과제정보
연구 과제 주관 기관 : Korea Agency for Infrastructure Technology Advancement (KAIA)
참고문헌
- AASHTO (American Association of State Highway and Transportation Officials) (2002), Specifications for Highway Bridges, 17th Edition, AASHTO, Washington D.C., USA.
- AASHTO (American Association of State Highway and Transportation Officials) (2010), AASHTO LRFD Bridge Design Specifications, AASHTO, Washington D.C., USA.
- ACI 318-14 (2014), Building code requirements for structural concrete and commentary, American Concrete Institute; Farmington Hills, MI, USA.
- ASTM C1609/C1609M-12 (2012), Standard test method for flexural performance of fiber-reinforced concrete (using beam with third-point loading), ASTM International Standard Worldwide, West Conshohocken, PA.
- Breen, J.E. (1994), "Anchorage zone reinforcement for post-tensioned concrete girder", NCHRP Report 356, Transportation Research Board, Washington D.C., USA.
- Cervenka, V. and Ganz, H.R. (2014), "Validation of post-tensioning anchorage zones by laboratory testing and numerical simulation", Struct. Concrete, 15(2), 258-268. https://doi.org/10.1002/suco.201300038
- EOTA (European Organisation for Technical Approvals) (2002), ETAG 013: Guideline for European technical approval of post-tensioning kits for prestressing of structures, EOTA, Brussels, Belgium.
- Guyon, Y. (1953), Prestressed Concrete, Wiley, NJ, USA.
- Kim, J.K., Seong, T.R., Jang, K.P. and Kwon, S.H. (2013), "Tensile behavior of new 2,200 MPa and 2,400 MPa strands according to various types of mono anchorage", Struct. Eng. Mech., 47(3), 383-399. https://doi.org/10.12989/sem.2013.47.3.383
- KS D 3504 (2011), Steel bars for concrete reinforcement, Korean Standards Association, Seoul, Korea.
- KS D 7002 (2011), Uncoated stress-relieved steel wires and strands for prestressed concrete, Korean Standards Association, Seoul, Korea.
- Morgan, D.R., Mindess, S. and Chen, L. (1995), "Testing and specifying toughness for fiber reinforced concrete and shotcrete", Proceedings of 2nd University - Industry Workshop on Fiber-Reinforced Concrete and Other Advanced Composites, Fiber-Reinforced Concrete - Modern Developments, Toronto.
- PTI (Post-Tensioning Institute) (2006), Post-Tensioning Manual, 6th Edition, PTI.
- Richart, F.E., Brandtzaeg, A. and Brown, R.L. (1928), "A study of the failure of concrete under combined compressive stresses", Research Bulletin No. 185; Univ. of Illinois Engineering Experimental Station, USA.
- Roberts-Wollmann, C.L. (2000), "Design and test specifications for local tendon anchorage zones", ACI Struct. J., 97(6), 867-875.
- Roberts, C.L. (1990), "Behavior and design of the local anchorage zone of post-tensioned concrete members", Master's Thesis, University of Texas at Austin, USA.
- Sanders, D.H. (1990), "Design and behavior of anchorage zones in post-tensioned concrete members", Doctoral dissertation, University of Texas at Austin, USA.
피인용 문헌
- Load Carrying and Hydrostatic Performances of Innovative Encapsulated Anchorage System for Unbonded Single Strand vol.2019, pp.None, 2016, https://doi.org/10.1155/2019/7812623
- Design equation to evaluate bursting forces at the end zone of post-tensioned members vol.24, pp.5, 2019, https://doi.org/10.12989/cac.2019.24.5.423
- Analysis of Bearing Strength of Post-Tensioning Anchorage Zone with Respect to Relative Bearing Area and Lateral Confinement Design vol.11, pp.18, 2021, https://doi.org/10.3390/app11188386