This study measured the amount of electricity consumed by the vending machines installed on campus and aim to come up with measures to address excessive consumption of electricity. We chose 10 universities located in the city of Seoul and Gyeonggi province and measured electricity consumption of 10 vending machines installed in each university. We then calculated annual electricity consumption of the machines based on previously calculated electricity consumption of 100 samples. According to the result of the calculation, it is estimated that the machines studied on consume 700 KWh a year. This amount could translate into approximately 3,000 tons of annual carbon emissions and 640 million KRW in annual electricity bills. It was also found that there is a significant difference between ordinary vending machines and machines certified for being eco-friendly and energy efficient, in terms of electric power consumption. It is expected that, if the ordinary machines are replaced with the eco-friendly and high-efficient machines, 640 KWh of electricity, 300 kg of carbon, and 61,640 KRW in electricity bills would be saved, which means 28% saving in energy, emissions and bills. In conclusion, we determined that, as one of the ways to reduce electric power consumption and carbon emissions, old vending machines on campus could be replaced with eco-friendly and high-efficient machines.