Abstract

Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Most of all, occupants in residential buildings has suffered from property damages due to the condensation and mold of built-in furniture. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. These problems are related to the weather conditions and indoor room conditions in winter. To understand these condensation problems, it is necessary to investigate the thermal environment around the built-in furniture and living spaces in winter. The aim of paper is to analyze the characteristics of adjacent area around built-in furniture's condensation problem and the thermal environment around the built-in furniture in winter through the field measurements at apartment buildings. In this research, the thermal conditions around the built-in furniture were measured during winter season. In results, it is important to consider increasing surface temperature for higher $16^{\circ}C$ and decreasing absolute humidity due to the occupants' behavior around built-in furniture for preventing condensation.

Keywords

Acknowledgement

Supported by : 국토교통부

References

  1. Hwang, H. J, Kim, J. Y., & Lee, J, S (2011). A Study on the Foundation of the Standard of Temperature and Humidity for Preventing Condensation in Apartment Housings, LHI journal 2(3), 269-276
  2. Hwang, H. J., Kim, G. T., Yoo, J. H., & Hwan, I, T. (2015). An Improvement of the Criteria for the Prevent Condensation in Apartment Houses, Journal of KIAEBS, 9(4) 319-324
  3. Kim, G. T., Kim, J. Y., Hwang, H. J., & Kim, K. S. (2014). The Design Criteria of the Indoor Temperature and Humidity for the Prevent Condensation of Small Apartment Buildings, LHI journal 5(4), 291-296
  4. Kim, S. S., Song, S., Y., Lee, J. W., & Kim, K. W. (1996). A Study on the Thermal Performance Evaluation Method for the Insulation Details of the Joints in a Apartment Building Envelope, Journal of The Architectural Insititute of Korea, 12(3) 93-102
  5. Lee, H. H., Lim, J. H., & Song, S. S. (2015). Evaluation on the Thermal Environment inside the Built-in Furniture in New Apartment Buildings in Winter, Proceeding of the Architectural Institute of Korea, 35(1), 249-250
  6. Lee, H. H., Lim, J. H., & Song, S. S. (2015). Evaluation on the Thermal Environment inside the Built-in Furniture in Apartment Buildings in Summer, Proceeding of the Architectural Institute of Korea, 35(2), 319-320
  7. Lee, S. Y. (2008). A Comparative Study on the Residential Furniture Design Preference according to Consumers Characteristics, The Journal of the Korea Contents Association 8(3) 146-155 https://doi.org/10.5392/JKCA.2008.8.3.146
  8. Moon, H. J., Park, J. W., & Yoon, Y. R. (2008). An Evaluation of Mold Growth Risks in Trouble Spots in an Apartment Building using Computer Simulation, Journal of The Architectural Insititute of Korea, 24(10) 251-258
  9. Moon, H. J., Yoon, Y. R., & Park, J. W. (2008). The Status and Cause of Mold Infestaion in Apartment Houses Based on a Case Study, Journal of Korean. Living Environment System 15(3) 331-336
  10. Oh, J. K., Sohn, J. Y., & Kim, S. W. (2008). An Experimental Study for Sound Insulation of Partition Wall between Housing Units according to Setup of Buit-in Chest of Drawers, Journal of Korean. Living Environment System 15(4) 433-439
  11. Song, D. S. (2015). Indoor Moisture Generation Rates and Ventilation Methods for Humidity Control in Multi-residential Buildings, Review of Architecture and Building Science, 59(9) 27-31
  12. Song, J. H., Lim, A. R., Song, S. Y., Lim, J. H., Yu, J. Y., & Lee, K. N. (2012). Condensation Risk Evaluation Using Surface Temperature Analysis of the Glazing System, Proceeding of KIAEBS 65-68
  13. Song, S. Y. (1998). A Study on the Method for Determining the Extent of Insulation to Prevent the Inside Surface Condensation at Thermal Bridges, Journal of the Architectural Institute of Korea 14(10) 275-284
  14. Yu, J. Y., Rhee, K. N., Kim, Y. T., Lim, A. R., Song, J. H., & Song, S. Y. (2013). Analysis of evaluation methods for the condensation resistance with window types at design stage, Proceeding of the Korean Solar Energy Society, 176-181