DOI QR코드

DOI QR Code

Numerical study on the rotation capacity of CFRP strengthened cold formed steel beams

  • Serror, Mohammed H. (Department of Structural Engineering, Faculty of Engineering, Cairo University) ;
  • Soliman, Essam G. (Department of Structural Engineering, Faculty of Engineering, Cairo University) ;
  • Hassan, Ahmed F. (Department of Structural Engineering, Faculty of Engineering, Cairo University)
  • Received : 2016.10.24
  • Accepted : 2017.01.15
  • Published : 2017.03.20

Abstract

Currently, CFRP (Carbon Fiber Reinforced Polymer) plate bonding is used quite extensively as a strengthening method. In this technique, a composite CFRP plate or sheet of relatively small thickness is bonded with an adhesion material to steel or concrete structure in order to improve its structural behavior and strength. The sheets or plates do not require much space and give a composite action between the adherents. In this study, the rotation capacity of CFRP-strengthened cold-formed steel (CFS) beams has been evaluated through numerical investigation. Studies on different structural levels have been performed. At the beam level, C-section has been adopted with different values of profile thickness, web height, and flange width. At the connection level, a web bolted moment resistant type of connection using through plate has been adopted. In web-bolted connections without CFRP strengthening, premature web buckling results in early loss of strength. Hence, CFRP sheets and plates with different mechanical properties and geometric configurations have been examined to delay web and flange buckling and to produce relatively high moment strength and rotation capacity. The numerical results reveal that CFRP strengthening may increase strength, initial stiffness, and rotation capacity when compared with the case without strengthening.

Keywords

References

  1. AISI S110 (2007), Standard for Seismic Design of Cold-Formed Steel Structural Systems - Special Bolted Moment Frames; American Iron and Steel Institute, Washington, D.C., USA.
  2. ANSI/AISC 360-10 (2010), Specification for Structural Steel Buildings; American Institute of Steel Construction, IL, USA.
  3. ANSI/AISC 341-10 (2010), Seismic Provisions for Structural Steel Buildings; American Institute of Steel Construction, IL, USA.
  4. ANSYS release 11.0, Swanson analysis system (1998), Houston, TX, USA.
  5. Bagheri, S.A., Petkovski, M., Pilakoutas, K. and Mirghaderi, R. (2012), "Development of cold-formed steel elements for earthquake resistant moment frame buildings", Thin-Wall. Struct., 53, 99-108. https://doi.org/10.1016/j.tws.2012.01.004
  6. Calderoni, B., De Martino, A., Formisano, A. and Fiorino, L. (2009), "Cold formed steel beams under monotonic and cyclic loading: Experimental investigation", J. Constr. Steel Res., 65(1), 219-227. https://doi.org/10.1016/j.jcsr.2008.07.014
  7. Casafont, M., Arnedo, A., Roure, F. and Rodriguez-Ferran, A. (2006a), "Experimental testing of joints for seismic design of lightweight structures. Part 1. Screwed joints in straps", Thin-Wall. Struct., 44(2), 197-210. https://doi.org/10.1016/j.tws.2006.01.002
  8. Casafont, M., Arnedo, A., Roure, F. and Rodriguez-Ferran, A. (2006b), "Experimental testing of joints for seismic design of lightweight structures. Part 2: Bolted joints in straps", Thin-Wall. Struct., 44(6), 677-691. https://doi.org/10.1016/j.tws.2006.04.006
  9. Casafont, M., Arnedo, A., Roure, F. and Rodriguez-Ferran, A. (2007), "Experimental testing of joints for seismic design of lightweight structures. Part 3: Gussets, corner joints, x-braced frames", Thin-Wall. Struct., 45(7), 637-659. https://doi.org/10.1016/j.tws.2007.05.008
  10. Dar, M.A., Yusuf, M., Dar, A.R. and Raju, J. (2015), "Experimental study on innovative sections for cold formed steel beams", Steel Compos. Struct., Int. J., 19(6), 1599-1610. https://doi.org/10.12989/scs.2015.19.6.1599
  11. Dinis, P.B. and Camotim, D. (2015), "Cold-formed steel columns undergoing local-distortional coupling: Behaviour and direct strength prediction against interactive failure", Comput. Struct., 147, 181-208. https://doi.org/10.1016/j.compstruc.2014.09.012
  12. Dubina, D. (2008), "Behavior and performance of cold-formed steel-framed houses under seismic action", J. Constr. Steel Res., 64(7), 896-913. https://doi.org/10.1016/j.jcsr.2008.01.029
  13. ECP-205 (ASD) (2011), Egyptian Code of Practice for Steel Construction and Bridges; Housing and Research Center, Giza, Egypt.
  14. El-Tawil, S., Ekin, E., Subhash, G. and Chao, S.H. (2011), "Retraining local and global buckling behavior of steel plastic hinges using CFRP", J. Constr. Steel Res., 67(3), 261-269. https://doi.org/10.1016/j.jcsr.2010.11.007
  15. Essam, G.S., Serror, M.H. and Ahmed, F.H. (2016), "Numerical study on the behavior of CFRP-strengthened cold-formed steel beams", M.Sc. Thesis; Department of Structural Engineering, Faculty of Engineering, Cairo University, Egypt.
  16. Eurocode 3 (2005), Design of steel structures: Part 1.1: General rules and rules for buildings, EN 1993-1-1.
  17. Faris, A.U. and Mehtab, A. (2013), "Mechanical properties of steel-CFRP composite specimen under uniaxial tension", Steel Compos. Struct., Int. J., 15(6), 659-677. https://doi.org/10.12989/scs.2013.15.6.659
  18. Gholami, M., Mohd Sam, A.R., Marsono, A.K., Tahir, M.M. and Faridmehr, I. (2016), "Performance of steel beams strengthened with pultruded CFRP plate under various exposures", Steel Compos. Struct., Int. J., 20(5), 999-1022. https://doi.org/10.12989/scs.2016.20.5.999
  19. Gunaydin, M., Adanur, S., Altunisik, A.C. and Sevim, B. (2015), "Static and dynamic responses of Halgavor Footbridge using steel and FRP materials", Steel Compos. Struct., Int. J., 18(1), 51-69. https://doi.org/10.12989/scs.2015.18.1.051
  20. Harries, K.A., Andrew, J.P. and Elizabeth, J.A. (2009), "Enhancing stability of structural steel sections using FRP", Thin-Wall. Struct., 47(10), 1092-1101. https://doi.org/10.1016/j.tws.2008.10.007
  21. Hassan, E.M., Serror, M.H. and Mourad, S.A. (2017), "Numerical predition of available rotation capacity of cold-formed steel beams", J. Constr. Steel Res., 128, 84-98. https://doi.org/10.1016/j.jcsr.2016.08.010
  22. Islam, S.M.Z. and Young, B. (2014), "FRP strenghtning of lean duplex satinless steel hollow sections subjected to web crippling", Thin-Wall. Struct., 85, 183-200. https://doi.org/10.1016/j.tws.2014.08.010
  23. Lawson, R.M. (1992), "New developments in use of cold formed steel in buildings", Constr. Build. Mater., 6(4), 201-204. https://doi.org/10.1016/0950-0618(92)90038-Z
  24. Lim, J.B.P. and Nethercot, D. (2003), "Ultimate strength of bolted moment-connections between cold-formed steel members", Thin-Wall. Struct., 41(11), 1019-1039. https://doi.org/10.1016/S0263-8231(03)00045-4
  25. Linghoff, D., Haghani, R. and Al-Emrani, M. (2009), "Carbonfiber compoites for strengthening steel structures", Thin-Wall. Struct., 47(10), 1048-1058. https://doi.org/10.1016/j.tws.2008.10.019
  26. Moghimi, H. and Ronagh, H. (2009), "Performance of light-gauge cold-formed steel strap- braced stud walls subjected to cyclic loading", Eng. Struct., 31(1), 69-83. https://doi.org/10.1016/j.engstruct.2008.07.016
  27. Padilla-Llano, D.A., Eatherton, M.R. and Moen, C.D. (2016), "Cyclic flexural response and energy dissipation of cold-formed steel framing members", Thin-Wall. Struct., 98B, 518-532.
  28. Park, J.W. and Yoo, J.H. (2015), "Flexural and compression behavior for steel structures strengthened with Carbon Fiber Reinforced Polymers (CFRPs) sheet", Steel Compos. Struct., Int. J., 19(2), 441-465. https://doi.org/10.12989/scs.2015.19.2.441
  29. Phan, D.T., Lim, J.B.P., Tanyimboh, T.T. and Sha, W. (2013), "An efficient genetic algorithm for the design optimization of coldformed steel portal frame buildings", Steel Compos. Struct., Int. J., 15(5), 519-538. https://doi.org/10.12989/scs.2013.15.5.519
  30. Sato, A. and Uang, C-M. (2009), "Seismic design procedure development for cold-formed steel-special bolted moment frames", J. Constr. Steel Res., 65(4), 860-868. https://doi.org/10.1016/j.jcsr.2008.03.016
  31. Sato, A. and Uang, C-M. (2010), "Seismic performance factors for cold-formed steel special bolted moment frames", J. Struct. Eng., 36(8), 961-967.
  32. Sayed-Ahmed, E.Y. (2004), "Stregnthening of thin-walled steel I-section beams using CFRP strips", Proceedings of the 4th International Conference on Advanced Composite Materials in Bridges and Structures, Calgary, Alberta, Canada, July.
  33. Serror, M.H., Hassan, E.M. and Mourad, S.A. (2016), "Experimental study on the rotation capacity of cold-formed steel beams", J. Constr. Steel Res., 121, 216-228. https://doi.org/10.1016/j.jcsr.2016.02.005
  34. SIKA (2016), URL: http://usa.sika.com/en/repair-protection/02a002/02a013/02a013sa06.html
  35. Silvestre, N., Young, B. and Dinar, C. (2008), "Non-linear behavior and load-carrying capacity of CFRP-strengthened lipped channel steel columns", Eng. Struct., 30(10), 2613-2630. https://doi.org/10.1016/j.engstruct.2008.02.010
  36. Uang, C-M., Sato, A., Hong, J-K. and Wood, K. (2010), "Cyclic testing and modeling of cold-formed steel special bolted moment frame connections", J. Struct. Eng., 136(8), 953-960. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000190
  37. Wong, M.F. and Chung, K.F. (2002), "Structural behavior of bolted moment connections in cold-formed steel beam-column sub-frames", J. Constr. Steel Res., 58(2), 253-274. https://doi.org/10.1016/S0143-974X(01)00044-X
  38. Yang, N., Zhong, Y., Meng, Q. and Zhang, H. (2014), "Hysteretic behaviors of cold-formed steel beam-columns with hollow rectangular section: Experimental and numerical simulations", Thin-Wall. Struct., 80, 217-230. https://doi.org/10.1016/j.tws.2014.03.004
  39. Yu, C. and Schafer, B.W. (2007), "Simulation of cold-formed steel beams in local and distortional buckling with applications to the direct strength method", J. Constr. Steel Res., 63(5), 581-590. https://doi.org/10.1016/j.jcsr.2006.07.008
  40. Yu, W.K., Chung, K.F. and Wong, M.F. (2005), "Analysis of bolted moment connections in cold- formed steel beam-column sub-frames", J. Constr. Steel Res., 61(9), 1332-1352. https://doi.org/10.1016/j.jcsr.2005.03.001
  41. Zhao, X.L. and Zhang, L. (2007) "State-of-the-art review on FRP strengthened steel structures", Eng. Struct., 29(8), 1808-1823. https://doi.org/10.1016/j.engstruct.2006.10.006
  42. Zhao, X.L. and Al-Mahaidi, R. (2009), "Web buckling of lightsteel beams strengthened with CFRP subjected to end-bearing forces", Thin-Wall. Struct., 47(10), 1029-1036. https://doi.org/10.1016/j.tws.2008.10.009

Cited by

  1. Stress intensity factors for double-edged cracked steel beams strengthened with CFRP plates vol.33, pp.5, 2017, https://doi.org/10.12989/scs.2019.33.5.629
  2. Behavior of CFS built-up battened columns: Parametric study and design recommendations vol.74, pp.3, 2017, https://doi.org/10.12989/sem.2020.74.3.381
  3. Numerical Investigation of Composite Behavior and Strength of Rectangular Concrete-Filled Cold-Formed Steel Tubular Stub Columns vol.14, pp.20, 2017, https://doi.org/10.3390/ma14206221