DOI QR코드

DOI QR Code

Seismic behavior of composite walls with encased steel truss

  • Wu, Yun-tian (Key Laboratory of New Technology for Construction of Cities in Mountain Area, Ministry of Education) ;
  • Kang, Dao-yang (School of Civil Engineering, Chongqing University) ;
  • Su, Yi-ting (School of Civil Engineering, Chongqing University) ;
  • Yang, Yeong-bin (School of Civil Engineering, Chongqing University)
  • 투고 : 2015.12.17
  • 심사 : 2016.10.13
  • 발행 : 2016.10.10

초록

This paper studies the seismic behavior of reinforced concrete (RC) walls with encased cold-formed and thin-walled (CFTW) steel truss, which can be used as an alternative to the conventional RC walls or steel reinforced concrete (SRC) composite walls for high-rise buildings in high seismic regions. Seven one-fourth scaled RC wall specimens with encased CFTW steel truss were designed, manufactured and tested to failure under reversed cyclic lateral load and constant axial load. The test parameters were the axial load ratio, configuration and volumetric steel ratio of encased web brace. The behaviors of the test specimens, including damage formation, failure mode, hysteretic curves, stiffness degradation, ductility and energy dissipation, were examined. Test results indicate that the encased web braces can effectively improve the ductility and energy dissipation capacity of RC walls. The steel angles are more suitable to be used as the web brace than the latticed batten plates in enhancing the ductility and energy dissipation. Higher axial load ratio is beneficial to lateral load capacity, but can result in reduced ductility and energy dissipation capacity. A volumetric ratio about 0.25% of encased web brace is believed cost-effective in ensuring satisfactory seismic performance of RC walls. The axial load ratio should not exceed the maximum level, about 0.20 for the nominal value or about 0.50 for the design value. Numerical analyses were performed to predict the backbone curves of the specimens and calculation formula from the Chinese Code for Design of Composite Structures was used to predict the maximum lateral load capacity. The comparison shows good agreement between the test and predicted results.

키워드

과제정보

연구 과제 주관 기관 : National Science Foundation of China, Chongqing Science and Technology Commission

참고문헌

  1. Cao, W.L., Zhang, J.W., Dong, H.Y. and Deng, T.L. (2009), "Seismic performance of high-rise shear wall with concealed truss", J. Harbin Inst. Technol., 41(4), 153-158.
  2. China Ministry of Construction (2003), GB500017-2003, Code for design of steel structures, Beijing, China.
  3. China Ministry of Construction (2010), GB500010-2010, Code for design of concrete structures, Beijing, China.
  4. China Ministry of Construction (2011), GB500010-2011, Code for seismic design of buildings, Beijing, China.
  5. China Ministry of Construction (2012), JGJ138-2012, Code for design of composite structures, Beijing, China.
  6. Dan, D., Fabian A. and Stoian, V. (2011), "Theoretical and experimental study on composite steel-concrete shear wall with vertical steel encased profiles", J. Constr. Steel Res., 67(5SI), 800-813. https://doi.org/10.1016/j.jcsr.2010.12.013
  7. Dazio, A., Beyer, K. and Bachmann, H. (2009), "Quasi-static cyclic tests and plastic hinge analysis of RC structural walls", Eng. Struct., 31(7), 1556-1571. https://doi.org/10.1016/j.engstruct.2009.02.018
  8. DIANA Version 9.4.4 (2012), Finite element analysis user's manual-nonlinear analysis; TNO Building and Construction Research, Delft, the Netherlands.
  9. Eom, T.S., Park, H.G., Lee, C.H., Kim, J.H. and Chang, I.H. (2009), "Behavior of double skin composite wall subjected to in-plane cyclic loading", J. Struct. Eng., 135(10), 1239-1249. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000057
  10. Feenstra, P.H. (1993), "Computational aspects of biaxial stress in plain and reinforced concrete", Ph.D. Thesis; Delft University of Technology, Delft, The Netherlands.
  11. Hines, E.M., Seible, F. and Priestley, M.J.N. (2002), "Cyclic tests of structural walls with highly-confined boundary elements", Report No. SSRP-2001/27; University of California, San Diego, CA, USA.
  12. Nie, J.G., Hu, H.S., Fan, J.S., Tao, M.X., Li, S.Y. and Liu, F.J. (2013), "Experimental study on seismic behavior of high strength concrete filled double-steel-plate composite walls", J. Constr. Steel Res., 88(9), 206-219. https://doi.org/10.1016/j.jcsr.2013.05.001
  13. Park, R. (1988), "Ductility evaluation from laboratory and analytical testing", Proceedings of the 9th World Conference on Earthquake Engineering, Tokyo-Kyoto, Japan, August, pp. 605-616.
  14. Rafiei, S., Hossain, K.M.A., Lachemi, M. and Behdinan, K. (2015), "Composite wall with high performance concrete subjected to monotonic shear", J. Constr. Steel Res., 107, 124-136. https://doi.org/10.1016/j.jcsr.2015.01.015
  15. Sayre, B. (2003), "Performance evaluation of steel reinforced shear walls", Thesis for the degree of Master of Science; University of California, Los Angeles, CA, USA.
  16. Thomas, T. (1993), CEB-FIP Model Code-1990; CEB Bulletin No. 213-214, Lausanne, Switzerland.
  17. Thomsen, J.H. and Wallace, J.W. (2004), "Displacement-based design procedures for slender reinforced concrete structural walls-experimental verification", J. Struct. Eng., 130(4), 618-630. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:4(618)
  18. Vallenas, J.M., Bertero, V.V. and Popov, E.P. (1979), "Hysteretic behaviour of reinforced concrete structural walls", Report No. UBC/EERC-79/20; University of California, Berkeley, CA, USA.
  19. Zhao, Q.H. and Astaneh-Asl, A. (2004), "Cyclic behavior of traditional and innovative composite shear walls", J. Struct. Eng., 130(2), 271-284. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:2(271)

피인용 문헌

  1. Bending behavior of SWCNT reinforced composite plates vol.24, pp.5, 2016, https://doi.org/10.12989/scs.2017.24.5.537