References
- Barroso, L.R., Chase, J.G. and Hunt, S. (2003), "Resettable smart dampers for multi-level seismic hazard mitigation of steel moment frames", J. Struct.Control, 10(1), 41-58. https://doi.org/10.1002/stc.16
- Beziat, A., Munoz, A.M., Chase, J.G., MacRae, G.A., Rodgers, G. W. and Clifton, C. (2012), "Performance analysis of energy dissipators and isolators placed in bridges to prevent structural damage in columns", J. Earthq. Eng., 16(8), 1113-1131. https://doi.org/10.1080/13632469.2012.713561
- Bitaraf, M., Barroso, L.R. and Hurlebaus, S. (2010a), "Adaptive control to mitigate damage impact on structural response", J. Intel. Mat. Syst. Str., 21(6), 607-619. https://doi.org/10.1177/1045389X10361993
- Bitaraf, M. and Hurlebaus, S. (2013), "Semi-active adaptive control of seismically excited 20-story nonlinear building", Eng. Struct., 56, 2107-2118. https://doi.org/10.1016/j.engstruct.2013.08.031
- Bitaraf, M., Hurlebaus, S. and Barroso, L.R. (2012), "Active and semi-active adaptive control for undamaged and damaged building structures under seismic load", Comput. - Aided Civil Infrastruct. Eng., 27(1), 48-64. https://doi.org/10.1111/j.1467-8667.2011.00719.x
- Bitaraf, M., Ozbulut, O.E., Hurlebaus, S. and Barroso, L. (2010b), "Application of semi-active control strategies for seismic protection of buildings with MR dampers", Eng. Struct., 32(10), 3040-3047. https://doi.org/10.1016/j.engstruct.2010.05.023
- Bobrow, J.E., Jabbari, F. and Thai, K. (2000), "A new approach to shock isolation and vibration suppression using a resetable actuator", ASME Transactions on Dynamic Systems, Measurement, and Control., 122(3), 570-573. https://doi.org/10.1115/1.1286629
- Caterino, N., Spizzuoco, M. and Occhiuzzi, A. (2015), "Shaking table testing of a steel frame structure equipped with semiactive MR dampers: comparison of control algorithms", Smart Struct. Syst., 15(4), 963-995. https://doi.org/10.12989/sss.2015.15.4.963
- Chase, J.G., Barroso, L.R. and Hunt, S. (2004), "The impact of total acceleration control for semi-active earthquake hazard mitigation", Eng. Struct., 26(2), 201-209. https://doi.org/10.1016/j.engstruct.2003.09.008
- Chase, J.G., Mulligan, K.J., Gue, A., Alnot, T., Rodgers, G., Mander, J.B., Elliott, R., Deam, B., Cleeve, L. and Heaton, D. (2006), "Re-shaping hysteretic behaviour using semi-active resettable device dampers", Eng. Struct., 28(10), 1418-1429. https://doi.org/10.1016/j.engstruct.2006.01.011
- Chen, X.Q., Chase, J.G., Mulligan, K.J., Rodgers, G.W. and Mander, J.B. (2008), "Novel controllable semiactive-devices for reshaping structural response", Ieee-Asme Transactions on Mechatronics, 13, 647-657. https://doi.org/10.1109/TMECH.2008.2003958
- Chen, Z.H., Ni, Y.Q. and Or, S.W. (2015), "Characterization and modeling of a self-sensing MR damper under harmonic loading", Smart Struct. Syst., 15(4), 1103-1120. https://doi.org/10.12989/sss.2015.15.4.1103
- Chopra, A.K. (1995), Dynamics of structures : Theory and applications to earthquake engineering.
- Dyke, S.J. and Spencer, B.F. (1996), "Modeling and control of magnetorheological dampers for seismic response reduction", Smart Mater. Struct., 5(5), 565-575. https://doi.org/10.1088/0964-1726/5/5/006
- Esteki, K., Bagchi, A. and Sedaghti, R. (2015), "Semi-active control of seismic response of a building using MR fluid-based tuned mass damper", Smart Struct. Syst., 16(5), 807-833. https://doi.org/10.12989/sss.2015.16.5.807
- Ewing, C.M., Guillin, C., Dhakal, R.P. and Chase, J.G. (2009), "Spectral analysis of semi-actively controlled structures subjected to blast loading", Struct. Eng. Mech., 33(1), 79-93. https://doi.org/10.12989/sem.2009.33.1.079
- Feng, M.Q. (1993), "Application of hybrid sliding isolation system to buildings", J. Eng. Mech. - ASCE, 119(10), 2090-2108. https://doi.org/10.1061/(ASCE)0733-9399(1993)119:10(2090)
- Feng, M.Q., Shinozuka, M. and Fujii, S. (1993), "Frictioncontrollable sliding isolation system", J. Eng. Mech. - ASCE, 119, 1845-1864. https://doi.org/10.1061/(ASCE)0733-9399(1993)119:9(1845)
- Huang, Q.D., Gardoni, P. and Hurlebaus, S. (2015), "Assessment of modal parameters considering measurement and modeling errors", Smart Struct. Syst., 15, 717-733. https://doi.org/10.12989/sss.2015.15.3.717
- Jabbari, F. and Bobrow, J.E. (2002), "Vibration suppression with a resetable device", J. Eng. Mech. - ASCE, 128(9), 916-924. https://doi.org/10.1061/(ASCE)0733-9399(2002)128:9(916)
- Jansen, L.M. and Dyke, S.J. (2000), "Semiactive control strategies for MR dampers: Comparative study", J. Eng. Mech. - ASCE, 126(8), 795-803. https://doi.org/10.1061/(ASCE)0733-9399(2000)126:8(795)
- Katebi, J. and Zadeh, S.M. (2016), "Time delay study for semiactive control of coupled adjacent structures using MR damper", Struct. Eng. Mech., 58(6), 1127-1143. https://doi.org/10.12989/sem.2016.58.6.1127
- Kim, Y., Langari, R. and Hurlebaus, S. (2010), "Control of a seismically excited benchmark building using linear matrix inequality-based semiactive nonlinear fuzzy control", J. Struct. Eng. - ASCE, 136(8), 1023-1026. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000192
- Kori, J.G. and Jangid, R.S. (2008), "Semi-active friction dampers for seismic control of structures", Smart Struct. Syst., 4(4), 493-515. https://doi.org/10.12989/sss.2008.4.4.493
- Maiti, D.K., Shyju, P.P. and Vijayaraju, K. (2006), "Vibration control of mechanical systems using semi-active MR-damper", Smart Struct. Syst., 2(1), 61-80. https://doi.org/10.12989/sss.2006.2.1.061
- Makris, N. and Chang, S.P. (2000), "Effect of viscous, viscoplastic and friction damping on the response of seismic isolated structures", Earthq. Eng. Struct. D., 29, 85-107. https://doi.org/10.1002/(SICI)1096-9845(200001)29:1<85::AID-EQE902>3.0.CO;2-N
- Mulligan, K.J. (2007), Experimental and analytical studies of semi-active and passive structural control of buildings, PhD, University of Canterbury.
- Mulligan, K.J., Chase, J.G., Mander, J.B., Rodgers, G.W. and Elliott, R.B. (2010), "Nonlinear models and validation for resetable device design and enhanced force capacity", Struct. Control Health Monit., 17(3), 301-316. https://doi.org/10.1002/stc.298
- Mulligan, K.J., Chase, J.G., Mander, J.B., Rodgers, G.W., Elliott, R.B., Franco-Anaya, R. and Carr, A.J. (2009), "Experimental validation of semi-active resetable actuators in a 1/5th scale test structure", Earthq. Eng. Struct. D., 38, 517-536. https://doi.org/10.1002/eqe.868
- Nagarajaiah, S. and Jung, H. J. (2014), "Smart tuned mass dampers: recent developments", Smart Struct. Syst., 13, 173-176. https://doi.org/10.12989/sss.2014.13.2.173
- Ozbulut, O.E., Bitaraf, M. and Hurlebaus, S. (2011), "Adaptive control of base-isolated structures against near-field earthquakes using variable friction dampers", Eng. Struct., 33(12), 3143-3154. https://doi.org/10.1016/j.engstruct.2011.08.022
- Ozbulut, O.E. and Hurlebaus, S. (2010), "Fuzzy control of piezoelectric friction dampers for seismic protection of smart base isolated buildings", Bull. Earthq. Eng., 8(6), 1435-1455. https://doi.org/10.1007/s10518-010-9187-5
- Ozbulut, O.E. and Hurlebaus, S. (2011a), "Energy-balance assessment of shape memory alloy-based seismic isolation devices", Smart Struct. Syst., 8(4), 399-412. https://doi.org/10.12989/sss.2011.8.4.399
- Ozbulut, O.E. and Hurlebaus, S. (2011b), "Re-centering variable friction device for vibration control of structures subjected to near-field earthquakes", Mech. Syst. Signal Pr., 25(8), 2849-2862. https://doi.org/10.1016/j.ymssp.2011.04.017
- Ozbulut, O.E. and Hurlebaus, S. (2012a), "Application of an SMA-based hybrid control device to 20-story nonlinear benchmark building", Earthq. Eng. Struct. D., 41(13), 1831-1843. https://doi.org/10.1002/eqe.2160
- Ozbulut, O.E. and Hurlebaus, S. (2012b), "A comparative study on the seismic performance of superelastic-friction base isolators against Near-Field Earthquakes", Earthq. Spectra, 28(3), 1147-1163. https://doi.org/10.1193/1.4000070
- Ramallo, J.C., Johnson, E.A. and Spencer, B.F. (2002) " 'Smart' base isolation systems", J. Eng. Mech. - ASCE, 128(10), 1088-1099. https://doi.org/10.1061/(ASCE)0733-9399(2002)128:10(1088)
- Rodgers, G.W., Mander, J.B., Chase, J.G., Mulligan, K.J., Deam, B.L. and Carr, A. (2007), "Re-shaping hysteretic behaviour - spectral analysis and design equations for semi-active structures", Earthq. Eng. Struct. D., 36(1), 77-100. https://doi.org/10.1002/eqe.624
- Som, A., Kim, D.H. and Son, H.S. (2015), "Semiactive magnetorheological damper for high aspect ratio boring process", Ieee-Asme Transactions on Mechatronics, 20(5), 2575-2582. https://doi.org/10.1109/TMECH.2015.2388861
- Sommerville, P., Smith, N., Punyamurthula, S. and Sun, J. (1997), "Development of Ground Motion Time Histories For Phase II Of The FEMA/SAC Steel Project, SAC Background Document Report SAC/BD-97/04.
- Spencer, B.F., Dyke, S.J., Sain, M.K. and Carlson, J. (1997), "Phenomenological model of magnetorheological damper", J. Eng. Mech. - ASCE, 123(3), 230-238. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:3(230)
- Spencer, B.F., Johnson, E.A. and Ramallo, J.C. (2000), " 'Smart' isolation for seismic control", Int. J. Series C-Mech. Syst. Machine Elem. Manufact. - Jsme, 43, 704-711.
- Sun, C., Nagarajaiah, S. and Dick, A.J. (2014), "Family of smart tuned mass dampers with variable frequency under harmonic excitations and ground motions: closed-form evaluation", Smart Struct. Syst., 13(2), 319-341. https://doi.org/10.12989/sss.2014.13.2.319
- Woo, S.S., Lee, S.H. and Chung, L. (2011), "Seismic response control of elastic and inelastic structures by using passive and semi-active tuned mass dampers", Smart Struct. Syst., 8(3), 239-252. https://doi.org/10.12989/sss.2011.8.3.239
- Yang, J.N. and Agrawal, A.K. (2002), "Semi-active hybrid control systems for nonlinear buildings against near-field earthquakes", Eng. Struct., 24(3), 271-280. https://doi.org/10.1016/S0141-0296(01)00094-3
- Yang, J.N., Bobrow, J., Jabbari, F., Leavitt, J., Cheng, C.P. and Lin, P.Y. (2007), "Full-scale experimental verification of resetable semi-active stiffness dampers", Earthq. Eng. Struct. D., 36(9), 1255-1273. https://doi.org/10.1002/eqe.681
- Zhang, J.Q. and Agrawal, A.K. (2015), "An innovative hardware emulated simple passive semi-active controller for vibration control of MR dampers", Smart Struct. Syst., 15(3), 831-846. https://doi.org/10.12989/sss.2015.15.3.831
- Zhou, Z., Meng, S.P., Wu, J. and Zhao, Y. (2012), "Semi-active control on long-span reticulated steel structures using MR dampers under multi-dimensional earthquake excitations", Smart Struct. Syst., 10(6), 557-572. https://doi.org/10.12989/sss.2012.10.6.557