References
- Alizadeh, E. and Dehestani, M. (2015), "Analysis of composite girders with hybrid GFRP hat-shape sections and concrete slab", Struct. Eng. Mech., 54(6), 1135-1152. https://doi.org/10.12989/sem.2015.54.6.1135
- Aydin, F. and Saribiyik, M. (2013), "Investigation of flexural behaviors of hybrid beams formed with GFRP box section and concrete", Constr. Build. Mater., 41, 563-569. https://doi.org/10.1016/j.conbuildmat.2012.12.060
- Bakis, C., Bank, L. C., Brown, V., Cosenza, E., Davalos, J. F., Lesko, J. J., ... and Triantafillou, T. C. (2002), "Fiber-reinforced polymer composites for construction-state-of-the-art review", J. Compos. Construct., 6(2), 73-87. https://doi.org/10.1061/(ASCE)1090-0268(2002)6:2(73)
- De Sutter, S., Remy, O., Tysmans, T. and Wastiels, J. (2014), "Development and experimental validation of a lightweight stay-in-place composite formwork for concrete beams", Constr. Build. Mater., 63, 33-39. https://doi.org/10.1016/j.conbuildmat.2014.03.032
- Deskovic, N., Triantafillou, T. C. and Meier, U. (1995), "Innovative design of FRP combined with concrete: short-term behavior", J. Struct. Eng., 121(7), 1069-1078. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:7(1069)
- Fam, A. and Honickman, H. (2010), "Built-up hybrid composite box girders fabricated and tested in flexure", Eng. Struct., 32(4), 1028-1037. https://doi.org/10.1016/j.engstruct.2009.12.029
- Fam, A., Schnerch, D. and Rizkalla, S. (2005), "Rectangular filament-wound glass fiber reinforced polymer tubes filled with concrete under flexural and axial loading: experimental investigation", J. Compos. Construct., 9(1), 25-33. https://doi.org/10.1061/(ASCE)1090-0268(2005)9:1(25)
- Fardis, M.N. and Khalili, H. (1981), "Concrete encased in fiberglass-reinforced plastic", J. Am. Concrete Inst., 78(6), 440-446.
- Hibbitt, D., Karlsson, B. and Sorensen, P. (2004), ABAQUS Analysis User's Manual, Pawtucket, USA.
- Ji, H.S., Byun, J.K., Lee, C.S., Son, B.J. and Ma, Z.J. (2011), "Structural performance of composite sandwich bridge decks with hybrid GFRP-steel core", Compos. Struct., 93(2), 430-442. https://doi.org/10.1016/j.compstruct.2010.08.037
- Keller, T., Schaumann, E. and Vallee, T. (2006), "Hybrid FRP-concrete sandwich bridge deck", Proceedings of the 3rd International Conference on FRP Composites in Civil Engineering (CICE 2006), Miami, USA.
- Kim, H.Y., Hwang, Y.K., Park, K.T., Lee, Y.H. and Kim, S.M. (2005), "Fiber reinforced plastic deck profile for I-girder bridges", Compos. Struct., 67(4), 411-416. https://doi.org/10.1016/j.compstruct.2004.01.020
- Kim, Y.J. and Fam, A. (2011), "Numerical analysis of pultruded GFRP box girders supporting adhesively-bonded concrete deck in flexure", Eng. Struct., 33(12), 3527-3536. https://doi.org/10.1016/j.engstruct.2011.07.016
- Kim, Y.J. and Yoon, D.K. (2009), "Identifying critical sources of bridge deterioration in cold regions through the constructed bridges in North Dakota", J. Bridge Eng., 15(5), 542-552. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000087
- Kitane, Y., Aref, A.J. and Lee, G.C. (2004), "Static and fatigue testing of hybrid fiber-reinforced polymer-concrete bridge superstructure", J. Compos. Construct., 8(2), 182-190. https://doi.org/10.1061/(ASCE)1090-0268(2004)8:2(182)
- Teng, J.G., Yu, T., Wong, Y.L. and Dong, S.L. (2007), "Hybrid FRP-concrete-steel tubular columns: concept and behavior", Constr. Build. Mater., 21(4), 846-854. https://doi.org/10.1016/j.conbuildmat.2006.06.017
Cited by
- Partial sectional confinement in a quasi-encased steel-concrete composite beam vol.22, pp.3, 2018, https://doi.org/10.12989/cac.2018.22.3.269
- Structural performance of GFRP-concrete composite beams vol.68, pp.4, 2017, https://doi.org/10.12989/sem.2018.68.4.485