References
- ASCE (2013), Minimum Design Loads for Buildings and Other Structures SEI/ASCE 7-10, American Society of Civil Engineers, Washington DC, USA.
- Banerji, P., Murudi, M., Shah, A.H. and Popplewell, N. (2000), "Tuned liquid dampers for controlling earthquake response of structures", Earthq. Eng. Struct. Dyn., 29(5), 587-602. https://doi.org/10.1002/(SICI)1096-9845(200005)29:5<587::AID-EQE926>3.0.CO;2-I
- Chen, Y.H., Hwang, W.S., Chiu, L.T. and Sheu, S.M. (1999) , "Flexibility of TLD to high-rise building by simple experiment and comparison", Comput. Struct., 57(5), 855-861. https://doi.org/10.1016/0045-7949(95)00083-S
- Deng, X. and Tait, M.J. (2009) , "Theoretical modeling of TLD with different tank geometries using linear long wave theory", J. Vib. Acoust. Tran., ASME, 131(4), 041014. https://doi.org/10.1115/1.3142873
- Ding, X., Idir, M., Lou, M. and Chen, G. (2009). "Experimental study on the seismic performance of a largescale TLD model with sloped bottoms", Proceedings of the 2009 Structures Congress 9@ sDon't Mess with Structural Engineers: Expanding Our Role, ASCE, 1-10.
- Fediw, A. (1992), "Performance of a one dimensional tuned sloshing water damper", Master Thesis, University of Western Ontario, London, Canada.
- Hamelin, J. (2007), "The effect of screen geometry on the performance of a tuned liquid damper", Master Thesis, McMaster University, Canada.
- Hamelin, J.A., Love, J.S., Tait, M.J. and Wilson J.C. (2013), "Tuned liquid dampers with a Keulegan-Carpenter number-dependent screen drag coefficient", J. Fluid. Struct., 43, 271-286. https://doi.org/10.1016/j.jfluidstructs.2013.09.006
- Housner, G.W. (1963), "The dynamic behavior of water tanks", Bull. Seismol. Soc. Amer., 53(2), 381-387.
- Kareem, A. and Kijewski, T. (1999), "Mitigation of motions of tall buildings with specific examples of recent applications", Wind Struct., 2(3), 201-251. https://doi.org/10.12989/was.1999.2.3.201
- Kim, Y.M., You, K.P., Cho, J.E. and Hong, D.P. (2006), "The vibration performance experiment of tuned liquid damper and tuned liquid column damper", J. Mech. Sci. Technol., 20(6), 795-805. https://doi.org/10.1007/BF02915943
- Lamb, H. (1932), Hydrodynamics Cambridge University Press, Cambridge, UK.
- Lee, S.K., Park, E.C., Min, K.W., Lee, S.H., Chung, L. and Park, J.H. (2007), "Real-time hybrid shaking table testing method for the performance evaluation of a tuned liquid damper controlling seismic response of building structures", J. Sound Vib., 302, 596-612. https://doi.org/10.1016/j.jsv.2006.12.006
- Min, K.W., Kim, J. and RiLee, H. (2013) "A design procedure of two-way liquid dampers for attenuation of wind-induced responses of tall buildings", J. Wind Eng. Ind. Aerodyn., 129, 22-30.
- Noji, T., Yoshida, H., Tatsumi, E., Kosaka, H. and Hagiuda, H. (1988), "Study on vibration control damper utilizing sloshing of water", J. Wind Eng. Ind. Aerodyn., 37, 557-566.
- Shad, H. (2015), "Performance of tuned liquid damper with baffle in reduction of structural dynamic response", PhD Dissertation, Universiti Teknologi Malaysia, Skudai.
- Soong, T.T. and argush, G.F. (1997), Passive Energ yDissipation Systems in Structural Engineering, John Wiley and Sons, USA.
- Sorkhabi, A.A., Kristie, J. and Mercan, O. (2014), "Investigations of the use of multiple tuned liquid dampers in vibration control", Structures Congress 2014, 1185-1195.
- Sun, L.M. (1991), "Semi-analytical modelling of Tuned Liquid Damper (TLD) with emphasis on damping of liquid sloshing", University of Tokyo.
- Sun, L.M., Fujino, Y. and Pacheco, B.M. (1989), "Nonlinear waves and dynamic pressure in rectangular tuned liquid damper (TLD): simulation and experimental verification", Struct. Eng., Earthq. Engin., 6(2), 81-92.
- Tait, M. (2008), "Modelling and preliminary design of a structure-TLD system", Eng. Struct., 30(10), 2644-2655. https://doi.org/10.1016/j.engstruct.2008.02.017
- Tait, M., Isyumov, N. and El Damatty, A. (2007), "Effectiveness of a 2D TLD and its numerical modeling", J. Struct. Eng., 133(2), 251-263. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:2(251)
- Tait, M., Isyumov, N. and El Damatty, A.A. (2007), "Effectiveness of a 2D TLD and its numerical modelling", J. Struct. Eng., 133(2), 251-263. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:2(251)
- Tamura, Y., Kohsaka, R., Nakamura, O., Miyashita, K.I. and Modi, V.J. (1996), "Wind-induced responses of an airport tower-efficiency of tuned liquid damper", J. Wind Eng. Ind. Aerodyn., 65(1), 121-131. https://doi.org/10.1016/S0167-6105(97)00028-7
- Wang, J.T., Gui, Y., Zhu, F., Jin, F. and Zhou, M.X. (2016), "Real-time hybrid simulation of multi-story structures installed with tuned liquid damper", Struct. Control Hlth., 23, 1015-1031. https://doi.org/10.1002/stc.1822
- Xin, Y., Chen, G. and Lou, M. (2009), "Seismic response control with density-variable tuned liquid dampers", Earthq. Eng. Eng. Vib., 8(4), 537-546. https://doi.org/10.1007/s11803-009-9111-7
- Zahrai, S.M., Abbasi, S., Samali, B. and Vrcelj, Z. (2012), "Experimental investigation of utilizing TLD with baffles in a scaled down 5-story benchmark building", J. Fluid. Struct., 28, 194-210. https://doi.org/10.1016/j.jfluidstructs.2011.08.016
Cited by
- Experimental investigation of the effect of baffles on the efficiency improvement of irrigation sedimentation tank structures vol.63, pp.4, 2016, https://doi.org/10.12989/sem.2017.63.4.567
- Seismic control of structures using sloped bottom tuned liquid dampers vol.64, pp.2, 2017, https://doi.org/10.12989/sem.2017.64.2.233
- Experimental study on a new damping device for mitigation of structural vibrations under harmonic excitation vol.14, pp.6, 2016, https://doi.org/10.12989/eas.2018.14.6.567
- Seismic performance evaluation of steel frame structures equipped with tuned liquid dampers vol.19, pp.8, 2016, https://doi.org/10.1007/s42107-018-0082-8
- Comparison between cyclic response of RC columns transversely reinforced with FRP strips and carbon steel vol.513, pp.None, 2016, https://doi.org/10.1088/1757-899x/513/1/012021