DOI QR코드

DOI QR Code

Seismic Response Evaluation of High-Rise Buildings Considering Installation Story of the Mid-Story Isolation System

중간층 면진시스템 설치 위치에 따른 고층건물의 지진응답 분석

  • 김가영 (영남대학교 일반대학원 건축학과) ;
  • 이영락 (영남대학교 일반대학원 건축학과) ;
  • 김현수 (선문대학교 건축사회환경학부) ;
  • 강주원 (영남대학교 건축학부)
  • Received : 2017.10.16
  • Accepted : 2017.11.01
  • Published : 2017.12.15

Abstract

Base isolation system is generally used for low-rise buildings. For high-rise buildings subjected to earthquake loads, a mid-story isolation system was proposed and applied to practical engineering. In this study, seismic responses of high-rise buildings considering the installation story of the mid-story isolation system were evaluated. To do this, the 20-story and 30-story building were used as example structures. Historical earthquakes such as Kobe (1995), Northridge (1994) and Loma Prieta (1989) earthquakes were employed applied as earthquake excitations. The installation location of the mid-story isolation system was changed from the bottom of the $1^{st}$ floor to the bottom of the top floor. The seismic responses of the example building were investigated by changing the location of the isolation layer. Based on the analytical results, when the seismic isolation system is applied, story drift ratio and acceleration response are reduced compared to the case without the isolation system. When the isolation layer is located on the lower part of the building, it is most effective. However, in that case, the possibility that the structure is unstable increases. Therefore, an engineer should consider both structural efficiency and safety when a mid-story isolation system for a high-rise building is designed.

Keywords

References

  1. Hur, M.W., "Seismic Isolation Effects by the Isolation Period of the Vertically Story-added Remodeling Building", Proceeding of Spring Annual Conference of the Korea Concrete Institute, Vol. 29, No. 1, 2017, pp.705-706
  2. Tsuneki, Y., "Middle-Story Isolated Structural System of High-Rise Building", Proceeding of The 14th World Conference on Earthquake Engineering, 2008
  3. Kawamura, S. and Sugisaki, R., "Seismic isolation retrofit in Japan", 12WCEE 2000, 2000, pp.25-33
  4. Hur, M.W., "Construction of Isolation Device for DONG-IL High-Vill New City", Review of Architecture and Building Science, Vol. 54, No. 5, 2010, pp.81-86
  5. Lee, J.Y., "Application of Base Isolation System on The Middle Story of High-Rise Building", Proceeding of Autumn Annual Conference of the Architectural Institute of Korea Structure & Construction, Vol. 28, No. 1, 2008, pp.9-12

Cited by

  1. Seismic Response Evaluation of Mid-Story Isolation System According to the Change of Characteristics of the Seismic Isolation Device vol.18, pp.1, 2018, https://doi.org/10.9712/KASS.2018.18.1.109