DOI QR코드

DOI QR Code

Comparative Analysis of Peak Impact Acceleration and Impact Shock Frequency Components According to the Type of Treadmill for Treadmill-running

  • Lee, Jae Seok (Department of Physical Education, Kyung Hee University) ;
  • Hur, Seung Eun (Department of Sports Outdoor, Eulji University) ;
  • Park, Seong Han (Department of Physical Education, Kyung Nam University) ;
  • Moon, Hwang Woon (Department of Sports Outdoor, Eulji University) ;
  • Koo, Bon Ho (Department of Physical Education, Kyung Hee University)
  • Received : 2017.09.04
  • Accepted : 2017.09.29
  • Published : 2017.12.31

Abstract

Objective: The purpose of this study was to show differences in impact variables between treadmills with (treadmills B, C, and D) and treadmills without a shock-absorbing function (treadmill A) to propose the development of a treadmill with improved or added shock-absorbing function to reduce impact shock. Method: Thirteen male students in their twenties who had habitual rear foot strike during running ran on four treadmills at 2.67 m/sec while ankle and neck acceleration data were collected. The magnitude of the ankle and neck acceleration peaks and peak positive ankle acceleration were calculated. The power spectral density of each signal was calculated to transform the ankle and neck accelerations in the frequency domain. Results: The peak positive ankle acceleration on treadmill B was significantly lesser than that on treadmills A and D, and that on treadmill C was significantly less than that on treadmill A (p < .01). Peak positive neck acceleration was not statistically different between the treadmills. The frequencies of the peak power of the ankle and neck acceleration signal within the lower and higher frequency ranges were not statistically different between the treadmills. The signal power magnitude of the ankle in higher frequency ranges on treadmill B was significantly less than that on treadmills A, C, and D (p < .01). The signal power magnitude of the ankle in higher frequency ranges was not statistically different between the treadmills. The signal power magnitudes of the neck acceleration signal within the lower and higher frequency ranges were not statistically significantly different between the treadmills. Conclusion: Our results indicate that the shock-absorbing function of a treadmill plays a role in reducing impact shock. Therefore, in future treadmill development, shock-absorbing function should be improved or incorporated to reduce impact shock to the body.

Keywords

References

  1. Bobbert, M. F., Schamhardt, H. C. & Nigg, B. M. (1991). Calculation of vertical ground reaction force estimates during running from positional data. Journal of Biomechanics, 24(12), 1095-1105. https://doi.org/10.1016/0021-9290(91)90002-5
  2. Boo, J. H. & Lee, D. C. (2005). The Effect of Impact Acceleration with Hardness and Thickness of Footwear Midsole on Treadmill. Journal of the Korean Institute of Plant Engineering, 10(3), 13-25.
  3. Derrick, T. R., Hamill, J. & Caldwell, G. E. (1998). Energy absorption of impacts during running at various stride lengths. Medicine and Science in Sports and Exercise, 30(1), 128-135. doi:10.1097/00005768-199801000-00018
  4. Dufek, J. S. & Bates, B. T. (1990). The evaluation and prediction of impact forces during landings. Medicine and Science in Sports and Exercise, 22(3), 370-377.
  5. Edwards, W. B., Derrick, T. R. & Hamill, J. (2012). Musculoskeletal attenuation of impact shock in response to knee angle manipulation. Journal of Applied Biomechanics, 28(5), 502-510. https://doi.org/10.1123/jab.28.5.502
  6. Gruber, A. H., Boyer, K. A., Derrick, T. R. & Hamill, J. (2014). Impact shock frequency components and attenuation in rearfoot and forefoot running. Journal of Sport and Health Science, 3(2), 113-121. doi: https://doi.org/10.1016/j.jshs.2014.03.004
  7. Hamill, J., Derrick, T. R. & Holt, K. G. (1995). Shock attenuation and stride frequency during running. Human Movement Science, 14(1), 45-60. doi:https://doi.org/10.1016/0167-9457(95)00004-C
  8. Hennig, E. M. & Lafortune, M. A. (1991). Relationships between ground reaction force and tibial bone acceleration parameters. International Journal of Sport Biomechanics, 7(3), 303-309. https://doi.org/10.1123/ijsb.7.3.303
  9. Hreljac, A., Marshall, R. N. & Hume, P. A. (2000). Evaluation of lower extremity overuse injury potential in runners. Medicine and Science in Sports and Exercise, 32(9), 1635-1641.
  10. Ko, E. H., Choi, H. S., Kim, T. H., Roh, J. S. & Lee, K. S. (2004). Effect of the Fatigue to Insole Types during Treadmill Exercise. Physical Therapy Korea, 11, 17-25.
  11. Kwak, C.-S., Mok, S.-H. & Kwon, O.-B. (2005). The Influence of Midsole Hardness and Sole Thickness of Sport Shoes on Ball Flex Angle with the Increment of Running Velocity. Korean Journal of Sport Biomechanics, 15(4), 153-168. https://doi.org/10.5103/KJSB.2005.15.4.153
  12. Lafortune, M. A., Lake, M. J. & Hennig, E. M. (1996). Differential shock transmission response of the human body to impact severity and lower limb posture. Journal of Biomechanics, 29(12), 1531-1537. doi: http://dx.doi.org/10.1016/S0021-9290(96)80004-2
  13. Lee, K. K. (2004). In-shoe Loads during Treadmill Running. Korean Journal of Sport Biomechanics, 14(2), 105-119. https://doi.org/10.5103/KJSB.2004.14.2.105
  14. Milner, C. E., Ferber, R., Pollard, C. D., Hamill, J. & Davis, I. S. (2006). Biomechanical factors associated with tibial stress fracture in female runners. Medicine and Science in Sports and Exercise, 38(2), 323. https://doi.org/10.1249/01.mss.0000183477.75808.92
  15. Oh, Y. J. & Lee, C. M. (2009). The Study on 3‐Axes Acceleration Impact of Lower Limbs Joint during Gait. Journal of the Ergonomics Society of Korea, 28(3), 33-39. https://doi.org/10.5143/JESK.2009.28.3.033
  16. Ryu, J. S. (2005). Impact shock and kinematic characteristics of the Lower extremity's joint during downhill running. Korean Journal of Sport Biomechanics, 15(4), 117-129. https://doi.org/10.5103/KJSB.2005.15.4.117
  17. Ryu, J. S. & Lim, G. Y. (2015). Impact Shock Components and Attenuation in Flat Foot Running. Korean Journal of Sport Biomechanics, 25(3), 284-292.
  18. Shorten, M. R. & Winslow, D. S. (1992). Spectral analysis of impact shock during running. International Journal of Sport Biomechanics, 8(4), 288-304. https://doi.org/10.1123/ijsb.8.4.288
  19. Yoon, N. S., Yi, K. O., Kim, J. Y., Mun, M. S., & Yang, G. T. (2000). Comparison Analysis of the Angle Vriation Patterns and DRM on Treadmill Walking by Slope. Korean Journal of Physical Education, 39(1), 569-579.
  20. Zifchock, R. A., Davis, I. & Hamill, J. (2006). Kinetic asymmetry in female runners with and without retrospective tibial stress fractures. Journal of Biomechanics, 39(15), 2792-2797. https://doi.org/10.1016/j.jbiomech.2005.10.003