DOI QR코드

DOI QR Code

Research trend analysis for Combustion products, Combustion products remove technique

연소생성물제거 기술에 대한 연구 동향 분석

  • Lee, Hyunjin (Dept. of Chemical Engineering, Kwangwoon University) ;
  • Ko, Jae-Wook (Dept. of Chemical Engineering, Kwangwoon University)
  • Received : 2016.06.30
  • Accepted : 2017.02.15
  • Published : 2017.02.28

Abstract

According to 2015 ministry of public safety and security statistics, product of combustion makes the most victims while fire. for that reason, recent studies about combustion products have been researched actively in domestic and foreign papers. In domestic, study is handling the combustion product effects on human body and flame propagation. Foreign study is conduct about combustion product effects to shelter in offshore and toxic effects on human. because combustion product is toxic and disturb escape by block the view, many research conducted about optimize combustion product removal facilities using dispersion experiments and CFD simulations. In this study, this paper analysed research trend about toxic gas production model while combustion and its removal facilities, it will be the standard of combustion products research.

2015 국민안전처 통계에 따르면, 화재 피해 중 연소생성물에 의한 피해가 가장 많은 사상자를 내는 것으로 나타났다. 이러한 이유로 최근 연소생성물에 관한 연구는 국내외에서 활발하게 이루어지고 있다. 국내에서는 연소 생성물이 사람에게 미치는 영향과, 화염의 전파속도에 미치는 영향이라는 관점에서 연구가 진행되고 있고, 해외에서는 연소생성물이 사람에게 미치는 독성 뿐만 아니라 offshore 대피소에 미치는 영향까지 연구되고 있다. 연소생성물은 독성을 가지고 있고, 시야를 가려 탈출을 방해하기 때문에 많은 연구에서 실험과 CFD시뮬레이션을 이용하여 연소 생성물 제거 설비의 최적화에 관한 연구를 진행하고 있다. 본 연구에서는 연소를 통한 독성가스 발생 모델과, 그 가스의 제거 시설에 대한 연구 동향을 분석하여, 추후 연소생성물 연구의 기준이 될 것으로 판단된다.

Keywords

References

  1. Hae-Pyeong Lee, "Combustion Engineering", Hawsumok, (2015)
  2. Yong-Ju Yeo, "Smoke Management Engneering", KOREA FIRE SAFETY LABORATORY, (2010)
  3. Ministry of Public Safety and Security, National Fire Data System
  4. CSB, CARIBBEAN PETROLEUM TANK TERMINAL EXPLOSION AND MULTIPLE TANK FIRES, (2015)
  5. Kyu-Hyung Oh, "Principles of Fire Behavior", Donghwapub
  6. Yong-Ju Yeo "The Analysis on the Effect of Supply Air Velocities by Location of Supply Air Damper on the Performance Efficiency of the Smoke Exhaust Systems", Journal of fire & flammability, 24(6), (2010)
  7. KIST, "A Study on the Hazard of Flue Gas in Flame Retardant", (2000)
  8. Natioanl Fire Service Academy, "Study on fire mechanism", (2005)
  9. Young-Ju Park, Hae-Pyeong Lee, "A Study on Application of Combustion Products for Foresst Fire Investigation", Journal of th KOSOS, 26(4), (2011)
  10. OGP, "Risk Assessment Data Directory", (2010)
  11. Yeon Jun Bae, "A Study on Preventing Spread of Smoke and Securing Safety of Evacuation in Central Core Type High-Rise Building", Major in Fire & Disaster Protection Engineering Graduate School of Environment & Design Gachon University
  12. Kim, Beom-Kyu, "The Effect of Outside Wind Conditions on the Mechanical Ventilation Performance and the Exhaust Smoke Control in High-rise Building Fires", Department of Fire Protection & Disaster Prevention Engineering The Graduate School of Hoseo University
  13. Tae-Hoon, Kim, "A Study on the Effective Smoke Control Method of Large-volume Space comparted by Smoke Reservoir Screen", Department of Fire & Disaster Prevention Graduate School of Industry &Science, Kangwon National University
  14. NFPA 92A, Standard for Smoke- Control System Utilizing Barriers and Pressure Differences, (2009)
  15. NFPA 204, Standard for Smoke and Heat Venting, (2007)
  16. NFPA 101, Life Safety code, (2000)
  17. NFPA 92, Standard for Smoke Control System, (2012)
  18. BS(British Standard) 5588, (1998)
  19. NFPA 92A, Recommended Practice for Smoke Control System, (2012)
  20. Ryu, Sung Ho, "A study on Characteristics of Air Egress Velocity in vestibule Pressurization System for Preventing Smoke Backflow", Dept. of Energy Safety Engineering Grauate School of Energy and Environmet Seoul National University of Science & Technology
  21. Korea Institute of Construction Technology, "Underground space Improvement and diaster prevention technology research project", (2006)
  22. Il-Young, Kim, "A Study on the Improvement of Ventilation performance Using the Smoke Control Duct", Major in U-City, dept. of U-City IT convergence and Urban Policy in Graduate School of Hansei University
  23. Byoung-man, Park, "A study on relevant standards analysis for improving the performance of smoke control system", Major in Fire and Disaster Protection Engineering Graduate School of Environment Kyungwon University
  24. Do-yeon Son, "A Study on the Optimization of Construction and Maintenance od Smoke Control System", University of Seoul
  25. Jae-hyun Park, "A Study on Development of Aerodynamic Design and Test Method for Satisfactory Performance of Smoke Control Damper - For a Performance -Based Design of Smoke Control System-", University of Seoul
  26. Kyungjun Park, Kijun Lee, Bettar El Hadi, Jaihyo Lee, Dongil Shin, "Smoke Control According to the Ventilation Capacity in Subway Tunnel Fire", Journal of The Korean Institute for Gas, 15(3), (2011)
  27. Yun Suk Sonh, Seung Kyu Dan, Bong Woo Lee, Seong Pil Kwon, Dongil Shin, Tae Ok Kim, Simulation of Heat and Smoke Behavior for Wood and Subway Fires by Fire Dynamics Simulator, Journal of The Korean Institute for Gas, 14(6), (2010)