DOI QR코드

DOI QR Code

Mechanical features of cable-supported ribbed beam composite slab structure

  • Qiao, W.T. (School of Civil Engineering, Shi Jiazhuang Tiedao University) ;
  • Wang, D. (TRC Engineers, Inc) ;
  • Zhao, M.S. (School of Civil and Environmental Engineering, Nanyang Technological University)
  • Received : 2017.05.23
  • Accepted : 2017.08.10
  • Published : 2017.12.10

Abstract

Cable-supported ribbed beam composite slab structure (CBS) is proposed in this study. As a new cable-supported structure, it has many merits such as long span availability and cost-saving. Inspired by the previous research on cable-supported structures, the fabrication and construction process are developed. Pre-stress design method based on static equilibrium analysis is presented. In the algorithm, the iteration convergence can be accelerated and the calculation result can be kept in an acceptable precision by setting a rational threshold value. The accuracy of this method is also verified by experimental study on a 1:5 scaled model. Further, important parameters affecting the mechanical features of the CBS are discussed. The results indicate that the increases of sag-span ratio, depth of the ribbed beam and cable diameter can improve the mechanical behavior of the CBS by some extent, but the influence of strut sections on mechanical behavior of the CBS is negligible.

Keywords

Acknowledgement

Supported by : National Natural Science Foundation of China, Natural Science Foundation of Hebei Province

References

  1. Abeysinghe, C.M., Thambiratnam, D.P. and Perera, N.J. (2013), "Dynamic performance characteristics of an innovative hybrid composite floor plate system under human-induced loads", Compos. Struct., 96(4), 590-600. https://doi.org/10.1016/j.compstruct.2012.09.015
  2. Chen, Z.H. and Qiao, W.T. (2010), "Analysis on cable supported concrete roof structure and its basic characteristics", Build. Struct., 40(11), 22-25.
  3. Chen, Z.H., Qiao, W.T. and Yan, X.Y. (2010), "Cable supported barrel vault structure system and research on mechanics characteristics", J. Adv. Steel Constr., 6(3), 867-878.
  4. GB5009-2012 (2012), Load Code for the Design of Building Structures, China Building Industry Press; Beijing, China.
  5. Kawaguchi, M., Abe, M. and Hatato, T. et al. (1993). "On a Structure System "Suspen-dome"", Proc. of IASS Symposium, Istanbul, 523-530, 5.
  6. Kawaguchi, M., Abe, M. and Tatemichi, I. (1999). "Design, tests and realization of "Suspen-dome" System", J. IASS, 40(131), 179-192.
  7. Kmet, S. and Mojdis, M. (2015), "Adaptive cable dome", J. Struct. Eng., 141(9), 1-16.
  8. Lee, K., Lee, S.H., Kim, G.C. and Woo, S.S. (2014), "Global vertical resonance phenomenon between steel building and human rhythmic excitations", J. Constr. Steel Res., 92, 164-174. https://doi.org/10.1016/j.jcsr.2013.09.001
  9. Li, Z.X. (2004), Theory and Technique of Engineering Structure Experiments. Tianjin University Press, TianJin, China.
  10. Masao, S. and Kurasiro, T. (1985), "A study on structural behaviors of beam string structure", Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, B.1, Tokyo, Japan, 280-284, 6.
  11. Mello, A.V.A., Silva, J.G.S.D., Vellasco, P.C.G.D.S., Andrade, S.A.L.D. and Lima, L.R.O.D. (2008), "Dynamic analysis of composite systems made of concrete slabs and steel beams", J. Constr. Steel Res., 64(10), 1142-1151. https://doi.org/10.1016/j.jcsr.2007.09.011
  12. Ouni, M.H.E.I. and Kahla, N.B. (2014), "Active tendon control of a Geiger dome", J. Vib. Control, 20(2), 241-255. https://doi.org/10.1177/1077546312458944
  13. Qiao, W.T., Chen, Z.H. and Zhao, M.S. (2012), "Test study on basic static characteristics of cable supported barrel vault structure", J. Adv. Steel Constr., 8(2), pp.199-211.
  14. Silva, J.G.S.D., Andrade, S.A.L.D. and Elvis, D.C.L. (2014), "Parametric modelling of the dynamic behavior of a steel-concrete composite floor", Eng. Struct., 75(75), 327-339. https://doi.org/10.1016/j.engstruct.2014.06.010
  15. Silva, S.S.D. and Thambiratnam, D.P. (2009), "Dynamic characteristics of steel-deck composite floors under human-induced loads", Comput. Struct., 87(17-18), 1067-1076. https://doi.org/10.1016/j.compstruc.2009.04.005
  16. Varela, W.D. and Battista, R.C. (2011). "Control of vibrations induced by people walking on large span composite floor decks", Eng. Struct., 33(9), 2485-2494. https://doi.org/10.1016/j.engstruct.2011.04.021
  17. Yan, R.Z., Chen, Z.H., Wang, X.D., Liu, H.B. and Xiao, X. (2015), "A new equivalent friction element for analysis of cable supported structures", Steel Compos. Struct., 18(4), 947-970. https://doi.org/10.12989/scs.2015.18.4.947
  18. Zhao, X.Z., Yan, S. and Xu, Z.Y. and Wu, A.H. (2015). "Research and application of beam string structures", Struct. Eng. Int., 25(1), 26-33. https://doi.org/10.2749/101686614X14043795570219