominance of medial wall injuries in blowout fracture. J Craniofac Surg 2015;26:e752-5. https://doi.org/10.1097/SCS.0000000000002208
  18. Koo L, Hatton MP, Rubin PA. When is enophthalmos "significant"? Ophthal Plast Reconstr Surg 2006;22:274-7. https://doi.org/10.1097/01.iop.0000226865.22184.6a
  19. Park MS, Baek S. Measurement of fracture size using the picture archiving communication system in an outpatient clinic for factors that influence postoperative enophthalmos in adult inferior orbital wall fractures. J Craniofac Surg 2013; 24:1692-4. https://doi.org/10.1097/SCS.0b013e3182801be4
  20. Deveci M, Ozturk S, Sengezer M, et al. Measurement of orbital volume by a 3-dimensional software program: an experimental study. J Oral Maxillofac Surg 2000;58:645-8. https://doi.org/10.1016/S0278-2391(00)90157-5
  21. Hinkle DE, Wiersma W, Jurs SG. Applied statistics for the behavioral sciences. 5th ed. Boston: Houghton Mifflin Company; 2003.
  22. Ploder O, Klug C, Voracek M, et al. A computer-based method for calculation of orbital floor fractures from coronal computed tomography scans. J Oral Maxillofac Surg 2001;59:1437-42. https://doi.org/10.1053/joms.2001.28278
  23. Parsons GS, Mathog RH. Orbital wall and volume relationships. Arch Otolaryngol Head Neck Surg 1988;114:743-7. https://doi.org/10.1001/archotol.1988.01860190047020
  24. Rhee SH, Kim TS, Song JM, et al. Effectiveness of computed tomography for blow-out fracture. Maxillofac Plast Reconstr Surg 2014;36:273-9. https://doi.org/10.14402/jkamprs.2014.36.6.273

Cited by

  1. Repair of Lower Canalicular Laceration Using the Mini-Monoka Stent : Primary and Revisional Repairs vol.29, pp.4, 2017, https://doi.org/10.1097/scs.0000000000004423
  2. Delayed reconstruction of posttraumatic facial deformities vol.61, pp.12, 2018, https://doi.org/10.5124/jkma.2018.61.12.740
  3. Prediction of late displacement of the globe in orbital blowout fractures vol.98, pp.2, 2017, https://doi.org/10.1111/aos.14226
  4. Restoration of the inferomedial orbital strut using a standardized three‐dimensional printing implant vol.236, pp.5, 2020, https://doi.org/10.1111/joa.13136
  5. Comparison of Efficacy between Three-Dimensional Printing and Manual-Bending Implants for Inferomedial Orbital Fracture: A Retrospective Study vol.11, pp.17, 2017, https://doi.org/10.3390/app11177971