DOI QR코드

DOI QR Code

7 T 자기공명영상시스템에서의 송수신 RF 공진기 최적화

Transmit Receive RF Resonator Optimization at 7 T MRI System

  • 투고 : 2016.08.30
  • 심사 : 2016.09.28
  • 발행 : 2016.10.01

초록

Magnetic resonance imaging has a potential to produce clear anatomical as well as functional images of human body. However, the ability to diagnose is limited by signal to noise ratio (SNR) and the resolution of current medical systems. To remove the challenges prevalent due to the use of high field scanners, dedicated radio frequency coils are used. Transverse electromagnetic coils have an advantage of providing homogeneous magnetic field throughout the region but with low signal to noise ratio while surface coils have an advantage of providing higher signal to noise ratio but with low homogeneity. This research combines both the advantage into one by utilizing transmit only transverse electromagnetic radio frequency coils (8 channel) along with receive only surface coils (by varying the number) for better imaging of brain. A 7 Tesla 32-channel close fitting helmet shaped phased-array surface coils along with the combination of 8 channel transmit only transverse electromagnetic coils provided good homogeneity as well as significant SNR improvements throughout the human brain.

키워드

참고문헌

  1. J. Vaughan, M. Garwood, C.M. Collins, W. Liu, L. DelaBarre, G. Adriany, P. Andersen, H. Merkle, R. Goebel, M.B. Smith, and K. Ugurbil, "7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images," Magn Reson Med, vol. 46, no. 1, pp. 24-30, Jul. 2001. https://doi.org/10.1002/mrm.1156
  2. J. Vaughan, L. DelaBarre, C. Snyder, J. Tian, C. Akgun, D. Shrivastava, W. Liu, C. Olson, G. Adriany, J. Strupp, P. Anderson, A. Gopinath, and P. Moortele, "9.4 T human MRI: Preliminary results," Magn. Reson Med., vol. 56, pp. 1274-1282, Oct. 2006 https://doi.org/10.1002/mrm.21073
  3. H. Yoo, A. Gopinath, and J. T. Vaughan, "A method to localize RF B1 field in high-field magnetic resonance imaging systems," IEEE Trans. on Biomed. Eng., vol. 59, no.12, pp.3365-3371, Dec. 2012 https://doi.org/10.1109/TBME.2012.2208965
  4. J. T. Vaughan and J. R. Griffiths, "RF coils for MRI", Wiley, Aug. 2012.
  5. W. Zhao, J. Cohen-Adad, J. R. Polimeni, B. Keil, B. Guerin, K. Setsompop, P. Serano, A. Mareyam, P. Hoecht, and L.L. Wald, "Nineteen-channel receive array and four-channel transmit array coil for cervical spinal cord imaging at 7 T", Magn Reson Med, vol. 72, no 1, pp. 291-300, Jul. 2014. https://doi.org/10.1002/mrm.24911
  6. SEMCAD X by SPEAG, www.speag.com