DOI QR코드

DOI QR Code

The effects of non-thermal plasma and conventional treatments on the bond strength of fiber posts to resin cement

  • do Prado, Maira (Metallurgical and Materials Engineering, Federal University of Rio de Janeiro) ;
  • da Silva, Eduardo Moreira (Analytical Laboratory of Restorative Biomaterials - LABiom-R, School of Dentistry, Federal Fluminense University) ;
  • Marques, Juliana das Neves (Metallurgical and Materials Engineering, Federal University of Rio de Janeiro) ;
  • Gonzalez, Caroline Brum (Department of Dental Clinics, Federal University of Rio de Janeiro) ;
  • Simao, Renata Antoun (Metallurgical and Materials Engineering, Federal University of Rio de Janeiro)
  • Received : 2016.09.24
  • Accepted : 2017.02.11
  • Published : 2017.05.31

Abstract

Objectives: This study compared the effect of hexamethyldisiloxane (HMDSO) and ammonia ($NH_3$) plasmas on the bond strength of resin cement to fiber posts with conventional treatments. Materials and Methods: Sixty-five fiber posts were divided into 5 groups: Control (no surface treatment); $H_2O_2$ (24% hydrogen peroxide for 1 min); Blasting (blasting with aluminum oxide for 30 sec); $NH_3$ ($NH_3$ plasma treatment for 3 min); HMDSO (HMDSO plasma treatment for 15 min). After the treatments, the Ambar adhesive (FGM Dental Products) was applied to the post surface (n = 10). The fiber post was inserted into a silicon matrix that was filled with the conventional resin cement Allcem Core (FGM). Afterwards, the post/cement specimens were cut into discs and subjected to a push-out bond strength (POBS) test. Additionally, 3 posts in each group were evaluated using scanning electron microscopy. The POBS data were analyzed by one-way analysis of variance and the Tukey's honest significant difference post hoc test (${\alpha}=0.05$). Results: The Blasting and $NH_3$ groups showed the highest POBS values. The HMDSO group showed intermediate POBS values, whereas the Control and $H_2O_2$ groups showed the lowest POBS values. Conclusion: Blasting and $NH_3$ plasma treatments were associated with stronger bonding of the conventional resin cement Allcem to fiber posts, in a procedure in which the Ambar adhesive was used.

Keywords

References

  1. Reeh ES, Messer HH, Douglas WH. Reduction in tooth stiffness as a result of endodontic and restorative procedure. J Endod 1989;15:512-516. https://doi.org/10.1016/S0099-2399(89)80191-8
  2. Garoushi S, Vallittu PK, Lassila LV. Direct restoration of severely damaged incisors using short fiber-reinforced composite resin. J Dent 2007;35:731-736. https://doi.org/10.1016/j.jdent.2007.05.009
  3. Varlan C, Dimitriu B, Varlan V, Bodnar D, Suciu I. Current opinions concerning the restoration of endodontically treated teeth: basic principles. J Med Life 2009;2:165-172.
  4. Yavirach P, Chaijareenont P, Boonyawan D, Pattamapun K, Tunma S, Takahashi H, Arksornnukit M. Effects of plasma treatment on the shear bond strength between fiber-reinforced composite posts and resin composite for core build-up. Dent Mater J 2009;28:686-692. https://doi.org/10.4012/dmj.28.686
  5. Asmussen E, Peutzfeldt A, Heitmann T. Stiffness, elastic limit, and strength of newer types of endodontic posts. J Dent 1999;27:275-278. https://doi.org/10.1016/S0300-5712(98)00066-9
  6. Vichi A, Grandini S, Davidson CL, Ferrari M. An SEM evaluation of several adhesive systems used for bonding fiber posts under clinical conditions. Dent Mater 2002;18:495-502. https://doi.org/10.1016/S0109-5641(01)00065-3
  7. Monticelli F, Toledano M, Tay FR, Sadek FT, Goracci C, Ferrari M. A simple etching technique for improving the retention of fiber posts to resin composites. J Endod 2006;32:44-47. https://doi.org/10.1016/j.joen.2005.10.005
  8. Monticelli F, Osorio R, Sadek FT, Radovic I, Toledano M, Ferrari M. Surface treatments for improving bond strength to prefabricated fiber posts: a literature review. Oper Dent 2008;33:346-355. https://doi.org/10.2341/07-86
  9. de Sousa Menezes M, Queiroz EC, Soares PV, Faria-e-Silva AL, Soares CJ, Martins LR. Fiber post etching with hydrogen peroxide: effect of concentration and application time. J Endod 2011;37:398-402. https://doi.org/10.1016/j.joen.2010.11.037
  10. Naves LZ, Santana FR, Castro CG, Valdivia AD, Da Mota AS, Estrela C, Correr-Sobrinho L, Soares CJ. Surface treatment of glass fiber and carbon fiber posts: SEM characterization. Microsc Res Tech 2011;74:1088-1092. https://doi.org/10.1002/jemt.20999
  11. Elsaka SE. Influence of chemical surface treatments on adhesion of fiber posts to composite resin core materials. Dent Mater 2013;29:550-558. https://doi.org/10.1016/j.dental.2013.03.004
  12. Liu C, Liu H, Qian YT, Zhu S, Zhao SQ. The influence of four dual-cure resin cements and surface treatment selection to bond strength of fiber post. Int J Oral Sci 2014;6:56-60. https://doi.org/10.1038/ijos.2013.83
  13. Costa Dantas MC, do Prado M, Costa VS, Gaiotte MG, Simao RA, Bastian FL. Comparison between the effect of plasma and chemical treatments on fiber post surface. J Endod 2012;38:215-218. https://doi.org/10.1016/j.joen.2011.10.020
  14. Spyrides SM, Prado Md, Simao RA, Bastian FL. Effect of plasma and fiber position on flexural properties of a polyethylene fiber-reinforced composite. Braz Dent J 2015;26:490-496. https://doi.org/10.1590/0103-644020130225
  15. Prado Md, Roizenblit RN, Pacheco LV, Barbosa CA, Lima CO, Simao RA. Effect of argon plasma on root dentin after use of 6% NaOCl. Braz Dent J 2016;27:41-45. https://doi.org/10.1590/0103-6440201600486
  16. Garcia-Perez T, Rodriguez E, Bittencourt E, Jova Z. Activation of HMDSO thin film with low pressure argon plasma and vaccum ultraviolet radiation. Lat Am Appl Res 2012;42:19-25.
  17. Spyrides SM, Prado Md, Araujo JR, Simao RA, Bastian FL. Effects of plasma on polyethylene fiber surface for prosthodontic application. J Appl Oral Sci 2015;23:614-622. https://doi.org/10.1590/1678-775720150260
  18. Hayakawa T, Yoshinari M, Nemoto K. Characterization and protein-adsorption behavior of deposited organic thin film onto titanium by plasma polymerization with hexamethyldisiloxane. Biomaterials 2004;25:119-127. https://doi.org/10.1016/S0142-9612(03)00484-8
  19. Vautrin-UI C, Boisse-Laporteb C, Benissadb N, Chaussea A, Leprinceb P, Messinaa R. Plasma-polymerized coatings using HMDSO precursor for iron protection. Prog Org Coat 2000;38:9-15. https://doi.org/10.1016/S0300-9440(99)00077-6
  20. Fernandes JCS, Ferreria MGS, Haddaw DB, Goruppa A, Short R, Dixon DG. Plasma-polymerized coatings used as pre-treatment for aluminum alloys. Surf Coat Technol 2002;154:8-13. https://doi.org/10.1016/S0257-8972(01)01705-4
  21. Gengenbach TR, Xie X, Chatelier RC, Griesser HJ. Evolution of the surface composition and topography of perfluorinated polymers following ammonia-plasma treatment. J Adhes Sci Technol 1994;8:305-328. https://doi.org/10.1163/156856194X00267
  22. Wu DY, Gutowski WS, Li S, Griesser HJ. Ammonia plasma treatment of polyolefins for adhesive bonding with a cyanoacrylate adhesive. J Adhes Sci Technol 1995;9:501-525. https://doi.org/10.1163/156856195X00428
  23. Yang J, Bei J, Wang S. Improving cell affinity of poly(D,L-lactide) film modified by anhydrous ammonia plasma treatment. Polym Adv Technol 2002;13:220-226. https://doi.org/10.1002/pat.177
  24. Arrais CA, Pontes FM, Santos LP, Leite ER, Giannini M. Degree of conversion of adhesive systems light-cured by LED and halogen light. Braz Dent J 2007;18:54-59. https://doi.org/10.1590/S0103-64402007000100012
  25. Paiva DL, Lampman GM, Kriz GS, Vyvyan JR. Introduction to spectroscopy. 4th ed. California: Cengage Learning; 2008. p15-86.
  26. Van Landuyt KL, Yoshida Y, Hirata I, Snauwaert J, De Munck J, Okazaki M, Suzuki K, Lambrechts P, Van Meerbeek B. Influence of the chemical structure of functional monomers on their adhesive performance. J Dent Res 2008;87:757-761. https://doi.org/10.1177/154405910808700804
  27. Chen M, Zhang Y, Sky Driver M, Caruso AN, Yu Q, Wang Y. Surface modification of several dental substrates by non-thermal, atmospheric plasma brush. Dent Mater 2013;29:871-880. https://doi.org/10.1016/j.dental.2013.05.002
  28. Ritts AC, Li H, Yu Q, Xu C, Yao X, Hong L, Wang Y. Dentin surface treatment using a non-thermal argon plasma brush for interfacial bonding improvement in composite restoration. Eur J Oral Sci 2010;118:510-516. https://doi.org/10.1111/j.1600-0722.2010.00761.x
  29. Pan J, Sun K, Liang Y, Sun P, Yang X, Wang J, Zhang J, Zhu W, Fang J, Becker KH. Cold plasma therapy of a tooth root canal infected with Enterococcus faecalis biofilms in vitro. J Endod 2013;39:105-110. https://doi.org/10.1016/j.joen.2012.08.017
  30. Mercx FPM. Improved adhesive properties of highmodulus polyethylene structures: 3. Air- and ammoniaplasma treatment. Polym 1994;35:2098-2107. https://doi.org/10.1016/0032-3861(94)90234-8

Cited by

  1. Non-thermal plasma treatment to enhance the adhesion between enamel surface and orthodontic bracket vol.30, pp.4, 2019, https://doi.org/10.3233/bme-191065
  2. The Oleofobization of Paper via Plasma Treatment vol.13, pp.13, 2017, https://doi.org/10.3390/polym13132148