Evaluation of membrane fouling characteristics due to manganese and chemical cleaning efficiency in microfiltration membrane process

막여과 정수처리공정에서 망간에 의한 막오염 특성 및 화학세정효율 평가

  • Kang, Joon-Seok (Department of Environmental Engineering and Energy, Myongji University) ;
  • Park, Seogyeong (Department of Environmental Engineering and Energy, Myongji University) ;
  • Song, Jiyoung (Department of Environmental Engineering and Energy, Myongji University) ;
  • Jeong, Ahyoung (Department of Environmental Engineering and Energy, Myongji University) ;
  • Lee, Jeong-Jun (Department of Environmental Engineering and Energy, Myongji University) ;
  • Kim, Han-Seung (Department of Environmental Engineering and Energy, Myongji University)
  • 강준석 (명지대학교 환경에너지공학과) ;
  • 박서경 (명지대학교 환경에너지공학과) ;
  • 송지영 (명지대학교 환경에너지공학과) ;
  • 정아영 (명지대학교 환경에너지공학과) ;
  • 이정준 (명지대학교 환경에너지공학과) ;
  • 김한승 (명지대학교 환경에너지공학과)
  • Received : 2017.11.07
  • Accepted : 2017.11.28
  • Published : 2017.12.15

Abstract

In water treatment process using microfiltration membranes, manganese is a substance that causes inorganic membrane fouling. As a result of analysis on the operation data taken from I WTP(Water Treatment Plant), it was confirmed that the increase of TMP was very severe during the period of manganese inflow. The membrane fouling fastened the increase of TMP and shortened the service time of filtration or the cleaning cycle. The TMP of the membrane increased to the maximum of $2.13kgf/cm^2$, but it was recovered to the initial level ($0.17kgf/cm^2$) by the 1st acid cleaning step. It was obvious that the main membrane fouling contaminants are due to inorganic substances. As a result of the analysis on the chemical waste, the concentrations of aluminum(146-164 mg/L) and manganese(110-126 mg/L) were very high. It is considered that aluminum was due to the residual unreacted during coagulation step as a pretreatment process. And manganese is thought to be due to the adsorption on the membrane surface as an adsorbate in feed water component during filtration step. For the efficient maintenance of the membrane filtration facilities, optimization of chemical concentration and CIP conditions is very important when finding the abnormal level of influent including foulants such as manganese.

Keywords

References

  1. Al-Malack, M.H., Anderson, G.K. (1996). Formation of dynamic membranes with crossflow microfiltratioin, J. Membr. Sci., 112, 287-296. https://doi.org/10.1016/0376-7388(95)00303-7
  2. Chang, Y. J., Choo, K.H., Benjamin, M.M., Reiber, S. (1998). Combined adsorption/UF process increases TOC removal, J. AWWA, 90 (5), 90-102.
  3. Choo, K. H., Lee, H. B., Choi, S. J. (2005). Iron and manganese removal and membrane fouling during UF in conjunction with perchlorination for drinking water treatment, J. Membr. Sci, 267, 18-26. https://doi.org/10.1016/j.memsci.2005.05.021
  4. Jung, S. W., Lee, J. P., Kim, H. S. (2001). Removal of Manganese by Oxidation and Filtration in Water Treatment, J. KSEE, 23(4), 661-669.
  5. Kim, C. H., Lee, B. G., Kim, S. S., Park, S. H. (2006). "Investigation of manganese fouling in MF Process", Proceeding of Korean Society of Water Quality, 15-16 November, 2006, Daegu, Korea
  6. Kimura, K., Hane, Y., Watanabe, Y, Amy, G., Ohkuma, N.(2004). Irreversible membrane fouling during ultrafiltration of surface water, Water Rea., 38, 3431-3441. https://doi.org/10.1016/j.watres.2004.05.007
  7. Kwak, H. E. and Park, J. W., Min, S. J., Lim, J. W., Kim, K. H., Park, Y. M., Park, P. K.(2016). Combined Oxidation Coupled with Membrane Filtration for Effective Manganese Removal in Water Treatment, KSWQ, Vol.2016, 121-122.
  8. Lee, B. H. and Kim, J. G., Lee, K. H. (2000). Membrane Fouling by Iron and Manganese in Hollow-fiber Microfiltration, J. KSCE, 7, 591-597.
  9. Lee, E. S. (2006). Reduction Membrane Fouling by Iron and Manganaese, Masters's Thesis, Sungkyunkwan University, Suwon, Korea
  10. Lee, K.W., Choo, K.H., Choi, S.J., Yamamoto, K. (2002). Development of an integrated iron oxide adsorption/membrane separation system for water treatment. Water Sci. Technol. Water Sup., 2, 293-300. https://doi.org/10.2166/ws.2002.0182
  11. Lee, S. H. and Kweon, J. H., Choi, Y. H., Ahn, K. H.(2004). Effects of characterisitics of Flocculent Aggregates on Membrane Fouling in Microfiltration with Coagulation Pretreatment, J. KSWW, 18(6), 785-793.
  12. Ministry of Environment (2014). The study for applicability evaluation and the developmental direction of membrane water treatment facilities.
  13. Oh, I. T. (2007). Evaluation of UF Membrane Fouling Characteristics for Iron and Manganese in Bank-filtered Water. Master's Thesis, Chungbuk University, Cheongju, Korea
  14. Raffaele, M., Pietro A., Leonardo R.(2001). Studies on interactions between membranes(RO and NF) and pollutants (SiO2, NO3-, Mn2+ and humic acid) in water",Desalination 138, 271-281. https://doi.org/10.1016/S0011-9164(01)00273-9
  15. Raveendran, R., Ashworth, B., and Chatelier, B. (2001). "Manganese Removal in Drinking Water Systems", Proceedings of 64th Annual Water Industry Engineers and Operators' Conference, 92-100

Cited by

  1. Multiple injection of permanganate and hypochlorite for manganese removal by oxidation combined with membrane filtration vol.32, pp.3, 2018, https://doi.org/10.11001/jksww.2018.32.3.211
  2. 호소수 탁도변화 대응을 위한 고플럭스 막여과공정의 Pilot 연구 vol.34, pp.6, 2017, https://doi.org/10.11001/jksww.2020.34.6.393
  3. Applicability of a Combined DAF-MF Process to Respond to Changes in Reservoir Water Quality through a Two-Year Pilot Plant Operation vol.11, pp.12, 2017, https://doi.org/10.3390/membranes11120964