DOI QR코드

DOI QR Code

Seismic vulnerability assessment of composite reinforced concrete-masonry building

  • Remki, Mustapha (Department of Civil Engineering, National Earthquake Engineering Research Center, CGS) ;
  • kehila, Fouad (Department of Civil Engineering, National Earthquake Engineering Research Center, CGS) ;
  • Bechtoula, Hakim (Department of Civil Engineering, National Earthquake Engineering Research Center, CGS) ;
  • Bourzam, Abdelkrim (Faculty of Civil Engineering, University of Sce & Technology USTHB)
  • Received : 2014.09.14
  • Accepted : 2016.08.13
  • Published : 2016.08.25

Abstract

During the last decades, many destructive earthquakes occurred in Algeria, particularly in the northern part of the country (Chlef (1980), Constantine (1985), Tipaza (1989), Mascara (1994), Ain-Benian (1996), Ain Temouchent (1999), Beni Ourtilane (2000), and recently $Boumerd{\acute{e}}s$ (2003), causing enormous losses in human lives, buildings and equipments. In order to reduce this risk and avoid serious damages to the strategic existing buildings, the authorities of the country, aware of this risk and in order to have the necessary elements that let them to know and estimate the potential losses in advance, with an acceptable error, and to take the necessary countermeasures, decided to invest into seismic upgrade, strengthening and retrofitting of those buildings. To do so, seismic vulnerability study of this category of buildings has been considered. Structural analysis is performed based on the site investigation (inspection of the building, collecting data, materials characteristics, general conditions of the building, etc.), and existing drawings (architectural plans, structural design, etc.). The aim of these seismic vulnerability studies is to develop guidelines and a methodology for rehabilitation of existing buildings. This paper presents the methodology, based on non linear and seismic analysis of existing buildings, followed in this study and summarizes the vulnerability assessment and strengthening of one of the strategic buildings according to the new Algerian code RPA 99/version 2003. As a direct application of this methodology, both, static equivalent method and non linear dynamic analysis, of composite concrete masonry existing building in the city of "CONSTANTINE", located in the east side of ALGERIA, are presented in this paper.

Keywords

Acknowledgement

Supported by : National Earthquake Engineering Research Center C.G.S.

References

  1. Calvi, G.M. (2013), "Choices and criteria for seismic strengthening", J. Earthq. Eng., 17(6), 769-802. https://doi.org/10.1080/13632469.2013.781556
  2. Fajfar, P. and Kreslin, M. (2010), "Seismic evaluation of an existing complex RC building", Bull. Earthq. Eng., 8(2), 363-385. https://doi.org/10.1007/s10518-009-9155-0
  3. Fillitsa Karantoni, Georgios Tsionis, Foteini Lyrantzaki and Michael N. Fardis (2014), "Seismic fragility of regular masonry buildings for in-plane and out-of-plane failure", Earthq. Struct., 6(6), 689-713. https://doi.org/10.12989/eas.2014.6.6.689
  4. Gesualdo, A. and Monaco, M. (2011), "Seismic retrofitting techniques for existing masonry buildings", J. Civ. Eng. Architec., 5(11), 1011-1018.
  5. Gorgulu, T., Tama, Y.S., Yilmaz, S. and Kaplan, H. (2011), "Strengthening of reinforced concrete structures with external steel shear walls", J. Constr. Steel Res., 70, 226-235.
  6. Iskhakov, I., Ribakov, Y., Holschemacher, K. and Mueller T. (2013), "High performance repairing of reinforced concrete structures", Mater. Des., 44(1), 216-222. https://doi.org/10.1016/j.matdes.2012.07.041
  7. Kaplan, H., Yilmaz, S., Cetinkaya, N. and Atimtay, E. (2011), "Seismic strengthening of RC structures with exterior shear walls", Sadhana-Academy Proc. Eng. Sci., 36(1), 17-34.
  8. Ousalem, H. and Bechtoula, H. (2005), "Inventory survey of the 2003 Zemmouri (Algeria) Earthquake: Case Study of Dergana City", J. Adv. Concrete Technol., 3(1), 175-183. https://doi.org/10.3151/jact.3.175
  9. Preciado, A., Ramirez-Gaytan, A., Salido-Ruiz, R., Caro-Becerra, J. and Lujan-Godinez, R. (2015), "Earthquake risk assessment methods of unreinforced masonry structures: Hazard and vulnerability", Earthq. Struct., 9(4), 719-733. https://doi.org/10.12989/eas.2015.9.4.719
  10. Ranjbaran, F. and Hosseini, M. (2014), "Seismic vulnerability assessment of confined masonry wall buildings", Earthq. Struct., 7(2), 201-216. https://doi.org/10.12989/eas.2014.7.2.201
  11. Sezen, H. (2012), "Repair and strengthening of reinforced concrete beam-column joints with fiberreinforced polymer composites", J. Compos. Constr., 16(5), 499-506. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000290
  12. CPW department (2007), Handbook on seismic retrofit of buildings, Indian institute of technology-madras, India.
  13. Wilson, E. and Habibullah, A. (2009), "Three dimensional static and dynamic analysis of structures", SAP2000v14 Computers and Structures, Inc Berkeley, California, USA.
  14. Belazougui, M., Farsi, M.N., Remas, A., Bensaibi, M. and Mezazigh, B. (2004), "Seismic risk assessment of current buildings of Algiers city", Proceedings of the13th WCEE, Vancouver, B.C., Canada.
  15. Bozinovski, Z. and Gavrilovic, P. (1993a), "Computer program for static, dynamic and ultimate analysis of masonry buildings SDUAMB", Institute of Earthquake Engineering and Engineering Seismology, Skopje Republic of Macedonia. Technical report.
  16. Bozinovski, Z. and Gavrilovic, P. (1993b), "Computer program for analysis of ultimate state of reinforced concrete systems UARCS", Institute of Earthquake Engineering and Engineering Seismology, Skopje Republic of Macedonia. Technical report.
  17. Bozinovski, Z. and Gavrilovic, P. (1993c), "Computer program for dynamic response analysis of buildings structures DRABS", Institute of Earthquake Engineering and Engineering Seismology, Skopje Republic of Macedonia, Technical report.
  18. IIZIS / CGS (1993), "Methodology and vulnerability study of strategic buildings in the city of Algiers", Institute of Earthquake Engineering and Engineering Seismology, Skopje Republic of Macedonia. Technical report.
  19. CGS (2003), "Seismic code for building design and construction, R.P.A 99/ Version 2003", National Earthquake Engineering Research Centre, Algiers, Algeria.
  20. FEMA 273 (1997), "NEHRP Guidelines for the Seismic rehabilitation of buildings", Applied Technology Council, USA.

Cited by

  1. Insights from existing earthquake loss assessment research in Croatia vol.13, pp.4, 2016, https://doi.org/10.12989/eas.2017.13.4.365
  2. Seismic performance of retrofitted URM walls with diagonal and vertical steel strips vol.14, pp.5, 2018, https://doi.org/10.12989/eas.2018.14.5.449