참고문헌
- M. Humphreys, M. Teressa, G. Urbano, et al: Assessment of a customised immobilisation system for head and neck IMRT using electronic portal imaging. Radiother. Oncol. 77(1): 39-74 (2005) https://doi.org/10.1016/j.radonc.2005.06.039
- L. N. McDermott, M. Wendling, J. J. Sonke, M. Herk, B. J. Mijnheer: Replacing pretreatment verification with in vivo EPID dosimetry for prostate IMRT. Int. J. Radiat. Oncol. Biol. Phys. 67(5): 1568-1577 (2007) https://doi.org/10.1016/j.ijrobp.2006.11.047
- M. Oldham, J. H. Siewerdsen, S. Kumar, J. Wong, D. A. Jaffray: Optical-CT gel-dosimetry I: basic investigations. Med. Phys. 30(4): 623-634 (2003) https://doi.org/10.1118/1.1559835
- Nikola Krstaji'c, Simon J. Doran: Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry. Phys. Med. Biol. 51: 2055-2075 (2006) https://doi.org/10.1088/0031-9155/51/8/007
- A. Jirasek, D. Rudko, D. Wells, Journal of Physics: A prototype fan-beam optical CT scanner for polymer gel dosimetry. Conference Series 164: 1-6 (2009)
- Nikola Krstaji'c, Simon J Doran: Fast laser scanning optical-CT apparatus for 3D radiation dosimetry. Phys. Med. Biol. 52: 257-263 (2007) https://doi.org/10.1088/0031-9155/52/1/017
- S. J. Doran, N. Krstajic: The history and principles of optical computed tomography for scanning 3-D radiation dosimeters. Journal of Physics: Conference Series 56: 45-57 (2006) https://doi.org/10.1088/1742-6596/56/1/005
- Timothy Olding, Oliver Holmes, L John Schreiner: Cone beam optical computed tomography for gel dosimetry I: Scanner characterization. Phys. Med. Biol. 55: 2819-2840 (2010) https://doi.org/10.1088/0031-9155/55/10/003
- M. Hilts, A. Jirasek, C. Duzenli: Technical considerations for implementation of X-ray CT polymer gel dosimetry. Phys. Med. Biol, 50: 1727-1745 (2005) https://doi.org/10.1088/0031-9155/50/8/008
- K. H. Cho, S. J. Cho, S. Lee, S. H. Lee, C. K. Min: Dose responses in a normoxic polymethacrylic acid gel dosimeter using optimal CT scanning parameters. Nucl. Instr. and Meth. A 675: 112-117 (2012) https://doi.org/10.1016/j.nima.2012.01.067
- Y. R. Cho, H. W. Park, A. R. Kim, et. al: Fabrication of a Normoxic Polymer Gel Dosimeter and its Dose Distribution Characteristics. J. Korean Phys. Soc. 59(1): 169-175 (2011) https://doi.org/10.3938/jkps.59.169
- A. R. Kim: Optical computed tomography for 3D gel dosimetry. MS thesis, Kyonggi University (2011)
- J. C. Lee: Image characteristic of optical computed tomography. MS thesis, Kyonggi University (2011)
- S. J. Doran, K. K. Koerkamp, M. A. Bero, et al: A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results. Phys. Med. Biol. 46(12):3191-213 (2001) https://doi.org/10.1088/0031-9155/46/12/309
-
Corey Clift, Andrew Thomas, John Adamovics, Zheng Chang, Indra Das: Toward acquiring comprehensive radiosurgery field commissioning data using the
$PRESAGE^{(R)}/optical-CT$ 3D dosimetry system. Phys. Med. Biol. 55(5):1279-1293 (2010) https://doi.org/10.1088/0031-9155/55/5/002 - Gustavsson H, Back S A J, Lepage M, Rintoul L, Baldock C: Development and optimization of a 2-hydroxyethylacrylate MRI polymer gel dosimeter. Phys. Med. Biol. 49:227-241 (2004) https://doi.org/10.1088/0031-9155/49/2/004
피인용 문헌
- Basic radiological characteristics of a non-scattering gel dosimeter for 3D dosimetry vol.69, pp.11, 2016, https://doi.org/10.3938/jkps.69.1694