Establishment of Test & Evaluation Criteria in the Military Electro-Optical / Infrared Devices

군용 EO/IR장비의 시험평가 기준 정립방안

  • Park, Jong Wan (Department of Defense Acquisition Program, University of Konkuk)
  • 박종완 (건국대학교 방위사업학과)
  • Received : 2016.02.15
  • Accepted : 2016.08.19
  • Published : 2016.10.05

Abstract

Development-concerned parties, business managers and test evaluators have experienced conflicts among themselves due to the absence of standardized criteria for military electro-optical(EO) and infrared(IR) devices in test evaluation planning and evaluation phases. Therefore, establishment of objectified test and evaluation criteria for EO/IR devices is required. This paper applies South Korea's weather measurement average of minimum 15 km for visibility range, 3 bar from Johnson criteria for EO device and 4 bar from NATO's STANAG-4347 for IR device for target type, and 50 % probability for evaluation criteria, respectively. Based upon these criteria, this paper will establish suitable criteria that are improved for development weapon system in consideration of required capability of demanding forces and field environment.

Keywords

References

  1. G. Holst, "Electro-Optical Imaging System Performance," SPIE Optical Engineering Press, p. 420, 2003.
  2. NATO STANAG-4347, "Definition of Nominal STATIC Range Performance for Thermal Imaging System," pp. 1-3, 1996.
  3. Defense Acquisition University, "Test and Evaluation Management Guide," pp. 86/122, 2012.
  4. NATO STANAG-7194, "NATO Imagery Interpretability Rating Scale(NIRS)," 2009.
  5. Y. Lee, "Dispersion of Average Annual Visibility Range of the Korean Peninsula", Weather Studies, Vol(1), pp. 23-28, 2006.
  6. ADD, "Defense Science and Technology Academy Textbook," p. 463, 2015.
  7. C. Lee, "Introduction to Optics and Lasers," Gongju University Press, pp. 206-220, 2013.