DOI QR코드

DOI QR Code

A Study on the Structural Performance of the Building Exterior Panel Using the Moving Clips

이동 클립을 이용한 건축물 외장재의 구조적 성능에 관한 연구

  • 곽의신 (한국기술교육대학교 창의융합공학협동과정) ;
  • 기창군 ((주)덕인금속) ;
  • 이상호 (부산대학교 건축공학과) ;
  • 손수덕 (한국기술교육대학교 디자인.건축공학부) ;
  • 이승재 (한국기술교육대학교 디자인.건축공학부)
  • Received : 2017.08.22
  • Accepted : 2017.10.13
  • Published : 2017.12.26

Abstract

A recent global trend in the increase of earthquake-related disasters has become so frequent as to cause various damages to a wide range of mid- to high-rise buildings. Particularly, more attention is being paid to the effect of horizontal load in high-rise buildings not only on the key structural elements of the structures, but also on the possibility of the secondary damages to them due to the failure of exterior panels, which are non-structural elements, but such damages are difficult to cope with as they may be caused by unexpected changes. The present study examined exterior panels using moving clips to prevent such secondary damages on the non-structural elements and analyzed the structural performance of these exterior panels through the finite element analysis and the shaking table test. The analysis results showed that the exterior panels using moving clips satisfied the structural performance against the allowable story drift of KBC2009 and the safety of the exterior panels was verified by the shake table test.

Keywords

Acknowledgement

Supported by : 한국기술교육대학교, 국토교통부

References

  1. Chang, K. K., & Park, N. W. (2014). Development and Performance Evaluation of Under Cut Anchor Stone Curtain Wall Construction Method, Journal of the Korea Institute for Structural Maintenance and Inspection, 18(4), 138-146. https://doi.org/10.11112/JKSMI.2014.18.4.138
  2. Cho, K. P., Hong, S. I., & Kim, W. S. (2006). Wind-resistant design of high-rise apartment building glasses, Journal of Architectural Institute of Korea, 22(1), 77-85.
  3. Cho, K. P., & Hong, S. I. (2006). Wind damages of claddings of high-rise apartment building under strong wind, Journal of Architectural Institute of Korea, 22(2), 43-50.
  4. Cho, Y. W. (2008). A Study on the Development of Structural Performance Evaluation Process/Manual for a Super High-Rise Building Curtain Wall System from the Construction, Manager's Perspective, Seoul National University of Technology.
  5. Ham, H. J., & Kim, Y. S. (2004). Cladding system failure by strong wind and its mitigation method, Journal of Architectural Institute of Korea, 48(7), 51-55.
  6. Jeon, E. K., & Kim, H. J. (2010). A Study on Structural Design of Aluminum Curtain Walls Focused on Mullions and Transoms, Journal of the Regional Association of Architectural Institute of Korea, 2010(1), 285-289.
  7. Kim, K. S. (1991). Wind Load on Tall Building, Journal of Architectural Institute of Korea, 35(1), 29-32.
  8. Kim, Y. S. (1996). A study on following capacity for metal panel curtain wall subjected to the horizontal displacement, Master's thesis, Soong-Sil University, Korea.
  9. Korea Meteorological Administration, Earthquake URL: http://www.kma.go.kr/weather/earthquake_volcano/report.jsp
  10. Kwak, E. S., Jeong, G. M., Ki, C. G., Lee, S. H., & Lee, S. J. (2016). The Study on Structural Performance Review of Displacement Absorbing Performance Improvement Exterior Panel Utilizing Moving Clips, Korea Institute for Structural Maintenance and Inspection Spring Annual Conference, 20(1), 269-270.
  11. Lee, D. W., Kwak, E. S., Shon S. D., & Lee, S. J. (2016). A Study on Horizontal Displacement Following Ability of Welded and Non-welded Building Hardware, Journal of Korean Association for Spatial Structures, 16(4), 75-82. https://doi.org/10.9712/KASS.2016.16.4.075
  12. Lee, K. S. (2014). A development of seismic rehabilitation method of building strengthened with X-bracing using carbon fiber composite cable, Journal of the Korea Institute for Structural Maintenance and Inspection, 18(3), 1-9. https://doi.org/10.11112/JKSMI.2014.18.3.001
  13. Lee, S. I. (2003). Manual to manufacturing process for curtain wall, Journal of Architectural Institute of Korea, 47(9), 44-50.
  14. Lee, Y. W., Yeun, K. W., & Kim, J. (2010). Analysis of wind load on curtain wall member of the building, Proceeding of Architectural Institute of Korea - Autumn 2010, 37-38.
  15. Lee, Y. O. (2011). A Study on the Economical Structual Design Method of Aluminum Curtain Wall System: Focusing on Mullion, Seoul National University of science and Technology.
  16. Min, S. H., Jang, Y. J., Sa, J. C., Lee, J. M., Yun, J. E., Kim, M. S., & Kim, Y. H. (2012). A Survey about Installation Trend for Exterior in Domestic, Korean Institute of Fire Science & Engineering Sping Annual Conference, 11-14.
  17. Shim, H. B., Kim, D. W., Keon, H. S., & Lee, J. H. (2013). Application of wind tunnel test for the exterior and serviceability enhancement of Jeju city hotel, Journal of Architectural Institute of Korea, 57(1), 86-90.
  18. Yim, H. C., Youn, K. J., Kim, J. H., & Park, J. H. (2010). Structural Performance Evaluation of Steel-Aluminum Unit Curtain-Walls for Super Tall Buildings, Journal of Architectural Institute of Korea, 30(1), 109-110.