Purpose: This study aimed to evaluate the adherence to the clinical guideline for endotracheal suction in nurses working at intensive care units (ICU) and to identify the characteristics of nurses with good adherence. Methods: This study was a descriptive study to evaluate the pattern of adherence and its related factors to endotracheal suction. One hundred fifty five nurses working at ICU participated in this study. We used a questionnaire developed based on American Association for Respiratory Care (AARC) guidelines and other associated factors from previous studies. Results: Around half of the participants reported that their adherence to the clinical guideline was poor. Items deviated from the recommended guideline were reasons for initiating a suctioning, applied suction pressure ranged from 20 to 200mmHg, and applied catheter size from 6 to 17 french. Other factors deviated were the depth of inserted catheter, and inappropriate use of normal saline instillation. The most significant factor was related to hospital; the misused or misled clinical protocol. Conclusions: The adherence to the clinical guidelines of the endotracheal suction in ICU nurses was not appropriate, which might contribute to the patient health outcomes. More enhanced continuing education as well as hospital regulation is warranted.

Keywords

References

  1. American Association for Respiratory Care. AARC Clinical Practice Guidelines. Endotracheal suctioning of mechanically ventilated patients with artificial airways 2010. Respiratory Care. 2010; 55: 758-764. http://rc.rcjournal.com/content/55/6/758.short
  2. Chang SJ, & Song MS. Knowledge and Management of Tracheal Tube Cuffs Among ICU Nurses in Korea. Korean Journal of Adult Nursing. 2009; 21(6): 270-279.
  3. John RE, Seckel MA. AACN Protocols for Practice: Care of the Mechanically Ventilated Patient(2nd ed.). Aliso Viejo, CA: Jones and Bartlett Publishers. 2007
  4. Paratz JD. Stockton KA. Efficacy and safety of normal saline instillation: A systematic review. Physiotherapy. 2009; 95(4): 241-250. https://doi.org/10.1016/j.physio.2009.06.002
  5. Rimensberger P. Pediatric and Neonatal Mechanical Ventilation: from basics to clinical practice. Springer Berlin Heidelberg. 2015 pp. 687-710. DOI 10.1007/978-3-642-01219-8_24
  6. Hemida SA. Prevention of Endotracheal Suctioning-Related Complications: a Comparison between Manual and Ventilator Hyperinflation/Hyperoxygenation. International Journal of Nursing Education. 2015;7(1): 241-248. DOI : 10.5958/0974-9357.2015.00050.1
  7. Mohammadpour A, Amini S, Shakeri MT, Mirzaei S. Comparing the effect of open and closed endotracheal suctioning on pain and oxygenation in post CABG patients under mechanical ventilation. Iranian Journal of Nursing and Midwifery Research. 2015;20(2):195-199.
  8. Seo MS, Park KS. A Comparison of the Opened Versus Closed-System of Suctioning -In Oxygen Saturation, Vital Signs and Suction Time. Korean Journal of Adult Nursing. 2009; 21(2): 141-154.
  9. Roberts FE. Consensus among physiotherapists in the united kingdom on the use of normal saline instillation prior to endotracheal suction: a Delphi study. Physiotherapy Canada. 2009; 61(2): 107-115. https://doi.org/10.3138/physio.61.2.107
  10. Zahran, E. M., & Abd El Razik, A. A. (2011). Tracheal suctioning with versus without saline instillation. Journal of American Science, 7(8), 23-32.
  11. Nakstad ER. Opdahl H, Heyerdahl F, Borchsenius F, & Skjonsberg OH. Can ventilator settings reduce the negative effects of endotracheal suctioning? Investigations in a mechanical lung model. BMC Anesthesiology. 2016; 16(1): 30. DOI: 10.1186/s12871-016-0196-z Opdahl H, Heyerdahl F, Borchsenius F, & Skjonsberg OH. Can ventilator settings reduce the negative effects of endotracheal suctioning? Investigations in a mechanical lung model. BMC Anesthesiology. 2016; 16(1): 30. DOI: 10.1186/s12871-016-0196-z
  12. Overend TJ, Anderson CM, Brooks D, Cicutto L, Keim M, McAuslan D, et al. Updating the evidence base for suctioning adult patients: A systematic review. Canadian Respiratory Journal. 2009; 16(3): e6-e17. https://doi.org/10.1155/2009/872921
  13. Pedersen CM, Rosendahl-Nielsen M, Hjermind J, Egerod I. Endotracheal suctioning of the adult intubated patient-What is the evidence?. Intensive and Critical Care Nursing. 2009; 25(1): 21-30. https://doi.org/10.1016/j.iccn.2008.05.004
  14. Ansari A, Alavi NM, Adib-Hajbagheri M, & Afazel M. The gap between knowledge and practice in standard Endo-tracheal suctioning of ICU nurses, Shahid Beheshti Hospital. Critical Care Nurse. 2012; 5(2): 71-76. http://inhc.ir/article-1-431-en.html
  15. Jansson M, Ala-Kokko T, Ylipalosaari P, & Kyngas H. Evaluation of endotracheal-suctioning practices of critical care nurses - An observational correlation study. Journal of Nursing Education and Practice. 2013; 3(7): 99-105.
  16. Park HJ, Choi YA, Kim KM. A Study on Nurses' Ability to Perform Endotracheal Suction. Journal of Korean Academy of Fundamental Nursing. 2001; 8(3): 379-390.
  17. Kelleher S, Andrews T. An observational study on the open-system endotracheal suctioning practices of critical care nurses. Journal of Clinical Nursing. 2008; 17:: 360-369. https://doi.org/10.1111/j.1365-2702.2007.01990.x