DOI QR코드

DOI QR Code

드레스룸의 결로발생 환경 및 저감방안에 관한 연구

A Study on the Condensation Occurrence Environment and Method of Reducing Condensation in Dress Room

  • 투고 : 2016.10.28
  • 심사 : 2017.02.13
  • 발행 : 2017.03.30

초록

According to living style in Korea changes, having a dress room in an apartment house become more common these days. In Korea, the dress room is often located next to the bathroom, which occurs highest risk of humidity increase and condensation. However, the design requirements for the reducing condensation risk at the dress room have been considering as the same standard as other living spaces, which makes the dress room space difficult to prevent condensation. The purpose of the study is to analyze the condensation occurrence environment of the dress room and to evaluate the methods of reducing the condensation risk. According to result of this study, diminishing condensation of dress room with applying insulation or heating method was inappropriate due to excessive design. Controversy, ventilation, and dehumidification method were successful for reducing condensation risk. In addition, it was found to be particularly efficient to close the bathroom door and ventilate the bathroom for a certain period of time.

키워드

과제정보

연구 과제 주관 기관 : 국토교통부

참고문헌

  1. Ministry of Land, Infrastructure and Transport. (2016). Design standard of conservation of building energy No. 2016-944.
  2. Ministry of Land, Infrastructure and Transport. (2016). Design standards for apartment housing to prevent condensation No. 2016-835.
  3. Ministry of Land, Infrastructure and Transport. (2016). Rules on design standard of building mechanical No. 2015-219.
  4. SejinPlan. (2009). Apartments encyclopedia. Seoul: Author
  5. ASHRAE. (2013). ASHRAE Handbook Fundamentals
  6. EnergyPlus. (1996-2015). Engineering Reference
  7. TOTO. (2015). Barrier-free book. Japan: Author
  8. Kim, J.Y., Hwang, H.J., Kim, G.T., Ryu, C.S., & Kim, K.S. (2014). A study on the prevention of condensation in household of apartment buildings, Land & Housing Institute
  9. Cho, S.W., Lee, S.Y., Moon, C.S., & Oh, S.G. (2008). A Study on Demanders' Consciousness by Master Room Planning Types in Apartment House. JOURNAL OF THE KOREAN HOUSING
  10. Babiak, J., Olesen, B. W., & Petras, D. (2009). Low temperature heating and high temperature cooling. Rehva.
  11. Kim, J.H., & Seo, H. (2011). A Study on the Optimum Size of Master Bedroom Walk-In Closet in Apartments. Journal of the Korean Institute of Interior Design, 20(5), 152-159.
  12. Riffat, S. B. (1989). A study of heat and mass transfer through a doorway in a traditionally built house, ASHRAE Trans 95.2, 584-589.
  13. Development of Building Technology to Improve the Living Performance Closely Related with Lifestyle to Realize the Housing Welfare - Development of Preventing Condensation Technology to Satisfy 90 percent of the Living Environment Condition, (2015), WINC-FREE4
  14. Korea Land & Housing Corporation. (2015). Explaining material of dress room and built-in wardrobe condensation
  15. Korea Energy Agency. (2012). Energy efficiency system of dehumidifier. Retrieved 10 January 2016, from http://bpms.energy.or.kr/efficiency_system/product/pd0020.aspx
  16. Related Rentals, (n.d.). Retrieved 1 October 2016, from http://www.relatedrentals.com/apartment-rentals/new-york-city/chelsea/abington-house
  17. Ichikawa, (n.d.). Retrieved 6 September 2016, from http://sumai.tokyu-land.co.jp/branz/ichikawa/plan/
  18. Goduck, (n.d.). Retrieved 1 August 2015, from http://raemian.co.kr/sales/sub/goduck/?menuSeq=7266
  19. Kamikitazawa, (n.d.). Retrieved 6 September 2016, from https://www.proud-web.jp/mansion/kamikitazawa/plan/
  20. Sendagi, (n.d.). Retrieved 6 September 2016, from https://www.proud-web.jp/mansion/sendagi/plan/
  21. Greenwalk3, (n.d.). Retrieved 9 January 2017, http://www.songdoifez.com/new/?mid=mm&act=viewDanjiBestContent&num=96&sec=3
  22. Soul forest, (n.d.). Retrieved 9 January 2017, http://asclepina.wixsite.com/02-2294-5114/about3