DOI QR코드

DOI QR Code

Analysis of actively-confined concrete columns using prestressed steel tubes

  • 투고 : 2016.09.01
  • 심사 : 2017.01.18
  • 발행 : 2017.05.25

초록

In this paper, an innovative technique for finite element (FE) modeling of steel tube-confined concrete (STCC) columns with active confinement under axial compressive loading is presented. In this method, a new constitutive model for the stress-strain relationship of actively-confined concrete is proposed. In total, 14 series of experimental STCC stub columns having active confinement were modeled using the ABAQUS software. The results obtained from the 3D model including the compressive strength at the initial peak point and failure point, as well as the axial and lateral stress-strain curves were compared with the experimental results to verify the accuracy of the 3D model. It was found that there existed a good agreement between them. A parametric study was conducted to investigate the effect of the concrete compressive strength, steel tube wall thickness, and pre-stressing level on the behavior of STCC columns with active confinement. The results indicated that increasing the concrete core's compressive strength leads to an increase in the compressive strength of the active composite column as well as its earlier failure. Furthermore, a reduction in the tube external diameter-to-wall thickness ratio affects the axial stress-strain curve and the confining pressure, while increasing the pre-stressing level has a negligible effect on the two.

키워드

참고문헌

  1. ABAQUS 6.12 Documentation (2012), ABAQUS Users and Analysis Users Manual, Rhode Island, U.S.A.
  2. Chang, X., Huang, C.K. and Chen, Y.J. (2009), "Mechanical performance of eccentrically loaded prestressing concrete filled circular steel tube columns by means of expansive cement", Eng. Struct., 31(11), 2588-2597. https://doi.org/10.1016/j.engstruct.2009.06.007
  3. Chen, W.F. (1982), Plasticity in Reinforced Concrete.
  4. Ellobody, E., Young, B. and Lam, D. (2006), "Behaviour of normal and high strength concrete-filled compact steel tube circular stub columns", J. Constr. Steel Res., 62(7), 706-715. https://doi.org/10.1016/j.jcsr.2005.11.002
  5. Elsawaf, S. (2012), "Robustness of connections to concrete-filled steel tubular columns under fire during heating and cooling", Ph.D. Dissertation, University of Manchester, Manchester, U.K.
  6. Feeser, L.J. and Chinn, J. (1962), "Strength and stiffness of spirally prestressed concrete cylinders", PCI J., 7(3), 55-62. https://doi.org/10.15554/pcij.06011962.55.62
  7. Gupta, P.K., Verma, V.K., Khaudhair, Z.A. and Singh, H. (2015), "Effect of tube area on the behavior of concrete filled tubular columns", Comput. Concrete, 15(2), 141-166. https://doi.org/10.12989/cac.2015.15.2.141
  8. Haghinejad, A. and Nematzadeh, M. (2016), "Three-dimensional finite element analysis of compressive behavior of circular steel tube-confined concrete stub columns by new confinement relationships", Lat. Am. J. Sol. Struct., 13(5), 916-944. https://doi.org/10.1590/1679-78252631
  9. Han, L.H., Yao, G.H., Chen, Z.B. and Yu, Q. (2005), "Experimental behaviour of steel tube confined concrete (STCC) columns", Steel Compos. Struct., 5(6), 459-484. https://doi.org/10.12989/scs.2005.5.6.459
  10. Hu, H.T. and Schnobrich, W.C. (1989), "Constitutive modeling of concrete by using nonassociated plasticity", J. Mater. Civil Eng., 1(4), 199-216. https://doi.org/10.1061/(ASCE)0899-1561(1989)1:4(199)
  11. Hu, H.T., Huang, C.S., Wu, M.H. and Wu, Y.M. (2003), "Nonlinear analysis of axially loaded concrete-filled tube columns with confinement effect", J. Struct. Eng., 129(10), 1323-1329.
  12. Huang, C.S., Yeh, Y.K., Liu, G.Y., Hu, H.T., Tsai, K.C., Weng, Y.T., Wang, S.H. and Wu, M.H. (2002), "Axial load behavior of stiffened concrete-filled steel columns", J. Struct. Eng., 128(9), 1222-1230. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:9(1222)
  13. Janke, L., Czaderski, C., Ruth, J. and Motavalli, M. (2009), "Experiments on the residual load-bearing capacity of prestressed confined concrete columns", Eng. Struct., 31(10), 2247-2256. https://doi.org/10.1016/j.engstruct.2009.04.006
  14. Johansson, M. and Gylltoft, K. (2002), "Mechanical behavior of circular steel-concrete composite stub columns", J. Struct. Eng., 128(8), 1073-1081. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:8(1073)
  15. Krstulovic-Opara, N. and Thiedeman, P.D. (2000), "Active confinement of concrete members with self-stressing composites", ACI Mater. J., 97(3), 297-308.
  16. Mander, J.B., Priestley, M.J.N. and Park, R. (1988), "Theoretical stress-strain model for confined concrete", J. Struct. Eng., 114(8), 1804-1826. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
  17. Martin, C.W. (1968), "Spirally prestressed concrete cylinders", ACI J., 65(10), 837-845.
  18. Moghaddam, H., Samadi, M. and Pilakoutas, K. (2010), "Compressive behavior of concrete actively confined by metal strips; part B: Analysis", Mater. Struct., 43(10), 1383-1396. https://doi.org/10.1617/s11527-010-9589-5
  19. Moghaddam, H., Samadi, M., Pilakoutas, K. and Mohebbi, S. (2010), "Axial compressive behavior of concrete actively confined by metal strips; part A: Experimental study", Mater. Struct., 43(10), 1369-1381. https://doi.org/10.1617/s11527-010-9588-6
  20. Mokari, J. and Moghadam, A.S. (2008), "Experimental and theoretical study of reinforced concrete columns with poor confinement retrofitted by thermal post tension steel jacketing", J. Appl. Sci., 8(24), 4579-4586. https://doi.org/10.3923/jas.2008.4579.4586
  21. Mortazavi, A.A., Pilakoutas, K. and Son, K.S. (2003), "RC column strengthening by lateral pre-tensioning of FRP", Constr. Build. Mater., 17(6), 491-497. https://doi.org/10.1016/S0950-0618(03)00046-1
  22. Nematzadeh, M. and Naghipour, M. (2012), "Compressive strength and modulus of elasticity of freshly compressed concrete", Constr. Build. Mater., 34, 476-485. https://doi.org/10.1016/j.conbuildmat.2012.02.055
  23. Nematzadeh, M., Fazli, S., Naghipour, M. and Jalali, J. (2017c), "Experimental study on modulus of elasticity of steel tubeconfined concrete stub columns with active and passive confinement", Eng. Struct., 130, 142-153. https://doi.org/10.1016/j.engstruct.2016.10.008
  24. Nematzadeh, M., Hajirasouliha, I., Haghinejad, A. and Naghipour, M. (2017a), "Compressive behaviour of circular steel tubeconfined concrete stub columns with active and passive confinement", Steel Compos. Struct., In press.
  25. Nematzadeh, M., Naghipour, M., Jalali, J. and Salari, A. (2017b), "Experimental study and calculation of confinement relationships for prestressed steel tube-confined compressed concrete stub columns", J. Civil Eng. Manage., In press.
  26. Saenz, L.P. (1964), "Discussion of „equation for the stress-strain curve of concrete' by P. Desayi, and S. Krishnan", J. Am. Concrete Inst., 61, 1229-1235.
  27. Schneider, S.P. (1998), "Axially loaded concrete-filled steel tubes", J. Struct. Eng., 124(10), 1125-1138. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:10(1125)
  28. Shin, M. and Andrawes, B. (2010), "Experimental investigation of actively confined concrete using shape memory alloys", Eng. Struct., 32(3), 656-664. https://doi.org/10.1016/j.engstruct.2009.11.012
  29. Shinohara, Y. (2008), "Effect of transverse prestressing on shear behaviors of high-strength concrete columns", Proceedings of the 14th World Conference on Earthquake Engineering, Beijing, China, October.
  30. Shraideh, M.S. and Aboutaha, R.S. (2013), "Analysis of steel-GFRP reinforced concrete circular columns", Comput. Concrete, 11(4), 351-364. https://doi.org/10.12989/cac.2013.11.4.351
  31. Wang, W., Guo, Z. and Shi, Y. (2011), "Finite element analysis on behavior of the joint with steel tube confined concrete (STCC) column to reinforced concrete beam", Adv. Mater. Res., 243, 527-530.
  32. Yu, Q., Tao, Z., Liu, W. and Chen, Z.B. (2010), "Analysis and calculations of steel tube confined concrete (STCC) stub columns", J. Constr. Steel Res., 66(1), 53-64. https://doi.org/10.1016/j.jcsr.2009.08.003

피인용 문헌

  1. Seismic response of concrete columns with nanofiber reinforced polymer layer vol.20, pp.3, 2017, https://doi.org/10.12989/cac.2017.20.3.361
  2. Evaluation of interfacial shear stress in active steel tube-confined concrete columns vol.20, pp.4, 2017, https://doi.org/10.12989/cac.2017.20.4.469
  3. The effect of active and passive confining pressure on compressive behavior of STCC and CFST vol.9, pp.2, 2017, https://doi.org/10.12989/acc.2020.9.2.161
  4. Effect of axial loading conditions and confinement type on concrete-steel composite behavior vol.25, pp.2, 2017, https://doi.org/10.12989/cac.2020.25.2.095
  5. Analysis-oriented model for seismic assessment of RC jacket retrofitted columns vol.37, pp.3, 2017, https://doi.org/10.12989/scs.2020.37.3.371
  6. Analytical post-heating behavior of concrete-filled steel tubular columns containing tire rubber vol.26, pp.6, 2017, https://doi.org/10.12989/cac.2020.26.6.467
  7. Effect of concrete confinement level on load-bearing capacity of steel-reinforced concrete (SRC) columns under eccentric loading: Experiment and FEA model vol.35, pp.None, 2022, https://doi.org/10.1016/j.istruc.2021.10.094