An Examination of Load Cut-off Effect Using Modern Buildings in Korean Traditional Passive Methods

  • Kim, Hwan-yong (Department of Architectural Engineering, ERI, Gyeongsang National University) ;
  • Song, Young-hak (Department of Architectural Engineering, ERI, Gyeongsang National University) ;
  • Kim, Hyemi (Graduated School, Department of Architectural Engineering, Gyeongsang National University)
  • Received : 2017.01.24
  • Accepted : 2017.03.13
  • Published : 2017.06.30

Abstract

Recently, as a new perspective to view the architecture in relation to global environmental problems, interest in environmental architecture that conforms to the surrounding environment and nature with nature has been expanded as a part of the natural ecosystem, rather than seeing the building as an independent entity. Traditional Korean architecture creates a comfortable indoor environment by appropriately using the natural energy around, ranging from the arrangement of the building and the space composition to the use of detailed materials and to harmonize the artificial architectural environment without harming the natural ecosystem. The purpose of this study is to propose a method to apply the environmental control techniques of traditional buildings to modern buildings. As a research method, the characteristics of Korean traditional buildings according to the climatic characteristics of Korea were recognized through existing literature data and when applied to methods of traditional buildings, ventilation systems, control through eaves, and humidity control using Hanji the effect of energy load control on traditional buildings was analyzed and identified through existing literature. After analyzing the problems of modern architecture, we analyzed the effect of the environmental control system of traditional architecture on modern architecture. Simulation results show that the application of the environmental control system of traditional buildings to modern buildings reduces the cooling and heating load of modern buildings and has an effect on humidity control. This study suggests that quantitative energy saving will be possible if the environmental control techniques of traditional buildings are appropriately applied to modern buildings.

Keywords

References

  1. Jeong-min C et al. (1993) A study on the effect of external shading device on the building load. Competition Journal of Architectural Institute of Korea, Vol13, No1 : 267-270.
  2. Gil-su J. (2006) An experimental study on a effect of Hanji windows on indoor air temperature and humidity control. Journal of the Korea Housing Association, Vol 17, No2 : 125-134.
  3. Gun-ju J. (2006) Comparison on Environmental Performances of Cooling and Heating Energies for Building Directions in Apartment House Using by Energy Plus. Competition Journal of Architectural Institute of Korea, Vol8, NO2 : 65-70.
  4. Doo-woon J. & Hyun-woo L. (2000) A study on the sunshine hours and the heating expenses in apartment building with different arrangement. Journal of Architectural Institute of Korea, Vol16, No9 : 205-211.
  5. Jeong-min K. (2005) A Comparative Study on the Cross-Ventilation Effect by the Floor Plan Type of Apartment House during Summer. Journal of the Korea Housing Association, Vol2 : 301-306.
  6. Sang-kyu, N (2001) An Impact Analysis on the Heating Energy by Sunlight Environment of Apartment House, Master of Suwon Universty
  7. Gyeong-hoe L. (1993) Passive environmental control in Korean traditional architectural and modernization of the principle. Journal of Architectural Institute of Korea, Vol37, No5 : 8-15.
  8. Jin-u P. & Hyeon-jun M. (2008) An analysis of moisture transportation performance on a Korean traditional double wall system using computer simulation. Journal of Architectural Institute of Korea.