Interrupting characteristics of the transformer superconducting fault current limiter

  • Hwang, S.H. (Chosun University) ;
  • Choi, H.W. (Chosun University) ;
  • Jeong, I.S. (Chosun University) ;
  • Choi, H.S. (Chosun University)
  • Received : 2017.11.22
  • Accepted : 2017.12.29
  • Published : 2017.12.31

Abstract

This paper analyzed the fault current limiting characteristics of the previously proposed transformer superconducting fault current limiter (TSFCL) interruption system according to its transformer type. The TSFCL interruption system is an interruption technology that combines a TSFCL, which uses a transformer and a superconductor, and a mechanical DC circuit breaker. This technology first limits the fault current using the inductance of the transformer winding and the quench characteristics of the superconductor. The limited fault current is then interrupted by a mechanical DC circuit breaker. The magnitude of the limited fault current can be controlled by the quench resistance of the superconductor in the TSFCL and the turns ratio of the transformer. When the fault current is controlled using a superconductor, additional costs are incurred due to the cooling vessel and the length of the superconductor. When the fault current is controlled using step-up and step-down transformers, however, it is possible to control the fault current more economically than using the superconductor. The TSFCL interruption system was designed using PSCAD/EMTDC-based analysis software, and the fault current limiting characteristics according to the type of the transformer were analyzed. The turns ratios of the step-up and step-down transformers were set to 1:2 and 2:1. The results were compared with those of a transformer with a 1:1 turns ratio.

Keywords

References

  1. Shreya lyer, W. G. Dunford, and Martin Ordonez, "DC distribution systems for homes," Power & Energy Society General Meeting, 2015 IEEE, Accession Number: 15538193, Oct. 2015.
  2. Zheng Ganhao, "Study on DC Circuit Breaker," Intelligent Systems Design and Engineering Applications (ISDEA), 2014 Fifth International Conference on, Accession Number: 14817916, pp. 942-945, Dec. 2014.
  3. H. J. Lee, "Effect of a SFCL on commutation failure in a HVDC system," IEEE Transactions on Applied Superconductivity, vol. 23, p. 5600104-5600104, 2012.
  4. Feng Zheng, Changhong Deng, Lei Chen, Shichun Li, Yang Liu, and Yuxiang Liao, "Transient Performance Improvement of Microgrid by a Resistive Superconducting Fault Current Limiter," IEEE Transactions on Applied Superconductivity, vol. 25, p.5602305, 2015.
  5. B. Pauli, G. Mauthe, E. Ruoss, G. Ecklin, J. Porter, and J. Vithayathil, "Development of a high current HVDC circuit breaker with fast fault clearing capability," IEEE Transactions on Power Delivery, vol. 3, pp. 2072-2080, 1988. https://doi.org/10.1109/61.194019
  6. P. H. Schavemaker and L. van der Slui, "An improved Mayr-type arc model based on current-zero measurements [circuit breakers]," IEEE Transactions on Power Delivery, vol. 15, pp. 580-584, 2000. https://doi.org/10.1109/61.852988
  7. H. Nakao, Y. Nakagoshi, M. Hatano, T. Koshizuka, S. Nishiwaki, A. Kobayashi, T. Murao, and S. Yanabu, "DC current interruption in HVDC $SF_{6}$ gas MRTB by means of self-excited oscillation superimposition," IEEE Transactions on Power Delivery, vol. 16, pp. 687-693, 2001. https://doi.org/10.1109/61.956757

Cited by

  1. Further study of a novel inductive SFCL for multiterminal HVDC systems vol.34, pp.11, 2017, https://doi.org/10.1088/1361-6668/ac2555