Purpose: The purpose of this study was to develop the accelerated life test method for Constant Electrical Potential Electrolysis gas sensor (CEPE gas sensor). Methods: The parts and modules of CEPE gas sensor were analyzed by using Reliability Block Diagram (RBD). Failure Mode and Effect Analysis (FMEA) and Quality Function Deployment (QFD) methods were performed for each part to determine the most affecting stress factor in its life cycle. The long term testing was conducted at three different dry heat levels and the acceleration factor was developed by using Arrhenius relationship. Conclusion: The acceleration factor for CEPE gas sensor was developed by using FMEA, QFD, and statistical analysis for its failure data. Also qualification tests were designed to meet the target life.

Keywords

References

  1. Baek, J. W. (2009). "Minitab Reliability". Episteme.
  2. Chung. Y. K. (1998). "A Study on th Response Properties of Thick Film Semiconductor Gas Sensor in the $WO_3$ System", Department of Inorganic Materials Engineering, Hanyang University.
  3. Kang, J. K. et al. (2006). "Development of Life Test Specification for Catalytic Gas Sensor". Journal of Applied Reliability, Vol. 6, No. 1, pp. 37-50.
  4. Kim, J. G. et al. (2000). "Reliability Analysis of Gas Sensor Based on ALT". 2,000 Spring Conference Proceedings of the Korean Reliability Society, pp. 235-241.
  5. KS C 6566. (2012). "Gas Sensors for detecting flammable gas". Korean Agency for Technology and Standards.
  6. Lee, D. D. (2009). "Chemical sensor technology". Journal of Korean Sensor Society, Vol. 18, No. 1, pp. 1-21.
  7. Meeker, W. Q. and Hahn, G. J. (1985). "How to plan an Accelerated Life Test: Some Practical Guidelines, The ASQC Basic References in Quality Control". American Society for Quality, Vol. 10.
  8. Park, J. W. et al. (2005). "Design of Environmental Tests". Journal of Applied Reliability, Vol. 5, No. 3, pp. 301-314.
  9. Park, S. R., Cho, K. H. and Lee K.W. (1990). "Simultaneous Determination of SO2/NO by Double Electrode Type Electrochemical Gas Sensor". Journal of Korean Society of Analytical Science, Vol. 3, No. 1, pp. 1-8
  10. RIC 04-05. (2006). "FMEA guideline". Reliability Innovation Center, Suwon University.
  11. RS C 0105. (2006). "Semiconductor Gas Sensor". Korea Reliability Certification Center.
  12. RS C 0106. (2006). "Combustible Gas Sensor". Korea Reliability Certification Center.
  13. Seo, S. K. (2015). "Minitab Reliability Analysis". Eretec.
  14. Yang, I. Y. et al. (2014). "Development of Accelerated Life Test Method for UHF RFID Tags for Medicine Supply Management". Journal of Applied Reliability, Vol. 14, No. 2, pp. 93-96.