DOI QR코드

DOI QR Code

Performance evaluation of a 400 W precise window motor for glass houses

  • Hong, Soon-Joong (Rural Human Resource Development Center, Rural Development Administration) ;
  • Park, Soo-Bok (Chung-Oh Engineering Co., Ltd) ;
  • Kang, Na-Rae (Department of Biosystems Machinery Engineering, Chungnam National University) ;
  • Kim, Yong-Joo (Department of Biosystems Machinery Engineering, Chungnam National University) ;
  • Chung, Sun-Ok (Department of Biosystems Machinery Engineering, Chungnam National University)
  • Received : 2017.08.17
  • Accepted : 2017.11.29
  • Published : 2017.12.31

Abstract

Crop growth and production cost are greatly influenced by management of environmental factors such as ambient temperature, humidity, and $CO_2$, especially in protected horticulture. Opening and closing of greenhouses is the most important operation for control of these ambient environmental factors, and precise and stable operation requires high performance window motors. In this study, a 400 W precise window motor was constructed, and its performance was evaluated for plastic and glass greenhouses. First, the motor was designed and fabricated by benchmarking of an advanced foreign product. Then, the performance was evaluated through vibration, PCB (Process Control Block), and load tests. Vibration tests resulted in averaged vibration displacement and velocity of the developed motor of 0.002 mm and 0.2267m/s, which were statistically significantly different from those of the target motor. Average vibration acceleration ($0.26m/s^2$) of the developed motor was also significantly different from that ($0.51m/s^2$) of the target motor. PCB tests showed 2 - 4 mm deviation from the target values, and confirmed the operating status and precision of the control. Load tests with a 300 kg load also showed acceptable operating status and durability. Current values were $1.31{\pm}0.06A$ and RPMs were in the range of 2.9 - 3.0. Considering the above results, the developed window motor would be competitive to the target foreign product.

Keywords

References

  1. Ahonen T, Virrankoski R, Elmusrati M. 2008. Greenhouse monitoring with wireless sensor network. In Proceeding of the 4th International Conference on Mechatronic and Embedded Systems and Applications (MESA) pp. 403-408.
  2. Candido A, Cicirelli F, Furfaro A, Nigro L. 2007. Embedded real-time system for climate control in a complex greenhouse. International Agrophysics 21:17-27.
  3. Chinmaya K, Mohanty AR. 2006. Multistage gearbox condition monitoring using motor current signature analysis and Kolmogorov-Smirnov test. Journal of Sound and Vibration 290:337-368. https://doi.org/10.1016/j.jsv.2005.04.020
  4. Jang JH, Chung SO, Choi CH, Park YJ, Chun WK, Kim SI, Kwon OW, Kim CW, Hong SJ, Kim YJ. 2016. Effects of PTO gear face width on safety factors. Korean Journal of Agricultural Science 43:650-655.
  5. Kim BR, Chae SH. 2016. Policy Directions for Controlled Horticulture Industry. pp. 26. Publishing KREI (Korea Rural Economic Institute). Republic of Korea. [in Korean]
  6. Lee PU, Chung SO, Chou CH, Park YJ, Kim YJ. 2016. Analysis of the effects of operating point of tractor engine on fatigue life of PTO gear using simulation. Korean Journal of Agricultural Science 43:441-449. https://doi.org/10.7744/kjoas.20160047
  7. Lee KC. 2004. Forecasting Future Technology, Drawing Road Maps, and Developing Effective Investment Techniques in Agriculture. pp. 58. Publishing MAFRA (Ministry of Agriculture, Food and Rural Affairs). Republic of Korea. [in Korean]
  8. Miguel AF, Silva AM. 2000. Porous materials to control climate behaviour of enclosures: an application to the study of screened greenhouses. Energy and Buildings 31:195-209. https://doi.org/10.1016/S0378-7788(99)00010-9
  9. Munoz P, Montero JI, Anton A, Guiffrida F. 1999. Effect of insect-proof screens and roof openings on greenhouse ventilation. Journal of Agricultural Engineering Research 73:171-178. https://doi.org/10.1006/jaer.1998.0404
  10. Nandi S, Toliyat HA, Li X, Nigro L. 2005. Condition monitoring and fault diagnosis of electrical motors-A Review. Transactions on Energy Conversion 20:719-729. https://doi.org/10.1109/TEC.2005.847955
  11. Park NG, Kim TJ, Hwang SM. 2000. Analysis of vibration for permanent magnet motors considering mechanical and magnetic coupling effects. Transactions on Magnetics 36:1346-1350. https://doi.org/10.1109/20.877688
  12. Seo DS, Kang CY. 2015. Development Strategies for Material Industries of Greenhouses in Korea. pp. 2-3. Publishing Korea Rural Economic Institute. Republic of Korea.
  13. Suh WM, Bae YH, Heo HJ, Kwak CS, Lee SG, L JW, Yoon YC. 2009. Analyses of heating and cooling load in greenhouse of protected horticulture complex in Taean. Journal of the Korean Society of Agricultural Engineers 51:45-52. [in Korean]
  14. Teitel M. 2007. The effect of screened openings on greenhouse microclimate. Agricultural and Forest Meteorology 143:159-175. https://doi.org/10.1016/j.agrformet.2007.01.005
  15. Teitel M, Ziskind G, Liran O, Dubovsky V, Letan R. 2008. Effect of wind direction on greenhouse ventilation rate, airflow patterns and temperature distributions. Biosystems Engineering 101:351-369. https://doi.org/10.1016/j.biosystemseng.2008.09.004
  16. Xu M, Marangoni RD. 1994. Vibration analysis of a motor-flexible coupling-rotor system subject to misalignment and unbalance, part I: theoretical model and analysis. Journal of Sound and Vibration 176:663-679. https://doi.org/10.1006/jsvi.1994.1405
  17. Yun SW, Choi MK, Shin YS, Yu C, Yoon YC. 2013. Estimation of design load for analyzing behavior of greenhouse foundation in Korea. Proceedings of the KSAM & KSBEC 2013 Spring Conference 18:263-364. [in Korean]

Cited by

  1. Determination of safety factor for agricultural gear reducer using simulation software vol.45, pp.2, 2017, https://doi.org/10.7744/kjoas.20170064
  2. Performance Evaluation of a Suspension-Type Dehumidifier with a Heating Module for Smart Greenhouses vol.45, pp.3, 2017, https://doi.org/10.1007/s42853-020-00055-w