Development of Large Volume of Highly Viscoelastic Drug Infuser

대용량 고점탄성 약물 주입기 개발

  • Bang, Jun Ho (Department of Materials Science and Engineering, Korea University) ;
  • Kwon, Soonwoo (Hugel) ;
  • Kang, Taewon (Division of Advanced Mechanical Engineering Mechanical & Biomedical Engineering, Kangwon National University)
  • Received : 2016.09.27
  • Accepted : 2017.01.23
  • Published : 2017.02.15

Abstract

A drug infuser is a well-known device that is widely used in various areas of clinical practice. However, some materials used in the drug infuser have been developed for particular purposes and thus, their design characteristics have to be changed considerably. Especially, the implications of a new filler in the drug infuser have migrated to the areas of body corrections in plastic surgery. In this study, the design process of a drug infuser managing a large content volume has been studied from the perspective of structure safety. A new design of the drug infuser that uses a 10 cc filler with high viscosity is presented. Finite element analysis is used to confirm that the assembled drug infuser is safe enough to hold the required loading of 490 N. Furthermore, the final prototype of the drug infuser was successful in reducing the weight up to 400 g without compromising the safety.

Keywords

References

  1. Kim, H.. Y., Kim, H. J., 2010, Numerical Analysis and Optimum Design of Disposable Drug Infuser Using Fluid-Structure Interaction Technique, The Korean Society of Mechanical Engineers, 34:11 1595-1602. https://doi.org/10.3795/KSME-A.2010.34.11.1595
  2. Skokal, W. A., 1997, Infusion Pump Update, RN 60, 35-38.
  3. Shin, Y. K., Han, N. G., Tak, T. O., 2013, Dynamic Analysis of Driving Mechanism for Displacement Controlled Automatic Drug Injector, The Korean Society of Mechanical Engineers -A, 37:3 303-311. https://doi.org/10.3795/KSME-A.2013.37.3.303
  4. Nam, S. B., Chang, C. H., Rhee, H. D., Lee, Y. W., 2002, Clinical Application of Gas Forming Infusion Pump for Intravenous Postoperative Pain Control, The Korean Pain Society, 16:02 190-197.
  5. Dorr, R. T., Trinca, C. E., Griffith, K., Dombrowsky, P. L., Salmon, S. E., 1979, Limitations of a Portable Infusion Pump in Ambulatory Patients Receiving Continuous Infusions of Anticancer Drugs, Cancer Treat Rep, 63:2 211-213.
  6. Kwom, S. W., 2015, R&D Final Report of Development of Large Volume Drug Infuser, Korea Industrial Complex Corporation
  7. TEOSYALPEN, n.d., viewed 17 October 2014,
  8. MCURE, n.d., viewed 17 October 2014,
  9. MOOHAN, n.d., viewed 17 October 2014,
  10. USA MESO, n.d., viewed 17 October 2014,
  11. DERMOTHERAP, n.d., viewed 17 October 2014,