DOI QR코드

DOI QR Code

Design principles for stiffness-tandem energy dissipation coupling beam

  • Sun, Baitao (Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration) ;
  • Wang, Mingzhen (Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration) ;
  • Gao, Lin (College of Architecture Engineering, Chongqing University of Arts and Sciences)
  • Received : 2016.12.22
  • Accepted : 2017.05.25
  • Published : 2017.07.25

Abstract

Reinforced concrete shear wall is one of the most common structural forms for high-rise buildings, and seismic energy dissipation techniques, which are effective means to control structural vibration response, are being increasingly used in engineering. Reinforced concrete-mild steel damper stiffness-tandem energy dissipation coupling beams are a new technology being gradually adopted by more construction projects since being proposed. Research on this technology is somewhat deficient, and this paper investigates design principles and methods for two types of mild steel dampers commonly used for energy dissipation coupling beams. Based on the conception design of R.C. shear wall structure and mechanics principle, the basic design theories and analytic expressions for the related optimization parameters of dampers at elastic stage, yield stage, and limit state are derived. The outcomes provide technical support and reference for application and promotion of reinforced concrete-mild steel damper stiffness-tandem energy dissipation coupling beam in engineering practice.

Keywords

References

  1. Bengar, H.A. and Aski, R.M. (2016), "Performance based evaluation of RC coupled shear wall system with steel coupling beam", Steel Compos. Struct., 20(2), 337-355. https://doi.org/10.12989/scs.2016.20.2.337
  2. Chao, P. and Dagen, W. (2012), "Seismic analysis and design of damping controlled coupled shear wall with vertical dampers in coupling beams", J. Build. Struct., 33(10), 39-46. (in Chinese)
  3. Duan, C. (2011), "Study on Practical Technologies for Earthquake Safe Community", Master Dissertation, Institute of Engineering Mechanics, China Earthquake Administration. (in Chinese)
  4. Fang, E. (1985), "The elastic-plastic performance effect on the coupled shear walls caused by coupling beams", Earthq. Resistant, 4(5). (in Chinese)
  5. Fortney, P.J., Shahrooz, B.M. and Rassati, G.A. (2007), "Largescale testing of a replaceable 'fuse' steel coupling beam", J. Struct. Eng.-ASCE, 133(12),1801-1807. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:12(1801)
  6. Fujiang, Q.J.X. (2006), "Displacement-based deformation capacity design method of reinforced concrete coupling beams", Build. Struct., 36(1),63-65. (in Chinese)
  7. GB 50011-2010. (2010), Code for Seismic design of buildings, Ministry of Housing and Urban-Rural Development of the People's Republic of China, Beijing.
  8. Hemsas, M., Elachachi, S.M. and Breysse, D. (2014), "Seismic response and damage development analyses of an RC structural wall building using macro-element", Struct. Eng. Mech., 51(3), 447-470. https://doi.org/10.12989/sem.2014.51.3.447
  9. Heresi, P., Herrera, R.A. and Moroni, M.O. (2014) "Testing and modelling of shape memory alloy plates for energy dissipators", Smart Struct. Syst., 14(5), 883-900. https://doi.org/10.12989/sss.2014.14.5.883
  10. Kumagai, H. (2010), Earthquake Response of a High-Rise Building with Reinforced Concrete Shear Walls and Coupling Beam Dampers, Japan Shimizu Corporation research report, No. 87 January, 39-48. (in Japanese)
  11. Li, A. (1992), "Research of aseismic control and it control devices for reinforced concrete shear wall structure", Ph.D. Dissertation, Southeast University of China.(in Chinese)
  12. Li, D. (2013), "Design and seismic analysis of metal damper on bisected R.C. shear wall coupling beam", Master Dissertation, Dalian University of Technology of China. (in Chinese)
  13. Liang, X., Dong, Z. and Wang, Y. (2009), "Damage to tall buildings in areas with large epicentral distance during M8.0 Wenchuan earthquake", J. Earthq. Eng. Eng. Vib., 29(1),24-31. (in Chinese)
  14. Mao, C.X., Wang, Z.Y., Zhang, L.Q. et al. (2012), "Seismic performance of RC frame-shear wall structure with novel shape memory alloy dampers in coupling beams", 15WCEE, Lisbon, Portugal, Paper-ID: 4988 ,September 24-28.
  15. Nestorovic, T., Trajkov, M. and Garmabi, S. (2015), "Optimal placement of piezoelectric actuators and sensors on a smart beam and a smart plate using multi-objective genetic algorithm", Smart Struct. Syst., 15(4), 1041-1062. https://doi.org/10.12989/sss.2015.15.4.1041
  16. Paulay, T. and Binney, J.R. (1974), "Diagonally reinforced coupling beams of shear walls, shear in reinforced concrete", ACI Special PublicationSP 42, Detroit, Vol. I, 579-598.
  17. Paulay, T. and Priestley, M.J.N. (1992), Seismic Design of Reinforced Concrete and Masonry Buildings, John Wiley & Sons, New York.
  18. Saad, G., Najjar, S. and Saddik, F. (2016), "Seismic performance of reinforced concrete shear wall buildings with underground stories", Eartq. Struct., 10(4), 965-988. https://doi.org/10.12989/eas.2016.10.4.965
  19. Stephens, R.I., Fatemi, A., Stephens, R.R. et al. (2001), Metal Fatigue in Engineering - Second Edition, Jonh Wiley & Sons, Inc.
  20. Tegos, I.A. Penelis, G.G. (1998), "Seismic resistance of short columns and coupling beams reinforced with inclined bars", ACI Struct. J., 85(1),82-88.
  21. Ying, Z. And Xilin, L. (2011), "Lessons learnt from damages of reinforced concrete Chile earthquake and revelations to structural design in China", J. Build. Struct., 32(5),17-23. (in Chinese)
  22. Yukinobu, K., Masami, T., Hiroki, S. And Kazushi, S. (2002), "Study on coupling beams using low strength steel part 1 :Test program and static cyclic loading test", Architectural Institute of Japan convention academic lecture synopsis Collection (Hokuriku), 08,1031-1032.(in Japanese)
  23. Zhang, D., Wang, J., Li, B. and Shi, B. (2016), "Fatigue characteristics of distributed sensing cables under low cycle elongation", Smart Struct. Syst., 18(6), 1203-1215. https://doi.org/10.12989/sss.2016.18.6.1203