Acknowledgement
Supported by : 국토교통부
References
- ISO. (2012). ISO 10077-2 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames.
- ISO. (2012). ISO 13788 Hygrothermal performance of building components and building elements - Internal surface temperature to avoid critical surface humidity and interstitial condensation - Calculation methods.
- ISO. (2007). ISO 6946 Building components and building elements - Thermal resistance and thermal transmittance - Calculation method.
- Jang, D. B., & Hong, G. P. (2012). Study of the Variety Tests of the Condensation for Windows at the Residential Building, Journal of Architectural Institute of Korea, 28(6), 283-290.
- Jang, H. I., Ann, H. J., Kang, H. S., Choi, C. H., & Suh, S. J. (2015). Comparison of U-Value on Different Part According to Window-Set Simulation Criterion, Journal of Korean Institute of Architectural sustainable Environment and Building Systems, 9(5), 227-284.
- Kim S. K., Lee, J. S., & Sung, K. C. (2012) A Study on Window Condensation Risk Prediction and Reduction Method using Simulation in Apartment Housing, Korean Institute of Architectural sustainable Environment and Building Systems, 2012 Autumn conference proceeding, 252-255.
- Koo, S. Y. (2015). Comparative Analysis of Window Thermal Performance Calculation Method between Window Certification Systems, Journal of Architectural Institute of Korea, 31(9), 119-126.
- Korean Standard Association(2014). KS F 2278 Standard test method for thermal resistance for windows and doors.
- Korean Standard Association(2004). KS F 2295 Test method of dew condensation for windows and doors.
- Ministry of Land, Infrastructure and Transportation(2015). Korean design standard for energy-efficient building design, Notification No. 2015-1108.
- Ministry of Land, Infrastructure and Transportation(2016). Korean design standard for preventing condensation in apartment buildings No. 2016-238.
- Park, S. H., Kim, M. H., Lim, J. H., & Song, S. Y. (2016). Condensation Resistance and Air-tightness Test Evaluations of Triple Glazing Windows with and without Drainage Holes, Journal of Korean Institute of Architectural sustainable Environment and Building Systems, 10(1), 30-36.
- Park, S. H.,, Koo, S. Y., Lim, J. H., Seong, Y. B., & Song, S. Y. (2016). Condensation resistance evaluation of a double-sliding window system for apartment buildings, Procedia Engineering, 146, 60-68. https://doi.org/10.1016/j.proeng.2016.06.353
- Song, J. H., Lim, J. H., & Song, S. Y. (2016). Evaluation of alternatives for reducing thermal bridges in metal panel curtain wall systems, Energy and Buildings, 127, 138-158. https://doi.org/10.1016/j.enbuild.2016.05.078
- Song, S. Y., Jo, J. H., Yeo, M. S., Kim, Y. D., & Song, K. D. (2007). Evaluation of inside surface condensation in double glazing window system with insulation spacer: A case study of residential complex, Building and Environment, 42(2), 940-950. https://doi.org/10.1016/j.buildenv.2005.10.015