초록
In order to reduce the weight of the blow motor case and to maintain the strength of the motor joint, the mechanical joining strength is to be predicted. The true stress - true strain curves for finite element analysis were obtained through tensile tests of HGI and DP 780 steel. The mechanical joining strength was predicted through an explicit finite element analysis and the accuracy of the predicted results was verified by actual sample test. The regression equation for predicting the mechanical joining strength to the thickness of the DP 780 steel was derived. The minimum thickness of DP 780(1.2mm), which is equivalent to the joining strength of HGI(2.6mm), was derived from the equation.