DOI QR코드

DOI QR Code

A Simple Analytical Model for MEMS Cantilever Beam Piezoelectric Accelerometer and High Sensitivity Design for SHM (structural health monitoring) Applications

  • 투고 : 2016.09.21
  • 심사 : 2016.10.24
  • 발행 : 2017.04.25

초록

Cantilever beam MEMS piezoelectric accelerometers are the simplest and most widely used accelerometer structure. This paper discusses the design of a piezoelectric accelerometer exclusively for SHM applications. While such accelerometers need to operate at a lower frequency range, they also need to possess high sensitivity and low noise floor. The availability of a simple model for deflection, charge, and voltage sensitivities will make the accelerometer design procedure less cumbersome. However, a review of the open literature suggests that such a model has not yet been proposed. In addition, previous works either depended on FEM analysis or only reported on the fabrication and characterization of piezoelectric accelerometers. Hence, this paper presents, for the first time, a simple analytical model developed for the deflection, induced voltage, and charge sensitivity of a cantilever beam piezoelectric accelerometer.The model is then verified using FEM analysis for a range of different cases. Further, the model was validated by comparing the induced voltages of an accelerometer estimated using this model with experimental voltages measured in the accelerometer after fabrication. Subsequently, the design of an accelerometer is demonstrated for SHM applications using the analytical model developed in this work. The designed accelerometer has 60 mV/g voltage sensitivity and 2.4 pC/g charge sensitivity, which are relatively high values compared to those of the piezoresistive and capacitive accelerometers for SHM applications reported earlier.

키워드

과제정보

연구 과제 주관 기관 : National Program on Micro and Smart Systems (NPMaSS)

참고문헌

  1. A. Sabato, M. Q. Feng, Y. Fukuda, D. L. Carni, and G. Fortino, IEEE Sensors Journal, 16, 2942 (2016). [DOI: http://citeweb.info/20160246898] https://doi.org/10.1109/JSEN.2016.2522940
  2. Z. Herrasti, I. Val, I. Gabilondo, J. Berganzo, A. Arriola, and F. Martínez, Sensor. Actuat. A, 247, 604 (2016). [DOI: http://dx.doi.org/10.1016/j.sna.2016.06.027]
  3. J. P. Lynch, A. Partridge, and K. H. Law, J. Aero. Eng., 16, 108 (2003). [DOI: http://dx.doi.org/10.1061/(ASCE)0893-1321(2003)16:3(108)]
  4. E. Guzman, J. Cugnoni, and T. Gmur, Smart Mater. Struct., 24, 055017 (2015). [DOI: http://dx.doi.org/10.1088/0964-1726/24/5/055017]
  5. Z. Shen, C. Y. Tan, K. Yao, L. Zhang, and Y. F. Chen, Sensor. Actuat. A, 241, 113 (2016). [DOI: http://dx.doi.org/10.1016/j.sna.2016.02.022]
  6. M. Giammarini, D. Isidori, M. Pieralisi, C. Cristalli, M. Fioravanti, and E. Concettoni, Microsys. Technol., 22, 1845, (2016). [DOI: http://dx.doi.org/10.1007/s00542-016-2859-6]
  7. R. Reus, J. Micromech. Microeng., 9, 123 (1999). [DOI : http://dx.doi.org/10.1088/0960-1317/9/2/005]
  8. A. Iula and N. Lamberti, IEEE/ASME transactions on mechatronics, 4, 207 (1999). [DOI: http://dx.doi.org/10.1109/3516.769547]
  9. M. J. Vellekooi, C.C.G. Visser, P. M. Sarro, and A. Venema, Sensor. Actuat., A21, 1027 (1990). [DOI: http://dx.doi.org/10.1016/0924-4247(90)87083-u]
  10. T. Xu, G. Wu, G. Zhang, and Y. Hao, Sensor. Actuat. A, 104, 61 (2003). [DOI: http://dx.doi.org/10.1016/S0924-4247(02)00484-3]
  11. L. P. Wang, R. A. Wolf J r., and Y. Wang, Journal of microelectromechanical systems, 12, 433 (2003). [DOI: http://dx.doi.org/10.1109/JMEMS.2003.811749]
  12. Y. Nemirosky, A. Nemirovsky, P. Maralt, and N. Setter, Sensor. Actuat., A56, 239 (1996). [DOI: http://dx.doi.org/10.1016/S0924-4247(96)01324-6]
  13. Y. R. Wong, Y. Yuan, H. Du, and X. Xia, Sensor. Actuat. A, 229, 23 (2015). [DOI: http://dx.doi.org/10.1016/j.sna.2015.03.012]
  14. T. Kobayashi, H. Okada, T. Masuda, R. Maeda, and T. Itoh, Smart Mater. Struct., 20, 065017 (2011). [DOI: http://dx.doi.org/10.1088/0964-1726/20/6/065017]
  15. S. Kavitha, R. J. Daniel, and K. Sumangala, Measurement, 46, 3372 (2013). [DOI : h t tp://dx.doi.org/10.1016/j.measurement.2013.05.013]
  16. S. Kavitha, R. J. Daniel, and K. Sumangala, Sensors & Transducers Journal, 144, 62 (2012).
  17. S. Kavitha, R. J. Daniel, and K. Sumangala, Mehanical Systems and Signal Processing, 66, 410 (2016). [DOI: http://dx.doi.org/10.1016/j.ymssp.2015.06.005]
  18. J. Y. Wang, T. T. Wang, and H. Guo, Key Engineering Materials, 645, 841 (2015). [DOI. 10.4028/www.scientific.net/KEM.645-646.841]
  19. C. C. Lee, G. Z. Cao, and I. Y. Shen, Sensor. Actuat. A, 159, 88 (2010). [DOI: http://dx.doi.org/10.1016/j.sna.2010.02.022]
  20. P. Muralt, IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 47, 903 (2000). [DOI: http://dx.doi.org/10.1109/58.852073]
  21. K. Kunz, P. Enoksson, and G. Stemme, Sensor. Actuat. A, 92, 156 (2001). [DOI: http://dx.doi.org/10.1016/S0924-4247(01)00555-6]
  22. Ph. Luginbuhl, G. A. Racine, Ph. Lerch, and B. Romanowicz, Sensor. Actuat. A, 54, 530 (1996). [DOI: http://dx.doi.org/10.1109/ISAF.1994.522419]
  23. M. Sobocinski, M. Leinonen, J. Juuti, N. Mantyniemi, and H. Jantunen, Sensor. Actuat. A, 216, 370 (2014). [DOI: http://dx.doi.org/10.1016/j.sna.2014.06.017]
  24. S. P. Beeby, N. J. Grabham, and N. M. White, Sensor. Actuat. A, 92, 168 (2001). [DOI: http://dx.doi.org/10.1016/S0924-4247(01)00559-3]
  25. Q. Q. Zhang, S. J. Gross, and S. Tadigadapa, Sensor. Actuat. A, 105, 91 (2003). [DOI:10.1016/S0924-4247(03)00068-2]
  26. H. G. Yu, L. Zou, and K. Deng, Sensor. Actuat. A, 107, 26 (2003). [DOI: http://dx.doi.org/10.1016/S0924-4247(03)00271-1]
  27. J. Xie, M. Hu, S. F. Ling, and H. Du, Sensor. Actuat. A, 126, 182 (2006). [DOI: http://dx.doi.org/10.1016/j.sna.2005.09.019]
  28. D. L. DeVoe, Journal of Microelectromechanical Systems, 10, 180 (2001). [DOI: http://dx.doi.org/10.1109/84.925733]
  29. C. T. Pan, Z. H. Liu, Y. C. Chen, and C. F. Liu, Sensor. Actuat. A, 159, 96 (2010). [DOI: http://dx.doi.org/10.1016/j.sna.2010.02.023]
  30. Y. R. Wong, Y. Yuan, H. Du, and X. Xia, Sensor. Actuat. A, 229, 23 (2015). [DOI: http://dx.doi.org/10.1016/j.sna.2015.03.012. 0924-4247]
  31. K. Kim, S. Zhang, G. Salazar, and X. Jiang, Sensor. Actuat. A, 178, 40 (2012). [DOI: http://dx.doi.org/10.1016/j.sna.2012.02.003]
  32. R. Schulze, M. Heinrich, and P. Nossol, Sensor. Actuat. A, 208, 159 (2014). [DOI: http://dx.doi.org/10.1016/j.sna.2013.12.032.]
  33. J. Ryu, J. J. Choi, B. D. Hahn, W. H. Yoon, B. K. Lee, J. H. Choi, and D. S. Park, Mater. Sci. Eng. R, 170, 67 (2010). [DOI: http://dx.doi.org/10.1016/j.mseb.2010.02.028]
  34. X. Gao, W. H. Shih, and W. Y. Shih, Smart Mater. Struct., 18, 125018 (2009). [DOI: http://dx.doi.org/10.1088/0964-1726/18/12/125018]
  35. A. T. Kollias and J. N. Avaritsiotis, Sensor. Actuat. A, 121, 434 (2005). [DOI: http://dx.doi.org/10.1016/j.sna.2005.03.014]
  36. W. Zhou, A. Khaliq, Y. Tang, H. Ji, and R. R. Selmic, Sensor. Actuat. A, 125, 69 (2005). [DOI: http://dx.doi.org/10.1016/j.sna.2005.07.009]
  37. A. T. Mineto, M.P.S. Braun, H. A. Navarro, and P. S. Varoto, Proc. 9th Brazilian conference on Dynamics, Control and their Applications (Serra Negra, Brazil, 2010).
  38. http://www.comsol.com
  39. T. H. Sung, J. C. Huang, J. H. Hsu, S. R. Jian, and T. G. Nieh, Appl. Phys. Lett., 100, 211903 (2012). [DOI: http://dx.doi.org/10.1063/1.4720169]

피인용 문헌

  1. A fuzzy α-cut optimization analysis for vibration control of laminated composite smart structures under uncertainties vol.54, 2018, https://doi.org/10.1016/j.apm.2017.10.002
  2. Design of Data Acquisition System for Silicon Micro Machined Resonant Accelerometer vol.470, pp.1757-899X, 2019, https://doi.org/10.1088/1757-899X/470/1/012044