DOI QR코드

DOI QR Code

Development of Digital Holographic Microscopy System for Measurements of Particle Velocities in MR Fluids

MR 유체 입자 속도 계측을 위한 디지털 홀로그래피 현미경 시스템의 개발

  • ;
  • 강보선 (전남대학교 기계공학부)
  • Received : 2016.04.09
  • Accepted : 2016.05.23
  • Published : 2016.06.30

Abstract

In this study digital holographic microscopy system for measurements of 3-D velocities of particles in MR fluid is developed. Holograms are recorded using either a CCD camera with a double pulse laser or a high-speed camera with a continuous laser. To process recorded holograms, the correlation coefficient method is used for focal plane determination of particles. To remove noise and improve the quality of holograms and reconstructed images, a Wiener filter is adopted. The two-threshold and image segmentation methods are used for binary image transformation. For particle pairing, the match probability method is adopted. The developed system will be applied to measurements of the characteristics of unsteady 3-D particle velocities in MR fluids through the next stage of this study.

Keywords

References

  1. U. Schnars and W. Jueptner, "Digital holography: digital hologram recording, numerical reconstruction, and related techniques", Springer, Berlin, 2005, pp. 80-85.
  2. P. Poddar, J. L. Wilson, H. Srikanth, J. H. Yoo, N. M. Wereley, S. Kotha, L. Barghouty and R. Radhakrishnan, "Nanocomposite magneto-rheological fluids with uniformly dispersed Fe nanoparticles", J. Nanosci. Nanotechnol., Vol. 4, 2004, pp. 192-196. https://doi.org/10.1166/jnn.2004.020
  3. Y. Yang, S. Huang and B. S. Kang, "Constitutive equation of MR fluids", J. Cent. South. Univ. Technol., Vol. 14, 2007, pp. 260-262.
  4. R. Patel, "Mechanism of chain formation in nanofluid based MR fluids", J. Magn. Magn. Mater., Vol. 323, 2011, pp. 1360-1363. https://doi.org/10.1016/j.jmmm.2010.11.046
  5. W. Jiang, Y. Zhang, S. Xuan, C. Guo and X. Gong, "Dimorphic magnetorheological fluid with improved rheological properties", J. Magn. Magn. Mater., Vol. 323, 2011, pp. 3246-3250. https://doi.org/10.1016/j.jmmm.2011.07.024
  6. H. Li, X. Peng and W. Chen, "Simulation of the chainformation process in magnetic fields", J. Intel. Mater. Syst. Struct., Vol. 16, 2005, pp. 653-658. https://doi.org/10.1177/1045389X05052598
  7. M. R Jolly, J. D. Carlson and B. C. Munoz, "A model of the behavior of magnetorheological materials", Smart Mater. Struct., Vol. 5, 1996, pp. 607-614. https://doi.org/10.1088/0964-1726/5/5/009
  8. U. Schnars and W. Jueptner, "Digital holography", Springer, 2005, pp. 41-53.
  9. Y. Yang and B. S. Kang, "Application of digital holography to sprays", Proc. Asia Display, 2007, pp. 2050-2054.
  10. F. Dubois, C. Schockaert, N. Callens and C. Yourassowsky, "Focus plane detection criteria in digital holography microscopy by amplitude analysis", Opt. Express, Vol. 14, 2006, pp. 5895-5980. https://doi.org/10.1364/OE.14.005895
  11. C. B. Lefebvre, S. Coëtmellec, D. Lebrun and C. Ozkul, "Application of wavelet transform to hologram analysis: three-dimensional location of particles", Opt. Laser Eng., Vol. 33, 2000, pp. 409-421. https://doi.org/10.1016/S0143-8166(00)00050-6
  12. 추연준, 강보선, "홀로그래피 입자속도 측정시스템의 개발과 분무 액적에의 적용", 한국액체미립화학회지, 제10권, 제3호, 2005, pp. 17-28.
  13. L. Denis, C. Fournier, T. Fournel and C. Ducottet, "Twin-image noise reduction by phase retrieval in inline digital holography", Proc. SPIE, Vol. 5914, 2005, J1-J14.
  14. V. R. Singh and A. K. Asundi, "Amplitude contrast image enhancement in digital holography for particles analysis", Proc. SPIE, Vol. 5878, 2005, pp. 17.1-17.8.
  15. S. Kim and S. J. Lee, "Effect of particle concentration on digital holographic PTV measurement", Trans. of the Korea Society of Mech. Eng. B, Vol. 30, 2006, pp. 929-934. https://doi.org/10.3795/KSME-B.2006.30.10.929
  16. A. K. Jain, "Fundamentals of digital image processing", Prentice-Hall, 1989, pp. 276-284.
  17. S. J. Baek and S. J. Lee, "A new two-frame particle tracking algorithm using match probability", Exp. Fluids, Vol. 22, 1996, pp. 23-32. https://doi.org/10.1007/BF01893303